| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.5 LAdmitted-Finance | -36.12% | ₹11.5 L | L1 | Admitted-Finance |
| 2 | L2₹13.3 LAdmitted-Finance | -26.27% | ₹13.3 L | L2 | Admitted-Finance |
| 3 | L3₹13.9 LAdmitted-Finance | -22.84% | ₹13.9 L | L3 | Admitted-Finance |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Feb 2026, 6:00 pmClosed
Executive Engineer PWD(RandB)nagrota Jammu
Executive Engineer PWD(RandB)nagrota Jammu
Construction of Secondary Biology Room in Higher Secondary School Jindrah (Under PAB 2025-26 (Samagra Shiksha)
2026_PWDJK_301296_4
short enit 72 of 2025-26 dated 21-01-2026
Open Tender
Civil Works
120 days
Executive Engineer PWD(RandB)nagrota Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD(RandB)nagrota Jammu
₹36,000
Yes
26 Feb 2026
23 Jan 2026
4 Feb 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed All kinds of Soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering. shuttering, finishing and reinforcement-All work upto plinth level 1.1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- all works upto plinth level 1:3:6(1 cement 3 coarse sand 6 graded stone agg. 20 mm nominal size) crushed
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in foundation and plinth cement mortor 1:6 (1 cement 6 coarse sand and extra for brick work in super structure above plinth level up floor 5 level (by manual means)
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) & Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundation , footings , basis of columns etc. for mass concrete.
Suspended floors, roofs , landings , balconies and access platform.
Lintels, beams ,plinth beams ,girders,bressumers and centilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Edges of Slabs and Break in floors and walls under 20 cm wide
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb
Providing and Finxing M.S Grills of required pattern in frames of windows etc. with M.S Flats, square or round bars etc including primary coat with approved steel primer all complete. Fixed to steel windows by welding.
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
12mm Cement plaster of mix 1 : 6 ( 1 cement : 6 fine sand)
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class deodar wood : 35 mm thick
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood : 35 mm thick
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood : 35 mm thick
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 asper IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 250x16mm Sliding Door bolts.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 asper IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 asper IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10mm
Providing and fixing aluminium door handles ISI marked anodised (anodic coating not less than grade AC 10 asper IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete 125mm
Providing and fixing aluminium door handles ISI marked anodised (anodic coating not less than grade AC 10 asper IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100mm
Providing and fixing aluminium hanging floor door stopper lSI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :Twin rubber stopper
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
Wiring for light point/ fan point/exhaust fan point/ call bell point wit sq.mm FRLS PVC insulated copper conductor single core cable in su recessed medium class PVC conduit, with modular switch, modular suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC in copper conductor single core cable etc. complete job as per direction engineer-in-charge
Engage of Painter for writing Name of School and Making Logo Etc.
Making Black Board.
Carriage of material by M.T including loading unloading and stacking at site complete
Sand for an av. Lead of 20.00 Kms
Stone aggregate below 40 mm lead up to 20 kms.
Bricks lead up to 20 kms.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_977646.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid