| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.3 L+₹1,396.83 (0.04%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.5 L+₹2.3 L (6.06%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹42.1 L+₹4.8 L (13.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹43.6 L+₹6.4 L (17.2%)Rejected-Finance BX 167 4 ISHWAR NAGAR PATHANKOT PUNJAB 145001 UDYAM PB 16 0001334 03AALFR1593C1ZE B R | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.6 L
EMD Value
₹87,240
Closing Date
7 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
SPECIAL REPAIR TO ELECTRICAL DISTRIBUTION SYSTEM AT POWER HOUSE AT AIR FORCE STATION THOISE UNDER GE(AF) THOISE
2023_MES_573922_1
GEAF/T-38/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GARRISON ENGINEER (AF) THOISE
As per Tender Document
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹87,240
Yes
21 Apr 2023
10 Jan 2023
9 Feb 2023
10 Jan 2023
7 Feb 2023
24 Jan 2023
Amount
Supply , installing, testing and commissioning of LT Grid/ PLC Panel incl Taking down the old Unsv Panel with locking arrangement vermin/ dust/ weather proof, self ventilation on suitable interval on both side, totally enclosed, AL bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint, 415 volts, TPN, 50 Hz grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and directed compprising of following accessories. Make of Panel :- Seimens,Schneider, L&T, ABB. Note :- Panel should be CPRI approved including plc & HMI with following specification (i)PLC ,CPU,Ext.Memory,Including software development PN, DP:- 1 Central processing unit for the low and medium performance rangeof the central and decentralized control, programming by means of FBD, LAD, STL in accordance with IEC 61131-5, SCL, CFC, processing times (bin.) 0.05 μs and (floating point arithmetic) 0.45 μs, 256 counters, 384 kB RAM, data blocks 1024, address range 2 kB, 16.384 digital inputs and outputs and 1024 analog inputs and outputs can be parameterized, can be expanded to up to three module racks, operating hours counter, process diagnosticsmessages, start-up function, control of variables, diagnostics buffer with up to 500 entries, routing function, interfaces MPI and DP
master, buffering by means of MMC, Profinet CBA communication, hardware clock (real time), CE, UL, CUL, CSA and C-Tick certification, approvals according to EN 55011, EN 60079-15, EN 61000-6-2/ -4, IEC 60068-2-6/ -27/ -29, IEC 60721-3-2/ -3, IEC 61000-4-2/ -3/ -4/ -5/ -6, mm, including sectional rail for mountingmodules as required and Micro Memory Card 2 MB, supply and mount ready-to operate :- 1 Nos Make L&T / proface / Seimens/Schneider/ABB (ii) HMI for DG Panel: Multiple window for dg for all parameters, operating and monitoring DGs,use as thin client for terminal services, remote maintenance and services via the data OPC interfacing to different manufacturers, display of HTML documents, with pixel-graphics 10.4" TFT- touch display with background lighting, 65536 colors, resolution 640x 480 pixels, MTBF 50000 h, Windows CE operating system, ARM CPU, mouse andcurve functions and bar display, calculation functions, external evaluations with Excel and MS Access, input/output fields, configurable buttons with 16 functions simultaneously, online evaluation using characteristics, Visual Basic Scripting, signalling system with different alarm/message classes, message buffer for 512 entries, 500 process images, 50 archives per project, 10000 entries per rchive,recipe memory for 300 recipes,10 user groups can be set, password protection, 16 online. languages, multi media card data carrier support, time interrupt function for cyclic function processing,display of graphics, bars, predefined texts, buttons. Integrated signalling system with 4000 messages, remote download for configuring USB, MPI, Profibus DP, Ethernet, Modem, http and SD/Multi Media Card, degree of protection IP65 on the front, according to IEC 60068-x, IEC 6199-4-x, IEC 61131-2, including operating instructions, Compact Flash card, back-up battery; supply and mount ready-to-operate (a) Gprs/Rf option for remote monitoring of complete DG (b) Provison of auto AMF start command. (c) Opening and closing of DG (d) Phase indicator R,Y,B - 1 SET
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a hard/dense soil complete all as specified and directed by Enginer-in-Charge.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L in replacement for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed by Engr-in-Charge. Note:-Excavation and earth work to be measured and paid for separately
Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness of 18 cm shall be measured for payment purpose.
M&L in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engr-in-Charge.
M&L in repair Earthing complete with copper plate elecrode of size 60×60cm×3.15mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth 20×3mm copper strip by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of copper strip wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to spoxsed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) Note : (i) Excavation work should be done by manpower only. (ii) Earth test should be done by contractor and if required result is not found entire earthing should by contractor again with no extra cost to the Government.
Ms Salaria Builders
NEERU ELECTRICALS
M/S NINDI BUILDERS
M/S RUDHRAKSH TRADING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .