Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L1 | Accepted-AOC Tender AoC | |
| 2 | L2₹5.4 L+₹4,823 (0.91%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.2 L+₹83,005 (15.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
27 Mar 2023, 6:00 pmClosed
GE(W) HISAR
GE(W) HISAR HISAR MIL STN HISAR 125006
GE(W)/HSR-47/2022-23 REPAIR/MAINT OF LIFTS INCLUDING CERTAIN ALLIED WORKS AT HISAR MIL STN UNDER GE (WEST) HISAR
2022_MES_564125_3
GE(W)/HSR-47/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(W) HISAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE(W) HISAR
₹11,000
Yes
1 Apr 2023
3 Mar 2023
29 Mar 2023
3 Mar 2023
27 Mar 2023
13 Mar 2023
Amount
Routine repair / maintenance of forthnightly, monthly, quarterly for a period of one month for one lift of 08 passengers ( 544kg) capacity with fully automatic electrical operated with microprocessor based control panel, automatic operated sliding doors service ground plus upper two floors (G+2), Make "OTIS' including replacements of minor defective parts like nuts , bolts, control wire , cop's buttons small switches and thimbals etc , installed at at MH Hisar installed complete all as specified and directed of the following capacity lift:- (i) Machine room, incl, electric elevator 8 passengers capacity 544 Kgs lifts = 01 Nos, Make - OTIS
(ii) All as per item No 1.00 above but Machine room, incl, electric elevator 8 passengers capacity 544 Kgs complete all as specified and directed lifts = 01 Nos, Make -OTIS
(iii) All as per item No 1.00 above but Machine room, incl electric elevator hospital stretcher cum passenger cap 1020 Kg lift -01 No ,Make -OTIS Note for item No 1.00 to 1.02 above : (i) The rates quoted shall be inclusive of T & P , scaffolding required for carrying repairs works & stationery required for maintaining or records (ii) Normally maintenance carried out will be in day time , but in case of emergency /breakdown it should be attended at odd hours/night times within 24 hours without any extra cost and rate as quoted aboe shall be deemed to be includive of the same. (iii) In case of break down, the additional manpower if required will be arranged by the contractor ,the rate shall be deemed to be inclusive in the quoted rate (iv) Authorized agency shall carry out regular routine check/preventice maintenance as recommended by manufacturer for the complete system and rectify the minor /major defect noticed immediately. One separate regisgter to be maint as complaint register received from department/user and taking signature from users after rectifying the defects if any. (v) All consumables maintenance materials such as oil, lubricants, grease etc are deemed to be included in the above quoted rate (vi) All the precautions/safety measures against lost/damage shall be borne by the contractor. In any accident occurrence during operations of lift, due to maintenance failure, the contractor will responsible for compensation as applicable to men and material. (vii) One visit at site of representative Authorized agency is manadatory. In case if visit at site not carried out by the representative Authorized agency , the payment of respective month shall not be made.
S&F in replacement Automatic rescue device( ARDL 7/02 ) Main PCB suitable for Otis make passenger lift complete all as specified and directed.
S&F in replacement ARD master card complete all as specified and directed.
S&F in replacement ARD Sealed maintenance free Battery 12V, 7AH or as per existing complete all as specified and directed.
S&F in replacement lock break complete all as specified and directed.
S&F in replacement contactor for drive motor of Cap EPS unto 18.5 KW/IMVF or as per existing complete all as specified and directed.
S&F in replacement contactor LC 1-d186P7 all as per existing complete all as specified and directed.
S&F in replacement LOP (landing Operating Panel) display complete all as specified and directed.
S&F in replacement COP (cabin operating Panel)display all as specified and directed
S&F in replacement Guide Shoes all as specified and directed.
S&F in replacement Limit swith complete all as specified and directed.
S&F in replacement Limit Roller complete all as specified and directed.
S&F in replacement Cabin light LED type of 5W complete all as specified and directed.
S&F in replacement Reed Switch all as specified and directed.
S&F in replacement Door sensor all as specified and directed.
S&F in replacement hanger Roller all as specified and directed.
S&F in replacement Door Locking Device System complete all as specified and directed.
S&F in replacement Door eccentric rooler complete all as specified and directed.
S&F in replacement Control box for lift complete all as specified and directed.
S&F in replacement cross flow air blower Model No- MCBH 1031L/2L-E3 complete all as specified and directed.
S&F in replacement electronic hooter complete all as specified and directed.
S&F in replacement Digital Display card complete all as specified and directed.
M/s Devendera construction
fauji electric works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .