Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 CrAccepted-AOC | ₹13.4 Cr Quoted ₹13.5 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹14.0 CrRejected-Finance | ₹14.0 Cr | L2 | Rejected-Finance Being other then lowest bidder |
| 3 | L3₹18.2 CrRejected-Finance 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | ₹18.2 Cr | L3 | Rejected-Finance Being other then lowest bidder |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
16 Sept 2022, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVN OF UNDERGROUND FSC AT MALARI
2022_MES_513961_3
CEBZ/PGH/T-34 OF 2021-22
Open Tender
Civil Works
545 days
MALARI
AS PER TENDER DOCS
8 documents required · 8 mandatory
₹3,000
GE 871 EWS JOSHIMATH
₹7.1 L
Yes
22 Jul 2023
1 Aug 2022
24 Sept 2022
1 Aug 2022
16 Sept 2022
3 Sept 2022
2 Aug 2022 - 16 Aug 2022
Amount
Sch 'A' Part I (Building Work) Construction of BLOCK OF Sentry post complete all as specified and directed and as shown on drawings.
Construction of BLOCK OF UNDER GROUND FSC BUILDING including surrounding RCC retaining wall with columns, ramps, and staircase etc complete all as specified and directed and as shown on drawings.
Construction of BLOCK OF Generator Shed complete all as specified and directed and as shown on drawings.
Total amount of Sch 'A' Part II A (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
SCHEDULE 'A' PART-II B (INTER WATER SUPPLY)
S & F for brass chromium plated, angle valve, fancy type, 15mm dia complete all as specified and directed.
Total amount of Sch 'A' Part III -A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
S & F LED slim square panel light fitting, 36 watt 2 x 2 feet edge-lit luminaire suitable for arm strong / grid ceiling / recess mounting including connected with 3 core 23 / 0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
S & F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S & F 9 watt LED bulb cool day light, 230 / 240 V AC complete all as specified and directed.
S & F DB TPN 6 Way vertical type with single / three phase outgoing with provision for MCCB 3P as incomer, 415 volt with 200 Amp rated bus bar complete all as specified and directed.
S & F DB TPN 8 Way vertical type with single / three phase outgoing with provision for MCCB 3P as incomer, 415 volt with 200 Amp rated bus bar complete all as specified and directed.
S & F MCCB 100 Amps and 25 KA 3 Pole 415 Volt ICS=100% ICU complete all as specified and directed.
S & F MCCB 125 Amps and 25 KA 3 Pole 415 Volt ICS=100% ICU complete all as specified and directed.
M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following. Note : 1. Point wiring should be carried out on surface mounted rigid PVC conduit or casing-caping on existing RCC beam, column, roof or false ceiling. 2. Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. 3. Modular Metal flush box, modular plate and frame, Switch, socket, regulator, bell push will be measured and paid under respective item. Contd.....
(a) One light point point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) All as per item no 9 above but one light point controlled by two way point wiring with two no of two way switch with cables 1.5 sqmm size in PVC conduit
All as per item No 9 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm complete all as specified and directed.
S & F sheet metal enclosure with socket plug top and MCBs single pole and neutral with a two pin and earth plug and socket complete with single pole MCB of 240V and 20 Amps complete all as specified and directed.
S & F 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 32 A "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and incl connections, testing and commissioning complete all as specified and directed.
M & L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 4 Sqmm cable and one run of 4.0 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
M & L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 25 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 6 Sqmm cable and one run of 6.0 Sqmm cable and one run of 25mm dia PVC Conduit shall be measured and paid as one unit.
S & F sheet metal enclosures DB SPN, 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43DB's lk-09suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . Note (MCBs shall be measured and paid separately)
Supply & fixing LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders,including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders,including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed.
S & F MCB SP, 5 to 32 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
S & F MCB SPN, 32 to 40 Amps, 240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
Supply and fixing of MCB TPN, 32 Amps, 415 Volt,10 KA 'C' curve complete all as specified and directed.
Supply and fixing exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed.
Supply and fixing modular blanking plate on existing modular plate & switch complete all as specified and directed.
BLANK
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 25 x 4 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 25 x 4 mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed.
BLANK
Total amount of Sch 'A' Part IV (Earth work and site clearance) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part V (Path & Hardstinding) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part VI (BLANK)
Total amount of Sch 'A' Part VII 'A' (Sewage Disposal) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VII-B (Sewage Disposal)
M & L for Construction of septic tank 50 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2 in foundation, 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
M&L for soakage well with size 3.6 m dia x 3.0 m effective depth including excavation in hard / dense soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4.
Supply and lay pipe ductile Iron, spigot and socket including specials, Class"k-9", 100 mm Dia complete all as specified and directed.
Supply, installation, testing of 1 HP pumps duty (flow and head) 50 lpm x 25m with chrome steel impeller and cutter non clog to pass 40mm size particles including supply, installation with guide rail and lifting chain, cable, earthing, testing complete with 2 year maintenance complete all as specified and directed.
Total amount of Sch 'A' Part VIII A (Area Drainage) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VIII B (Area Drainage)
Supply, installation, testing of Pumping sets, centrifugal , electric driven, supply and install complete up to 5 HP inclusive of starter and PCC foundation complete all as specified and directed.
Total amount of Sch 'A' Part IX (Chain link Fencing) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part X 'A' (External Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART X-B (External Water Supply)
Supply and Laying Pipes galvanized, “Medium grade” pipe of 80 mm dia ,including all fittings ( flanges of thickness min 15 mm, 9 holes for each end of pipe) in trenches / walls / ceilings or laying in floors complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium grade” pipe of 50 mm dia ,including all fittings ( flanges of thickness min 15 mm, 9 holes for each end of pipe) in trenches / walls / ceilings or laying in floors complete all as specified and directed.
Supply and lay MS seamless pipes of thickness 8.08 mm of 100 mm dia heavy grade including all fittings (including flanges of thickness minimum 15mm, 9 holes for each end of pipe) as in trenches or in floors or fixed to walls complete all as specified and directed.
Supply and fix cast iron non return sluice valve conforming to IS 4038, 100 mm dia complete all as specified and directed.omplete all as specified and directed.
Supply and fix cast iron valves, sluice, flanged of class 1.0 PN 100 mm dia complete all as specified and directed.
Supply and fix cast iron valves, sluice, flanged of class 1.0 PN 80 mm dia complete all as specified and directed.
S & F cast iron air valves with double air outlets, confirming to IS 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 100mm dia complete all as specified and directed. Make Kirloskar / Leader / Zoloto / BIR
S & F cast steel ball valves flanged (forged) confirming to IS 9338 50 mm dia complete all as specified and directed. Make Kirloskar / Leader / Zoloto
S & F cast steel ball valves SCR (forged) confirming to IS 9338 40 mm dia complete all as specified and directed. Make Kirloskar / Leader / Zoloto
S & F cast steel ball valves SCR (forged) confirming to IS 9338 20 mm dia complete all as specified and directed. Make Kirloskar / Leader / Zoloto
Supply, install, test and commissioning altoch dosing system (Model ADS-1) without decrin dosing pump consisting 40 litres to 100 litres HDPE or FRP tank with level gauge alongwith agitator with shaft and blade in plastic moulded tank. Lid will have port hole for pouring of altoch and water and necessary decrin dosing pump on the wall at water supply installation complete all as specified and directed. Make DECLIBAC / Miltan Roy / Ramco
Supply, install, test and commissioning decrin dosing pump Model 96 NGQ51 high pressure single head gear motor adjustable dosing pump with accessories and suitable electrical connections of following specifications adjustable high pressure 0 to 100 PSI power 230V 50 Hz RPM-44 output : 2 US GPD to 40 US GsPD at water supply installations coplete all as specified and directed. Make DECLIBAC / Miltan Roy / Ramco
Supply, install, test and commissioning of pumping sets, centrifugal, electric driven of capacity 5 HP (3.7KW) , three phase, 415 volts, 30 m head, discharge 269 LPM, Pipe size (suction and delivery) 100 mm x 100 mm, IP 55, maximum ambient temperature 40 degree centigrade, pump shaft-stainless steel, impeller-stainless steel including PCC foundation of suitable size as recommended by manufacturer complete all as specified and directed. Make Kirloskar / Crompton / Jyoti
Material and Labour for construction of Valve pit chamber of size 900 x 900 x 900 mm using PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation 20cm thick, 23 cm stone wall in C.M (1:4) 15 mm thick rendering all around the stone work in CM (1:6), 75 mm thick PCC (1:2:4) type B-1 coping with 20mm graded stone aggregate including necessary form work for grouted including 3.15 mm thick MS top sheet cover with locking arrangement, MS frame made out of 40x40x6 mm angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishing coat including demolition of existing valve chamber and clearing the debris complete all as specified and and directed.
Material and Labour for construction of Valve pit chamber of size 600 x 600 x 600 mm using PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation 20cm thick, 23 cm stone wall in C.M (1:4) 15 mm thick rendering all around the stone work in CM (1:6), 75 mm thick PCC (1:2:4) type B-1 coping with 20mm graded stone aggregate including necessary form work for grouted including 3.15 mm thick MS top sheet cover with locking arrangement, MS frame made out of 40x40x6 mm angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishing coat including demolition of existing valve chamber and clearing the debris complete all as specified and and directed.
Total amount of Sch 'A' Part XI 'A' (External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XI-B (External Electric Supply)
Supply and lay in trenches or passing through pipe / fixed to wall / pole and duct cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 10 Sqmm 3.5 core complete all as specified and directed. Make Havells / Polycab / Gloster / Finolex
Supply and fixing steel tubular pole 9 m long type 410 SP-31 ISI marked final taper plug, bolts, nuts, screws including painting of pole with two coat of aluminium paint over a coat of red oxide primer including 30 cm alternate steps of black and yellow paint up to height of 1.5m from top of PCC coping complete with base plate of MS sheet 30 cm x 30 cm x 6 mm thick welded at the bittom of pole complete all as specified and directed. Make National Tubing Co Kanpur / Bharat Conduit / Jindal
Supply and fixing of pole box size 450 x 300 x 200 mm fabricated out of 2mm thick MS sheet having 4 Nos Aluminium bus bar of suitable size with 1 No MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with Nuts, bolts, and washers complete all as specified and directed. Make HPL / C&S / Gaurav
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : (i) The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed. (ii) 8.00 No quantity is for Sch 'A' Part-XVIII-Lightining Protection and 9.00 No quantity is for Sch 'A' Part-XVII-Laundry Plant and 6.00 No quantity is for Sch 'A' Part-XI-External Electric Supply and 04.00 No quantity of Sch 'A' Part-XII-DG Set
M & L for Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified or indicated including testing on completion. Note : (i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode. The earth pit and pipe for watering shall be provided in slanting manner. The unit rate include for GI pipees, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item complete all as specified and directed.
Supply, installation, commissioning and testing of feeder pillar board Kisok type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proof and compartmentalized Main L.T Panel (CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 640 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.) Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators. All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded red,yellow,blue & black. Power & Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Plafform for the feeder pillar board with PCC 1:2:4 type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minium 100mm all around the feeder pillar board with following :- Note:- Bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron. Contd.....
(a) Aluminium bus bar capacity 100 Amps for Phase-R-Y-B- 03 Nos & 80 Amps for neutral -1 No (b) MCCB FP 25 KA 63 Amps- 1 Nos(I/C) Make- Legrand/L&T/ABB (c) MCCB TP 16 KA 32Amps - 02 NosO/G Make- Legrand/L&T/ABB (d) MCB SP 10 KA 20 Amps - 01 Nos O/G Make- Legrand/L&T/ABB (e) Direct on line star delta starter for 5 HP motor (3.7KW)-02 Nos (e) complete control panel wiring with copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder
SCHEDULE 'A' PART XII (DG Set)
Supply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 200 KVA, 3 phase 0.8 power factor, 50 Hz,developing 200 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at MALARI and confirming to condition under ISO 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- Make : Kirloskar / Ashok Leyland/ Ruston/Cummins Contd....
(A) Alternator :- Synchronous alternator rated at 200 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions. (b) IP: 23 protections with class ‘H’ insulation. · (c) Permanent lubricating bearing. · (d) Permissible overload of 10% for one hour in 12 hours of operation. Contd....
(B) Diesel Engine: - Adquate capacity of Diesel engine liquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts. iii) Cooling Liquid pump : - Centrifugal type belt driven. iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential type Contd....
v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hoses vi) Lub oil System :- Lubricating oil filter,Lubricating oil pump vii) Air Intake System :- Air intake Manifold,Air cleaner dry type viii) Governer : Electronic type ix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC. x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 01 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. Contd....
xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display. xii) Safety Controls : - Engine low lube oil pressure, high coolant temperature and over speeding of engine. xiii) Coupling arrngement : - Flexible coupling xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames. xv) Base Frame : - Base frame is fabricated either in ISMC or in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete set i.e. along with canopy, engine and alternator. xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. xvii) Battery Charger shall be provided as per manufacturer guidelines. xviii) 1 No battery of 12 V in charged condition with its leads. Contd....
C) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. (i) Manufactured by OEM suitable for 200 KVA DG Set. (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure. (iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge. (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. Contd....
(c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level. vi) The acoustic should be composite in construction and fully assembled integral unit. vii) The DG Set should be provided with external Emergency stop push button. viii) The enclosure should be suitably internally illuminated by LED Lamp fittings. ix) The noise level should be < 75 dB at 1m under free field conditions. x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade. Contd....
D) Control Panel :- Control panel shall be fabricated from 16/14 SWG sheet and powder coated after seven tank treatment process: (i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc. (ii) Instrument fuses and control wiring. (iii) Indication lamps set for running and load on. (iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. Contd....
E) AMF Panel :- Automatic Mains Failure (AMF) Panel made of CRCA sheet 2 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. Contd....
SCHEDULE 'A' PART XIII (Hand Driers and Soap Dispensers)
Supply & fix automatic hand drier machine suitable for single phase supply 230 Volts with ABS plastic body complete all as specified and directed.
Supply and fix automatic soap dispenser complete all as specified and directed.
SCHEDULE 'A' PART XIV (Hot Water Supply)
Supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 Ltrs , Minimum 3 Star rating of BEE with all accessories such as safety valve , thermostate , NRV , connection pipe etc . complete all as specified and directed . Make : Bajaj/Havells/ Venus
SCHEDULE 'A' PART XV (OT Light and UPS System)
Supply, installation,testing and commissioning of shadowless operation theatre light fitting including CVT (230 V/12V, suitable for 1 KVA with emergency lighting unit (for both domes for emergency power backup during power failure), wiring and control panel comprising of Infrared filter and steady illumination, main dome should have light intensity of 1,60,000 lux and satellite dome should have intensity of 1,20,000 lux The OT light shall have detachable and sterilizable handle for focussing lights, Lamp head should have unbreakable outer glass, one dome with 80-85 LED bulb in the other dome 50-55 LED bulb and the colour temperatue should be in the range of 4200 K +/- 200 K four steps of intensity control to be provided on CVT. It shall have emergency power unit and battery backup for 30 min, suitable for 1 KVA, having dome of suitable dia, fully counter balanced movable of ceiling trolly having a minimum longitudinal travel of 1500 mm and axial rotation of 360 degree complete all as specified and directed. Make : Dr Med / Dentis Lewis / Phillips
Supply, installation, testing and commissioning of online UPS of 60 KVA with isolation transformer and static bypass switch, Automatic transfer switch alongwith required sealed maintenance free batteries and batteries stand and backup of 60 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete all as specified and directed. I/P Voltage 360 V - 480 V Nominal frequency - 50 Hz Frequency range for online operation 45-50 Hz I/P current <5% O/P voltage 415 V Make : Microtec/ Leiberts/ Volina
M & L sub main wiring with 4 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including PVC conduit of suitable size medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 1x10.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Four runs of 10 Sqmm cable and one run of 10.0 Sqmm cable and one run of PVC Conduit shall be measured and paid as one unit.
SCHEDULE 'A' PART XVI (Patient Call Bell System)
Supply, fixing and installation of Central display unit and control unit (20) modules with data process and control unit upto 4 digit numeric display for a bed/ toilet complete all as specified and directed. Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/ GADDIEL)
S&F bed side calling unit (Wired) with attached patient hand set with LED indication complete all as specified and directed . (Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/ GADDIEL)
S&F Toilet emergency calling unit with attached pull cord (Wired) complete all as specified and directed. (Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/GADDIEL)
S&F Cat 6 cable for connection from central display unit to bed side calling point complete all as specified and direccted . (Make : D LINK/ FINOLEX/PLAZA).
S&F (heavy duty) 20mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed.
S&F (heavy duty) 25mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed.
Total amount of Sch 'A' Part XVII 'A' (Laundry Plant) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XVII B (Laundry Plant)
M & L Cast Steel Ball Valves SCR (Forged) for GI Tube of 20 mm dia with iron whel head screwed both ends class II suitable for iron pipe complete all as specified and directed.
M & L Cast Steel Ball Valves SCR (Forged) for GI Tube of 40 mm dia with iron whel head screwed both ends class II suitable for iron pipe complete all as specified and directed.
M & L Cast Steel Ball Valves flanged for GI Tube of 50 mm dia with iron whel head screwed both ends class II suitable for iron pipe complete all as specified and directed.
Supplying, installating, commissioning and testing Electrically operated of commercial washing machine, automatic steam heated front loading type heavy duty Washing machine with in built hydro extractor of Cap 25 Kg (per charge) front loading, tiltable, electrically heated,stainless steel body controlled through Programmable logic control (PLC) with low spin extract having , auto reverse, auto timed, auto temperature control, auto water level control, separate, electric motors for wash and extract of suitable matching capacity with suitable RPM, fitted with electric solenoid water and steam valves, non clog motorized drain valves full electric protection against single phasing complete with control penal, complete all as specified and as directed. Make :FABTECH, STEFAB , Net Steel
Supplying, installating, commissioning and testing of Elecrically operated Hydro extractor top loading type stainless steel outer drum and inner basket , self balancing . direct drive with DC injection brake . Automatic features like auto times , auto stoped complete with electric pannel and motor of capacitty 15 Kgs , basket size 550X300 mm , 1000 rpm , drain of diameter 65mm overall diamensions 800x1030x1020 complete all as specified and directed. .Make :FABTECH, STEFAB , Net Steel
Supplying, installating, commissioning and testing of Electrically operated commercial fully automatic drying tumbler of Cap 25 Kg (per charge) front loading, electrically heated,stainless steel body, auto timed, auto stop, auto reverse, with fully die pressed door inner basket stainless steel outer drum double wall insulated with glass wool, electric motors of suitable matching capacity with suitable RPM, full electric protection against single phasing complete with control penal, complete all as specified and as directed. Make :FABTECH, STEFAB , Net Steel
Supplying, installating, commissioning and testing of Electrically operated Industrial washer Extractor sluicing machine of capapcity 15 Kg front loading having effortless unlaoding and extraction heated,stainless steel body controlled through Programmable logic control (PLC) with low spin extract having , auto reverse, auto timed, auto temperature control, auto water level control, separate, electric motors for wash and extract of suitable matching capacity with suitable RPM, fitted with electric solenoid water and steam valves, non clog motorized drain valves full electric protection against single phasing complete with control penal, complete all as specified and as directed. Make : SuperShine ,FABCARE, STEFAB, Lucky Engineering Works, Washex Laundry Systems-Cissel Electrolux wascater Bharti Electrical Appliances
Supplying, installating, commissioning and testing of Industrial washer Dry cleaning machine open pocket with buil in low spin extractor having built in continous filtration system stainless steel inner cylinder with ss laoding unloading door fitted with solid sotrage tank automatic times of capacity 12-17 Kgs , motor drive .5 HP , 36 RPM , extractor motor 2 HP base tank capacity 250 Ltrs , filter tank capacity 250 Ltrs , Electrically operated ,over all diamensions 1020x1090x1800 mm compelte all as specified and directed. Make :FABTECH, STEFAB , Net Steel
Supply , installation , commisioning and testing of flat wrok drying ironer suitable to operate on AC electric supply 3 phase 415 Volt specially designed in return feed type single roller made out of stainless steel of SG 304 air suspended polished ironing chest machined fabricated with pneumatic cassing & lowering adjustable pressure & uniform ironing pressure across the entire rolls perfectly fabricated rolls. steel wool and spring padding rust free with heavy duty thick 100% cloth cover feed and collection tables , roller size 500x3000mm. complete all as specified and directed. Make :FABTECH, STEFAB , Net Steel
S & F for Wet linen trolley of size 650 x 550 x 700 mm fitted with 04 Nos swiving type ball bearing wheels complete all as specified and directed.
Supply and installing dry linen trolley of size 650 x 550 x 700 mm fitted with 4 Nos swivelling type wall bearing wheels complete all as specified and directed.
Total amount of Sch 'A' Part XVIII (Lightining Protection) (For details see Sch 'A' in PDF folder)
Note : Tenderers may note that amount of credit Rs 4,455.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
AMIT ASSOCIATES
KHANDELWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid