RequiredOEM Authorization Certificate Bid to RA enabled No Storage Server ( 2 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Specification Form Factor Rack Rack Size (RU) 1 * Processor Make Intel Intel Maximum Number of sockets available on chipset 2 1 - 16 1/6 Maximum Number of sockets populated with processor 1 1 - 16 Number of cores per Processor 12 12
Required14
Required16
Required18
Required20
Required22
Required24
Required26
Required28
Required32 Or higher Processor Configuration Intel Xeon Silver 4116 ( 2.10GHz/12-core/16.5M B/85W) Intel Xeon Silver 4110 ( 2.10GHz/8-core/11MB/8 5W)
RequiredIntel Xeon Silver 4116 (2.10GHz/12-core 16.5MB/85W) Chipset compatible with CPU - * Expansion Slots Gen 3 (PCIe x1) 0 * Expansion Slots Gen 3 (PCIe x4) 0 * Expansion Slots Gen 3 (PCIe x8) 1 * Expansion Slots Gen 3 (PCIe x16) 1 * Type of RAM DDR4 DDR4 RAM Size (GB) 32 32.0 - 16000.0 Or higher RAM upgradable upto (GB) 768 768.0 - 24000.0 Or higher DIMM Slots (No.) 12 * Type of Hard Disk Drive SSD SSD Total number of slots available for SSD drive 8 * Number of Slots populated with SSD Drive 4 * Capacity offered per SSD Drive (GB) 240 * Total number of slots available for SAS drive 8 * Number of Slots populated with SAS Drive 0 * Capacity offered per SAS Drive 0 * SAS drive Speed (Hot plug or better) (RPM) 15K * Total number of slots 8 * 2/6 available for NL SAS drive Number of Slots populated with NL SAS Drive 0 * Capacity offered per NL SAS Drive 0 * NL SAS drive speed (hot plug or better) (RPM) 15K * Total number of slots available for SATA drive 8 * Number of Slots populated with SATA Drive 0 * Capacity offered per SATA Drive 0 * SATA drive speed (hot plug or better) (RPM) 10K * Total Storage Capacity offered 96000 96.0 - 300.0 Or higher RAID Controller Cache (GB) 2 * RAID Level 5 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard Yes * Mouse Yes * Bays (minimum 2 internal or more hot plug) 28 * USB Ports (version 2.0/3.0) 3 * Certifications
RequiredCompliance support by Windows
RequiredRed Hat or Novell Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G * No of Network Ports - * Networking:dual LAN (10/100/1000) network Yes * 3/6 card FC HBA Dual port card Available * FC HBA Dual port card Speed 16 * Power Management Screen blanking
Requiredhard disk & system idle mode in power on
Requiredset up password
Requiredpower supply surge protected * Redundant Power Supply Yes * Redundant Fan Yes * Server Main Supply 230 V +/-10%
Required50 Hz * Declare SPEC int_rate_base 2006 & specfp_rate_2006 or latest for 1
Required2
Required4
Required8 prcessor as applicable - * Maximum power consumption of the system (Watt) 1000 * Server scalability to be achived within the box & without adding nodes Yes * BIS Registration under CRS of Meity Yes * BIS Registration number & its Validity - * Other Certifications Available - * RoHS Compliance Yes * Availability of Type test reports from Central Govt/NABL/ILAC accreditated lab covering verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp - * 4/6 Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
RequiredAfter completion of the above environmental tests sequence
Requiredwith a recovery period of 1 to 2 hrs
Requiredthe server shall be functional Name & address of Lab - * Test Report No & date - * On Site OEM Warranty (years) 3 3
Required5 Or higher * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.