SE 17th (E/M) Circle, PWD, Lucknow
Office of the SE 17th (E/M) Circle, PWD, Lucknow
Janpad Ayodhya sthith circuit house parisar me lagi kharab street lighto ko badlane/repair ka karya
2026_CEEMP_1120023_1
438/2CBW(Ayo Zone)-17E/M/2025-26 Date 18-02-2025
Open Tender
Electrical Works
Percentage
90 days
Ayodhya
Please refer Tender documents.
3 documents required · 3 mandatory
₹766
EE Electrical/Mechanical Division PWD Ayodhya
₹67,000
EE Electrical/Mechanical Division PWD Ayodhya
13 Mar 2026
25 Feb 2026
9 Mar 2026
25 Feb 2026
9 Mar 2026
25 Feb 2026
26 Feb 2026
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120W 8.14.16
Supply and fixing of decorative 40W to 45W LED post top indirect light luminare having pressure die cast Al Body and uv stablized pc clear /frosted glass cover ,with driver set confirming to IP 66 & IK 08 protection,potted driver(not circuitory) complete in all respect . 4800-5400 system lumens high power LED lenses ,120 l/w, PF >095 ,THD <10%,CRI>70, over votage protection >300V and auto restart feature,4KV internal Surge Protection with 5 year warrenty. Cat AAA 23.21
Making Connection of each street light fitting by 2.5 sq mm 3 core flexible copper from pole busbar box to street light fitting. Qout.
Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 20.1.9
Supply and Making end termination with brass compression gland and aluminium lugs for 4x16sqmm (28mm) size of PVC insulated and PVC sheathed/XLPE AL conductor cable of 1.1 KV grade as required. 11.1.33
S/F of 5A to 32A rating 240/415V,10kA, "C" curve Double pole and neutral MCB in existing MCB DB complete with connections, testing and commissioning etc as required.2.10.2
S/F of 5A to 32A rating 240/415V,10kA, "C" curve Single pole and neutral MCB in existing MCB DB complete with connections, testing and commissioning etc as required. 2.10.1
Terminal Block 5Way Analysis
S&F surface/flush mounting 6 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. 2.3.1
Providing and fixing 16A three pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc as required. Analysis
Providing and fixing 25A three pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc as required. Analysis
Power Contactor 18A 3P AC Control. Analysis
Power Contactor 25A 3P AC Control. Analysis
GST @ 18% Extra
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
T1T438T25022026.pdf
Tender Documents • 3.79 MB
BOQ_2083254.xls
BOQ • 0.74 MB
Corrigendum25022026.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .