Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.3 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Quoted rates lowest and competitive | |
| 2 | L2₹99.8 L+₹2.4 L (2.50%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 3 | L3₹1.0 Cr+₹5.0 L (5.16%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 4 | L4₹1.2 Cr+₹24.3 L (24.9%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 5 | Rejected-Technical BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | - | Rejected-Technical NR, as not enlisted in requisite cat a (i) |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
15 Sept 2020, 6:00 pmClosed
COL PRADEEP SHARMA, CWE DELHI CANTT
HQ CWE DELHI CANTT-10
PROVN OF MES POWER SUPPLY, WATER SUPPLY AND EXTERNAL SERVICES FOR NEW LINE DATA CENTRE (NLDC) NFS NODE IN DELHI, UNDER GE (NORTH) DELHI CANTT
2020_MES_364536_2
CWE/D-25/2020-21
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE NORTH DELHI CANTT
₹1.9 L
Yes
5 Oct 2020
29 Aug 2020
16 Sept 2020
29 Aug 2020
15 Sept 2020
3 Sept 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc.n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft / loose soil, complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
M&L for reinforcement cement concrete design mix M-25 (20mm graded aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases forcolumn etc, complete all as specified and directed.
M&L for reinforcement cement concrete design mix M-25 (20mm graded aggregate) as in column , pillars, piers, posts and struts, complete all as specified and directed.
M&L for reinforcement cement concrete design mix M-25 (20mm graded aggregate) as in Beams cantilevers, bressummers, lintels over 1.50 m span, complete all as specified and directed.
M&L for reinforcement cement concrete design mix M-25 (20mm graded aggregate) as in chajjas, complete all as specified and directed.
M&L for reinforcement cement concrete design mix M-25 (20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings and in shelves and the like, complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of column, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work vertical or to batter for rough finished flat surfaces of concrete, complete all as specified and directed.
Form work to sides of pillars, posts struts, piers, columns and stanchions for rough finished flat surfaces of concrete, complete all as specified and directed.
Form work to sides and soffits of floor or roof beam, beam haunchings, girders, bressum-mers, lintels, cantileverrs, shelves including supports, overhangs, etc also splays between floors and beams etc.for rough finished flat surfaces of concrete, complete all as specified and directed.
Form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete, complete all as specified and directed.
Mild steel bars(TMT) 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooking for columns hooking ends and binding with and for and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
All as per item No 12, but 5 mm dia and over upto and including 10mm dia in stirrups, spacers & binders, complete all as specified and directed.
Form work to soffits of suspended slab such as roof slabs, floor slabs and similar work; n. exc 200mm thick(horizontal or sloping), complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft to loose soil, complete all as specified and directed.
Removing excavated material exc. 500m and n exc. 1000m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on fair/un-even surfaces of brick work or concrete surfaces to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) on fair/un-even surfaces of brick work or concrete surfaces,using water proofing compound to be finished even and smooth without using extra cement, complete all as specified and directed. (WPC measured separately)
M&L for 5mm thick rendering in CM (1:3) on ceiling fair/un-even surfaces of brick work or concrete surfaces to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces as in ceiling including preparation, complete all as specified and directed.
M&L for preparation of new plaster surfaces and applying two coat of cement base paint over alkali resistence primer on wall complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces of wall including preparation, complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 100mm thick cement concrete type D-2 1:4:8 (40mm graded agg) as in sub floor; complete all as specified and directed.
M&L in repair for machine cut kota stone slab flooring 18-to -20 mm thick over and including bedding layer 20 mm thick in cement mortar 1:6, pointed & jointed in neat cement slurry mixed with pigment to match the shade of the slab including grinding and polishging etc complete as directed and specified.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair without using extra cement all as directed and specified
S & F for precast reinforced cement concrete covers slab in 1:2:4 using 20 mmgraded stone agg and set in CM 1:4, complete all as specified and directed.
S & F aluminium powder coated three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below :-- (a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 21447) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 21446) (c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.50 (Section No 21455) (d) Interlock Section of Shutter shall be be of size 18.00 x 40.00 x 1.50 (Section No 21454) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.50 (Section No 20844) Note:-(i) Section Number given above are of make Jindal, Contractor may use similar section of other make
S & F Steel rolling shutters 1 mm thickness, without ball bearing, as specifioed including top cover , anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete : push pull or manual type, complete all as specified and directed.
S F Safety lever locks mild steel with 4 levers for rolling shutters, complete all as specified and directed.
S & F ball bearing for rolling shutters, complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L DPC 40 mm with PCC (1:2:4) type B2 Using water proofing compound, complete all as specified and directed.
M & L for APP polymaric water proofing membrane minimum 3mm thick and weighting not less than 3.6 kg / sqm of black finished reinforced with non woven polyster matt,with fusable finish laid over compatable bitumen 85/25 gde @ 1.20 Kg/Sqm over bitumen primer at the rate of 0.40 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and 100 at the ends and sealing incl applying a coat of cold emulsion bituminous primer all as per manufactur's instructions incl preparation of surface and including 15 mm thick cement scrred bed in CM 1:4 complete all as specified and directed.
M&L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the sub structure in contact with backfill to bemeasured) complete all as specified and directed.
M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L Treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall complete all as specified and directed.
Supply only Liquid integral water proofing compound complete all as specified and as directed.Make: FOSROC.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc. 0.50 cum, getting out , returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc. 50 m and making good surface, complete all as specified and directed.
M&L for cement concrete (1:2:4) using 20mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes confirming to I.S.1161-1998 grade St-240 complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified and directed.
M & L for providing precast cement concrete type B1 (1:2:4) block masonary with solid blocks exc 10 cm in with and set in CM (1:4) all as spd and directed
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M & L Sand filling under floors or in foundations including watering and consoilidation complete all as specified and directed.
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 grade with Grey cement and pigment complete all as specified and directed.
Rolling and consolidating formation surfaces with power road roller of 8 to 12 tonnes complete all as specified and directed.
Rolling and consolidating of brocken boulders not exc 15 cm thickness with power road roller of 8 to 12 tonnes complete incl watering and levelling all as specified and directed.
S&F rolled mild steel Fe-410W (Gde-E-250) quality 'B'Roof trusses (framed ) , trussed, purlins, crane gantries , rails and fastening and havy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified and directed.
S&F Pre-Painted galvalume aluminum zinc coating coloured GI based Plain steel sheet 0.50 mm thick having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
S F for Hand rails, half round or other stock section or core for wooden hand -rail straight portion, drilled and countersunk for ballusters, nosing to steps including embeding in concrete and screwing etc. Wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling , bolting or riveting etc. and similar work confirming to Fe -290 Gde E-165 complete all as specified and directed..
Supplying, laying and testing of 100mm dia DWCPE pipe laid in trenches, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching and coping of manholes etc including necessary form work, complete all as specified and directed.
M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs, complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes, complete all as specified and directed.
M&L 40 mm thick plain cement concrete 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in floors finished even and smooth using extra cement , complete all as specified and directed.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4, complete all as specified and directed.
M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in copings,Bed blocks,and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L extra for forming fair finished drain or channel exc. 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
E/M WORKS : Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, for light/fan point PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed.
Description all as per item No 65 above but one 5 Amps 3/5 pin socket outlet on same board with other switches, complete all as specified and directed.
Description all as per item No 65 above but with using 4 sq mm PVC insulated multi-stranded copper conductor for independent switch socket outlet 6 pin 5/15 Amps and incl 2.5 sqmm PVC insulated multi-stranded copper conductor single core as earth continuity conductor wire, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way 230 Volts,ISI marked, complete all as specified and directed.
S&F Switch piano flush type 15/16 A single pole one way 230 Volts, complete all as specified and directed.
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volts, complete all as specified and directed.
S&F Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 Volts, complete all as specified and directed.
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete, complete all as specified and directed.
S & F in repairs Sheet metal enclosure DB ,8 way single door type,single pole and neutral with 200 Amps rated bus bar,230 volts, including connecting all connections of wire to MCBs with proper lugs & arrangements complete all as specified.
S&F in replacement MCB, DP, 32 Amps,240 Volts, AC of breaking capacity 10 KA C curve, complete all as specified and directed.
S&F in replacement MCB SP 240 Volts AC 6 - 40 Amps of breaking capacity 10 KA C curve, complete all as specified and directed.
Supply and fixing surface mounted mounted type LED panel type 34 Watt 4ftx1ft complete with module,driver and all accessories 3 core copper wire for connection complete all as specified and directed.
Supply and fixing Ceiling fan 1400mm sweep BEE 5 star rating,suitabale for SP 230V, 50 Hz, AC supply including fixing of fan regulators and down rods and connecting up with 3 runs of 1.5 sqmm single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors connected from ceiling rose to fan complete all as specified.
Supply and fixing Exhaust fan 300 mm sweep suitabale for SP 230V, 50 Hz, AC supply complete with louvers shutters including fixing/grouting of frame in wall and cutting opening, complete and connecting with and including 3 Nos 1.5 sqmm single core, PVC insulated but unsheated, FRLS cable with multistranded copper conducctors from ceiling rose to fan complete all as specified.
Supply and fixing New street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including with suirable size GI bracket with MS clamps, nut and bolts complete all specified and directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised iron wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per item No.81 but Hard/dense soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply and laying galvanised steel water tubing 40mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow,tees,short pieces,connectors,caps,plugs and unions,etc) and fixing complete with clips,wall hookswooden plugs,or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required complete all as specified and directed.
All as per item ser No 85 but 20 mm dia, complete all as specified and directed.
Supply and fixing gunmetal gate valve 40mm dia screwed down high pressure with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
Supply and fixing gunmetal gate valve 20mm dia screwed down high pressure with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
M&L for Construction of valve chambers 900 mmx900mmx900 mm with 15 cm thick solid concrete block masonary,block casted using PCC 1:3:6 type C-1mix built in cement and sand mortar 1:4,15 mm plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick,MS sheet cover 3.15mm thick including 50x50x6 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1,with 25x6 mm flat iron hold fast,handles,hinges with locking arrangments, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in type of soil, complete all as specified and directed.
M&L for cutting the existing pipe line 80/100 mm dia and fixing the suitable tee 80x40x80/100x40x100 mm dia and all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed.
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm , as specified and directed
Supplying, laying, connecting, commisioning and testing HT Cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electrical power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed), cross sectional area 95 Sq mm 3 core, laid in trenches/fixed to pole/passing through pipe, ISI marked as per IS : 7098 ( Part-2 ) complete with all as specified. (Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under relevant items).
M&L for cable jointing kit Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm 3 core complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm 3 core complete all as specified and directed. Note for Item No 95 & 96 : - Make - M-Seal/Raychem.
Supply and laying, testing and connecting in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core, laid in trecnhes or fixed to pole/wall complete all as specified and directed.
M&L for Steel Tubular Pole 410 SP-31 (9 metres long) complete with cast iron base plate, finial taper plug, nuts, bolts and washers all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (c) Providing PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation including necessary form work with cement mortor 1:4 for plinth block/collar above GL all as specified and directed. (d) The complete embedded portion shall be painted with two coats of black bituminus paint. Painting of Poles with two coats of aluminium paint over a coat of red oxide primer in full length of pole. Black and yellow strips up to 1.5mtr over a PCC coping alternatively including numbering the pole complete all as specified and directed. Make : - National Tubing Co Kanpur/Bharat Coduit & Steel Works, Kanpur/C&S Electric/Shivam Metals.
Supply, Install , testing and commissioning of Street Light panel, single phase,frame size 1, 6KW with digital 24 Hr.timer,32 Amp TP Contactor, 40 Amps SPN MCB incl necessary cable lugs, glands complete all as specified and directed. . Make Havells Cat Part No IHXSS01060 or Indo asian/L&T
M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape complete all as directed and specified .
M&L for PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection complete all as specified and directed.
M & L for steel tubes, light grade galvanised 100 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed.
All as per item No 102.00 but 32 mm bore.
Supply and fixing New street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt complete all specified and directed
M&L for loop box out door type made out of Engineering plastic one piece moulding type,Bus bar rating 63 Amps 2 strips aluminium with bus bar mounting colour R,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size 200x150x100 mm with 6 Amps MCB SP, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed.(Note:- Suitable size Lugs,Glands rate deemed to be included) (Make- Universal switch gear control/Unilac)
Boring under roads without disturbing the top surface of road for passing through the cables with 100 mm dia HDPE pipe complete all as specified and directed. (Note : 1. Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost. 2. HDPE pipe shall be measured and paid separately under relevant items).
M&L for 100 mm dia HDPE pipe PN-10 with fittings laid in trenches/wall for protection of underground cable when crossing the road/fixing on wall as in repair and all as specified and directed(Make : Supreme/Prince).
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4 mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed .
S & F earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 4mm dia galvanised iron wire. All as per specified and directed.
Material & labour for earthing with Copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20X3 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed.
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20x3mm copper strip all as specified and directed.
Supply, Installation, Testing and Commissioning of 11kV, 630A, 21kA,SF6 Insulated, Motorized, Indoor type, Non extensible, 3way RMU one incoming two out goings with 1No. Load Break Switch (LBS) + 2Nos Vacuum circuit breaker (VCB) with Air Insulated Metering Unit (M) connected to Bus and common item & accessories for RMU as per the following:- (i) Technical general characteristics : Metalclad Compact Switchgear SF6 insulated type, Protection degree- IP4X , Suitable rating copper bus bar for Main and earth system, SF6 Tank Material Stainless Steel type with provn of standard interlocks. (ii) Applicable for IS codes: as per IEC 62271-1, IEC 62271-100, IEC 62271-200 for Common Clauses AC Circuit Breakers, HV Switchgear & Controlgear,Metal Enclosed Switchgear. (iii) Electrical Characteristics : Main Circuit Service voltage 11kV, Rated voltage 12kV, Power frequency voltage withstand 28kV, Impulse Voltage withstand 75kVp, Rated Current Circuit Breaker 630A, Rated short-time current 21kA for 3s Rated Short circuit making current 52.5kA, Frequency: 50Hz (iv) Load Break Switch (LBS) Feeder Comprise of following:- 11kV, 630A, 21kA, Motorized Operated load break switch with built-in earth switch, Mechanical position Indicator (ON/OFF/EARTHED), Live cable Indication, Cable termination bushing suitable for cable size upto 3Cx 300Sq mm XLPE cable with Cable termination cover boots (Push on type) (v) Vacuum Circuit Breaker (VCB) Feeder Comprise of following:- 11kV, 630A, 21kA VCB with Motorized Spring charging mechanism & trip & closing coil for operation, Manually Operated 630A disconnector with built-in earth switch, Mechanical position Indicator (ON/EARTHED), CT with ratio (200-100/1-1A) / (300-150/1-1A), 2.5VA, CL-5P 10 for Protection and 2.5VA, CL-0.5 for metering, Self-Powered 3O/C+1E/F Relay (C&S Make – CSPR-V5), Multifunction meter (Secure make Elite-443 or Equ.) 1No, Live Cable Indication, Cable termination bushing suitable for size upto 3Cx300Sq mm XLPE cable with Cable termination cover boots (Push on type). (vi) Air Insulated Bus Connected Metering Unit (M):- Air Insulated enclosure with necessary Bus connection 1No. 2 PT 11kV/√3 / 110V/√3, 25VA, CL-0.5. (vii) Common Items & Accessories for RMU :- Manometer with Green & Red zone for indicating pressure of gas inside the tank fitted on RMU, Battery charger,7Ah (I/P-230V AC, O/P-24V DC) , Operating Handle (Supplied Loose with RMU) Make- C&S/ABB/Schnieder Note:- (a) Necessary earth work, PCC work, fair cement finishing for fixing of floor mounted RMUs inside the sub stn and other misc works etc, required for fixing of eqpt are deemed to be included in the unit rate coated by the contractor. (b) Any other parts/items not specified abaove but have been considered essential for smooth and safe functioning of the compact VCB system shall be included in the items and are covered against the quoted rate. (c) The installation & testing shall be carried out by service engineer of manufacturer of VCB only. (d) All the instrucments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates.
M&L for cable route indicators comprising of cast iron disc 100mm & 3 mm thick with angle iron 25x25x3mm & 30 cm long with GI bolt & nut embedded in the ground in route of the cable in PCC 1:3:6 complete all as specified and directed
SANJEEV ENTERPRISES
The new hut furnitures
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .