REPAIRS/REPLACEMENT OF LT UG CABLE, JOINTING WORKS AND OTHER MISC WORKS OF E/M INSTALLATION AT CAD PULGAON
2026_MES_798378_1
8426
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE PULGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE PULGAON
₹48,000
Yes
12 Nov 2026
12 Nov 2026
5 Dec 2026
12 Nov 2026
3 Dec 2026
26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches complete all as specified and as directed by EIC. | 360 | Rm | - | - |
| 2 | Excavation in trenches by mechanical/Mannual means not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed by EIC.. | 77.76 | Cum | - | - |
| 3 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil. complete all as specified and as directed EIC. | 69.98 | Cum | - | - |
| 4 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed EIC. | 7.78 | Cum | - | - |
| 5 | Supply and fixing of 90 mm dia Double Wall Corrugated High Density Polyethylene (HDPE) pipe, conforming to IS 14930 (Part-2):2001, complete as required.The pipe shall be laid in trenches/floors or fixed along walls/poles for protection of electrical cables, including providing and fixing of necessary fittings such as bends, couplers, sockets, end caps and other accessories.The work includes cutting, jointing, proper alignment and installation, ensuring smooth passage and mechanical protection of cables, the HDPE pipe shall be double wall (outer corrugated and inner smooth), heavy duty, suitable for underground cable protection, and shall have adequate ring stiffness and impact resistance for road crossing and buried applications. All joints shall be properly sealed to prevent ingress of water and dust.complete in all respects as specified and as directed by the Engineer-in-Charge.. | 288 | Rm | - | - |
| 6 | Supply, laying and testing LT XLPE insulated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with 95 sq. mm, 3.5-core, aluminium-conductor, 1.1 kV, XLPE-insulated, PVC-sheathed, armoured cable heavy duty in trenches/along pole or wall of following sizes complete all as specified and as directed by EIC. Note:- 1. Excavation and earth work, pipes, clamps, and cable joint shall be measured and paid separetely under respective items :- | 400 | Rm | - | - |
| 7 | Supply & laying in repair 80mm bore galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & as directed by EIC. . | 36 | Rm | - | - |
| 8 | Road cutting for laying of underground cable under roads/railway crossings, pavements and hard standings, by manual means, complete as required.The work includes excavation, providing protection to cable using G.I. pipe of required diameter, laying of cable, and making good the surface/structure to match with the adjoining area after completion of work, complete in all respects as specified and as directed by the Engineer-in-Charge.Note: G.I. pipe and PCC work shall be measured and paid separately under respective items. | 18 | Rm | - | - |
| 9 | Dismantling and taking out the existing unserviceable (damaged/broken) Panel of any type and any size, from the Location and removal from site complete all as specified and directed by EIC. | 6 | Each | - | - |
| 10 | Supply, installation, testing and commissioning of a floor-mounted, totally enclosed, dead-front, compartmentalized outdoor LT Distribution Panel with IP56 protection, conforming to IS/IEC 61439-1 & 2 and IS/IEC 60529. The panel shall be fabricated from minimum 3 mm CRCA sheet steel for the outer enclosure and doors and 2 mm for internal partitions, with suitable barriers to prevent accidental contact with live parts.The panel shall be approved from CPRI and NABL-accredited laboratory, along with routine verification certificates. Form 3b internal separation shall be provided wherever applicable and compatible with the offered construction. The complete assembly shall be suitable for continuous outdoor operation and comply with the approved specifications and directions of the Engineer-in-Charge.
(i) Enclosure and Construction The outdoor panel shall be mounted on a heavy-duty base frame with adequate cable termination space (minimum 750 mm from finished ground level). PCC foundation and grouting shall be included in the quoted rate. The enclosure shall have a sloped rain canopy, filtered ventilation with insect-proof mesh, anti-condensation heater with thermostat and protective MCB, double-door shutters with heavy-duty locks, and weather-resistant EPDM/neoprene gaskets. The complete enclosure shall maintain IP56 protection. The panel shall have RAL 7032 Siemens Grey textured powder coating after suitable seven-tank pretreatment, with all external hardware and accessories corrosion-resistant for outdoor installation. (ii) Earthing The panel shall be provided with a continuous copper earth busbar of adequate cross-section, sufficient earth terminals for all outgoing feeders, and two independent external earthing terminals. All doors, removable covers and metallic non-current-carrying parts shall be effectively bonded to the main earth busbar using flexible tinned copper braids or copper links with crimped lugs. (iii) Cable Entry and Termination The panel shall have removable bottom gland plates and complete cable termination accessories, including double-compression nickel-plated brass glands, suitable aluminium/bimetallic lugs, shrouds and earthing accessories for incoming and outgoing XLPE armoured aluminium cables. Adequate cable space, bending radius and support clamps shall be provided for safe termination, inspection and maintenance. (iv) Internal Wiring Internal control and auxiliary wiring shall be carried out with FRLS copper conductors, adequately rated for the respective circuits, complete with ferrules at both ends, identification tags and suitable terminal blocks.Control wiring shall be separately routed from power wiring wherever required. CT circuits shall be wired through suitable shorting/test terminal blocks.At least 20% spare terminals shall be (v) Protection and Coordination All MCCBs shall provide suitable overload and short-circuit protection and shall be properly coordinated with downstream protective devices. Adjustable protection settings shall be set as per the approved load schedule, and protection coordination/discrimination details shall be submitted for approval wherever applicable. (Vi) (A) INCOMING / MAIN SUPPLY (i) The panel shall be provided with electrolytic-grade aluminium TPN busbars rated minimum 600 A, suitable for 415 V, 50 Hz operation, with a minimum short-circuit withstand capacity of 25 kA for 1 second. The neutral busbar shall be 100% rated. Busbars shall have suitable DMC/epoxy supports at intervals not exceeding 500 mm, bolted joints with anti-oxidation compound, and colour-coded heat-shrink insulation. The complete assembly shall be design verified for temperature rise and short-circuit withstand as per IS/IEC 61439-1 & 2. (ii) Incomer MCCB 01 No. MCCB, 4 Pole, 400A, 415V AC, 50Hz, minimum 36 kA short-circuit breaking capacity, with suitable adjustable overload and short-circuit protection, Ics = 100% of Icu, complete with required accessories.The incomer MCCB shall be provided with suitable external rotary operating handle with extension shaft, door-interlocking arrangement and padlocking facility in OFF position, enabling ON/OFF/TRIP operation from outside with the panel door closed.Make: Schneider Electric (iii) On-Load Changeover Switch 01 No. 4 Pole, 250A, 415V AC, 50Hz on-load changeover switch, .Make: Schneider Electric (iv) Surge Protection Device 01 No. Type-2 SPD, 3P+N, suitable for 415V AC, 50Hz system, with minimum Imax = 40 kA per pole, suitable nominal discharge current, thermal disconnection/backup protection, visual status indication and complete with all necessary accessories.SPD connecting leads shall be kept as short as practicable and suitably routed.Make: Schneider Acti9 iPRD40r (iv) Smart Indicating Lamps 01 Set of three phase indicating lamps, LED type, 240V AC, 50Hz, R-Y-B, complete with suitable protection and accessories. Make: Shakti / BCH / Siemens / L&T (v) Digital Multifunction Meter 01 Set Digital Multifunction Meter for measurement/indication of:Phase-to-phase/phase-to-neutral voltage, Current,Power factor,Active energy (kWh),Frequency,Suitable additional electrical parameters as available Complete with suitable CTs, selector/test arrangement, wiring and all accessories. Make: Schneider Electric – PowerLogic PM5000 series (VII) (B) OUTGOING FEEDERS (i) Outgoing MCCB -01 No. MCCB, 4 Pole, 250A, 415V AC, 50Hz, minimum 25 kA, with suitable thermal-magnetic/electronic overload and short-circuit protection, complete with accessories. Make: Schneider Electric (ii) Outgoing MCCBs -04 Nos. MCCB, 4 Pole, 100A, 415V AC, 50Hz, minimum 25 kA, with suitable overload and short-circuit protection, complete with accessories. Make: Schneider Electric Name Plates and Safety The panel shall be provided with durable identification labels for all incomers, outgoing feeders, MCCBs, changeover switch, meters, indication lamps, busbars and control devices. Two danger notice plates in signal red colour, with danger symbol and voltage indication in Hindi and English, shall be fixed on the front and rear doors.A permanent nameplate shall indicate the manufacturer's name, panel identification, rated voltage and current, frequency, short-circuit withstand rating, IP rating, form of separation, year of manufacture and serial number.
Design Verification, Testing and Documentation
1. The complete panel assembly shall comply with IS/IEC 61439-1 and IS/IEC 61439-2.
2. Before supply, the contractor shall submit GA drawings, wiring schematics, panel layout, BOM, applicable design verification reports, short-circuit and temperature-rise verification, IP56 certificate, earthing verification, and datasheets/certificates for MCCBs, SPD, meters and CTs for approval.
3. Routine verification at the manufacturer's works shall be carried out as per applicable standards, including wiring, functional operation, dielectric properties, protective circuit continuity and mechanical operation. 4. After installation, the contractor shall conduct site testing and commissioning, including insulation resistance, earthing continuity, phase sequence, MSEDCL/DG changeover and interlocking operation, metering and protective device checks.
5. All defects shall be rectified without extra cost to the department, and satisfactory operation shall be demonstrated to the Engineer-in-Charge.
6. The contractor shall submit test reports, commissioning report, as-built drawings, OEM manuals, warranty certificates and approved component datasheets. 7. All materials and accessories shall be supplied, installed, tested and commissioned complete in all respects as specified and directed by the Engineer-in-Charge. Location: Officer Mess, CAD Pulgaon, or as directed by the Engineer-in-Charge. | 1 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tender8426.pdf
Tender Documents • 0.72 MB
BOQ_895624.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .