Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 214 2ND FLOOR SAMRUDDHI COMMERCIAL PREMISES CHINCHOLI BUNDER ROAD MINDSPACE MALAD WEST MUMBAI MAHARASHTRA 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical TECHNICALLY DIS QUALIFIED |
| 4 | Rejected-Technical A 101 VAKRATUNDA APARTMENT G M ROAD TITWALA EAST THANE 421 605 | TITWALA | THANE | MAHARASHTRA | 421605 | Rejected-Technical TECHNICALLY DIS QUALIFIED |
| 5 | Rejected-Technical 173 SHAMLI SHIV VIHAR RAIL PAR SHAMLI UTTAR PRADESH 247776 | SHAMLI | UTTAR PRADESH | 247776 | Rejected-Technical TECHNICALLY DIS QUALIFIED |
Tender Value
Refer Docs
EMD Value
₹16,790
Closing Date
4 Oct 2021, 10:00 amClosed
Project In-charge
Dredging Corporation of India Limited, Flat No.F2-B2, Sector 10, Juhu Nagar, Vashi, Navi Mumbai - 400703.
RENOVATION OF DCI OWNED FLAT Nos.F2 B1 AND F2 B2 AT RAINBOW APARTMENTS SECTOR 10 JUHU NAGAR VASHI NAVI MUMBAI
2021_MoS_649092_1
DCI/RO-MUM/HR/VASHI FLATS/2021-22
Open Tender
Civil Works
Works
60 days
Vashi, Navi Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹295
Yes
DCIL
₹16,790
Yes
Vashi, Navi Mumbai
28 Dec 2021
20 Sept 2021
4 Oct 2021
20 Sept 2021
4 Oct 2021
20 Sept 2021
25 Sept 2021
Amount
REPAIRS TO BUILDING
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1cement: 4 coarse sand): F2-B1 & F2- B2 Apartment
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge.
F2-B1 & F2-B2 Apartment
DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead :Thickness above 40 mm up to 75 mm
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form work for :
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
FLOORING
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
F1-B1 2bhk Apartment
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Size of Tile 600x600 mm
FINISHING
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
F1-B1 2bhk Apartment
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
F1-B1 2bhk Apartment
SANITARY INSTALLATIONS
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipefor back and front flush with standard spreader pipes with fittings, G.Iclamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required
Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
F1-B1 2bhk Apartment
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
15 mm nominal dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape 1500x450 mm
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing soil, waste and vent pipes :
100mm dia
100 mm diameter pipes Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
75 mm diameter :
Centrifugally cast (spun) iron socketed pipe as per IS: 3989
WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing brass bib cock of approved quality :
15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
150 mm diameter
WATER PROOFING:
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. persqm of area. (iv) IVthcourse of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
NEW TECHNOLOGIES AND MATERIALS
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In- Charge
25 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter
Bars above 12 mm diameter
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge
Upto and including 12mm dia.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-Incharge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge
12 mm average thickness.
NON SCHEDULE
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and Plastering with premixed readymade cement mortar such as 'READYPLAST' of Ultrech or 'EASTPLAST" of wall plast Products Pvt. Ltd or Equivalent, manufactured in automated dry mix batching plant where cement, sand and polymer additive are mixed in pre-determined ratio (as per manfacturerspecfication). in one coat 6 to 7 liter potable water (as per manfacturespecification ) shall be added to 40kg of readymix dry mortar on mortar mixing G.I tray and shall be mixed well for 4-5 minutes. The mortar shall be left undisturbed for 3-5 minutes to dissolve additive and shall be mixed once again to form cohesive and consistent mix.
12mm average thickness
Jacketing with MICROCONCRETE (Dr. Fixit, BASF, FOSROC or equivalent brand) including making hole in RCC slab, if required and as approved by the Engineer - in - charge, for pouring the concrete in shuttering nould of jacket excluding the cost of reinforcement, bond coat, shear key, centering, shuttering and finishing at all floors and at all leves etc. complete as per the direction of Engineer - in Charge.
In Columns, Pillars, Beams and walls (Any Thickess)
Providing and laying in position cement concrete in sunken floors at all floors at all levels excluding the cost of centring and shuttering - 1:5:10 (1 cement : 5 coarsed sand :10 graded brick aggregate 40mm nominal size)
ELECTRIFICATION
Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.With suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. With suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing following way SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, inter connections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
2 + 8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supply of surface mounted 4' LED linear fitted with 1 No. of high efficiency LED linear lamp of wattage not more than 20W, having colour temperature not less than 6500K, system lumen output not less than 1600lm CRI not less than 70 made of CRCA housing, , with buit in electronic driver, mounted directly on wall/ ceilinig, including connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (Fans will be supplied by DCI)
WINDOWS AND DOORS
Main door shutter repair, replacement of existing lock with Godrej make lock, door all drop replacement & handle replacement (aluminium door shutter accessories of BIS standards) and if any accessories damaged to be changed, including transport, men & materials fixing & finishing charges.
Flush wooden door shutter of 30 mm thickness BIS standard company make with all accessories like aluminium handle, all drop, tower bolts, hinges etc extra with MS U frame of angle 1 ½ “ X 3 ¼ “ with wall thickness 6 mm including transport, men & materials fixing & finishing charges.
UPVC frame with two track two equal panels sliding window frame with plain glass of glass thickness 6 mm as per BIS standards, UPVC section size as per BIS standards including transport, men & materials fixing & finishing charges. (Window size 900 mm X 900 mm of 2nos).
UPVC frame with four track four panels sliding window equal parts with plain glass of glass thickness 6 mm as per BIS standards, UPVC section size as per BIS standards with five tracks, one track for stainless steel mesh shutter 5 of 1 (1 sq mm cross section) including transport, men & materials fixing & finishing charges. (Window size 3300 mm X 1400 mm).
UPVC frame with three track three panels sliding window equal parts with plain glass of glass thickness 6 mm as per BIS standards, UPVC section size as per BIS standards with four tracks, one track for stainless steel mesh shutter 4 of 1 (1 sq mm cross section including transport, men & materials fixing & finishing charges. (Window size 1750 mm X 1000 mm).
UPVC Toilet door shutters with U frame as per BIS standards with all aluminium accessories like handles, hinges, tower bolt, all drops etc including transport, men & materials fixing & finishing charges. (Door size 750 mm X 1950 mm of 2nos).
UPVC Toilet ventilators with exhaust fan(size 200 mm X 200 mm) with louvers glassincluding transport, men & materials fixing & finishing charges. (Ventilator size 550 mm X 600 mm of 2nos).
KUMAWAT INFRASTRUCTURE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .