Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹15.6 L+₹2,355 (0.15%)Rejected-Finance VILL PO PS BELLATORE DIST BURDWAN PIN 722 203 WEST BENGAL | BELLATORE | BURDWAN | WEST BENGAL | 722203 | L2 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 3 | Rejected-Technical OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | - | Rejected-Technical NOT ENLISTED IN REQUISITE CATEGORY SO NOT FULFIL NIT CRITERIA |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARVIND KUMAR SHARMA IDSE SE CWE (AF) OANAGARH
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
REPAIR/MAINT OF HT NETWORK SYSTEM AND ALLIED INSTALLATIONS AT AF STATION PANAGARH UNDER GE (AF) PANAGARH
2023_MES_605463_1
82407/pan/e8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PANAGARH
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) PANAGARH
₹34,000
Yes
31 Oct 2023
24 Jun 2023
29 Jul 2023
24 Jun 2023
22 Jul 2023
8 Jul 2023
26 Jun 2023 - 3 Jul 2023
Amount
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
Testing and calibration of HT VCB 33/11 KV complete with primary and secondary test as required including overhauling, decaling and smoothening spring mechanism, checking of wiring of all electrical measuring instrument and rewiring as per existing cable size and colour, resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type of fault developed in feeders including checking of bus bar complete all as specified and directed by Engr in Charge. Note:- Contractor will submit primary and secondary test record at the time of calibration of HT VCB, TR control panel. The rate quoted by tender shall deemed to include the cost of this provision incl T&P required for injecting regulated high current.
Testing and commissioning of 5 MVA Transformer and its interconnection of remote tap changer panel and differential including minor repairs and checking of control cables, Circuits etc by Licensed agency for carrying out following tests :- (a) Insulation resistance of the winding between phases and between Individual phases and earth on both HV and LV sides and also between HV and LV windings. (b) Winding resistance. (c) Dielectric strength of transformer oil before and after filtration/dehydration. (d) Voltage ratio test at all tap positions. (e) Polarity test. (f) Operation of Buchholz relay. (g) Proper functioning of all protective relays. Note : (i) The contractor has to submit full report of all the Tests carried out in Triplicate to Engr-in-Charge. (ii) All the necessary T&P and test equipments to be arranged by contractor and deemed to be included in the quoted rate.
Note for srl item 1&2 :- (i) Spare parts will be measured and paid for separately under respective items/Prime Sum cost and if copper wire and ferule required for wiring include in this items. (ii) For testing and calibration of new relays in replacement will be measured and paid separately under respective items. (iii) The calibration and servicing shall be carried out by the experienced person from OEM and prior approval shall be obtained from Engr-in-Charge..
Repair/Overhauling of motor drive mechanism Gang Operated Panel for 33/11 KV VCB/bus coupler of existing make, type, size, capacity, with driving gear and springs including rewiring of Panel & Motor complete all as directed and specified.
Dismantling, Repair, Overhauling and testing Current Transformer 33KV, single phase Outdoor resin cast, ratio 200-100/1-1-1A , Three core, one metering (Burden- 15VA, Accuracy class- 1.0 and two protection core (Burden- 15VA, Accuracy class- 5P and PS class, Vk ≥ 300V at lower ratio, Ie < 30 ma at Vk/2 in lower ratio, Rct < 10 Ω at higher ratio) insulation level 36 KV / 70 KV / 170 KV(P) as per IS-2705 including filtration & dehydration to make satisfactory serviceable all as per existing make and directed by Engr-in-Charge.
Dismantling, Repair, Overhauling, testing and commissioning 33KV, single phase, out door oil cooled Potential Transformer of ratio 33KV/√3/110V/√3/110V/√3, class 0.5-3, burden 50VA-50VA.. including filtration & dehydration all as per existing make and directed by Engr-in-Charge.
Preparing old painted surfaces of HT VCB/Bus coupler/LT Panel of any make and type and applying two coats of synthetic enamel paint by spray painting including marking HT feeder SM/MES No all as specified and directed.
S&F PVC insulated and PVC sheathed cable galvanized steel stip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 12 core 1100 volt grade incl taking out old cable of any size and type complete all as directed.
M&L for compression/crimping type sleeve joints for jointing conductors/jumpers connections above 10mm dia of conductors wire overall including treatment with conducting jelly complete all as specified.
Supply and install HT 33 KV out door type gang operated air- break switch suitable for horizontal or vertical triple pole, mechanically operated, mounted on double stack type insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 amps. As per existing sample and directed by Engineer in charge.
Supply and Fixing Lightning Arrestor HT 33 KV 65 KA expulsion type including taking down old unserviceable lightening arrestors complete all as specified and as directed
S & F drop out fuse channel type fitted on two post insulator per pole per phase complete with FRP fuse barrel vertical type connected with necessary nut bolts brackets including testing confirming to IS 9835 rating 12 KV, 400 Amps made of Gun Metal complete all as directed.
Supply and laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 120 sq mm. complete all as directed.
Supply and fix cable jointing kit for 33 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sq mm. complete all as directed.
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
M & L for painting with two coats of DUCO enamel paint of ICI brand of approved colour over a coat of red oxide metal primer after scrapping thoroughly the existing corroded paint, dirt/dust, oil and grease from the steel surface of the transformer complete. (a) 5 MVA transformer (33/11 KV)
Surface excavation not exceeding 15 cm deep complete all as specified and directed.
M& L for 63 mm thick graded gravel 20 mm to 40 mm packed in 33 or 11KV outdoor sub stn yard all as specified 10 mm deep
Material and labour for excavating in trenches not exc 1.50 mtr wide but exc 1.50 mtr depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed.
Returning filling in soft/loose soil, including, spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. (NOTE : The top of filled trench shall be made proud by using the excavated soil to cater for subsequent settlement of soil).
Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches all as specified and directed by the Engr-in-Charge
Supply and laying reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for earthing with galvanised earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32x6 mm dia by means of nut, bolts and washers made out of galvanised iron mild steel and 50 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover PCC cover lab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete. NOTE : The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 20 x 3 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover RCC cover lab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete. NOTE : The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station..
M & L for Danger Notice plate of 1.6mm thick MS sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 25 x 20 cm size complete all as specified.
S&F disc type Insulator ( three disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 33000 volt grade complete.
S&F Pin type Insulator Double stack type porcelain vitreous, white brown or green ball and socket type with tension clamp galvanized iron nut for conductors working pressure 33000 volt grade complete.
Supply & filling the new transformer oil of rupturing capacity 50KV for 60 Sec for topping up to required level of transformer with approved make. Note- Dehydration of transformer oil deemed to be include in the item rate.
Filtration of the existing transformer oil of any make of transformer and capacity upto required dielectric strength as per IE rules and refilling in the transformer upto required level complete.(The deictic strength should not be less than 50 KV after filtration process) . Note- Dehydration of transformer oil deemed to be include in the item rate.
Supply & Spray of agricultural based chemical (Hrbiside) inside the installation to control the growth of unwanted herb etc incl cleaning of the grass herbs bushes etc from the installation , complete all as specified and as directed by Engrs-In-Charge.
Cutting of grass/brushes at 2/4 pole structures and compact sub stations/near transformers in 5 meter perimeter/inside fencing area with help of brush cutter/hand tools , complete all as specified and as directed by Engrs-In-Charge.
M & L for painting with two coats of DUCO enamel paint of ICI brand of approved colour over a coat of red oxide metal primer after scrapping thoroughly the existing corroded paint, dirt/dust, oil and grease from the steel surface of the transformer complete. (a) 5 MVA transformer (33/11 KV)
Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside all as specified
M & L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed.
Prime cost Sum : The prime cost is to used as directed by the Accepting Officer vide condition 1 (v) and 5 of IAFW-2249 of General Condition of Contract forming part of the tender documents. (a) Supply of spare parts for33 KV setup/installations and control system will be decided after dismantling and ordered convening BOO of the Accepting Officer (b) Contractor quoted rate shall be included for overhead and profit and insert amount to cover all However, quoted amount shall not exceed 15% (Fifteen percentage) of estimated amount . In case the contractor quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% add the amounted quoted shall be corrected accordingly to work out the contract sum
Notes :- (i)To exucute the work in all respect, the Contractor shall arrange suitable type of hydraulic/telescopic ladder for easy access to carry out the total work for such height as specified at his own and the quoted unit rate shall be deemed to include for the same. No extra claim will be admissible on this ground. (ii) The Quoted sum shall be arrived at after deducting amount of “Sch of Credit” from the total amount of the ‘BoQ’
KMT INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .