Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.8 L+₹42,609 (2.60%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance Not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Bid is rejected due to non responsive |
| Sl No | Description | Qty | Unit | DEO Traders L2 | Avinash Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Maintenance and servicing of central AC Plant 21 TR/Package type AC Plant 22.5 TR in a month including repair of minor spare parts and repair works, tighting of nuts Bolts, repairing unserviceable parts and accessories, servicing of pump etc , Cleaning of dust from condensor unit with the help of blower and washing with water through pressure pump ,servicing of motor, oiling, greasing well cleaning with petrol /CRC-226, Checking of leakage etc complete all as specified and directed with proper maint of register and taking sign of JE & AGE E/M .etc complete all as specified and directed. | 11 | Per month | 6,000 ₹66,000 | 5,400 ₹59,400 Lowest |
| 2.00 | Disconnecting the electric connection from starter / motor and control panel including taking out of damaged electric cable tray of any size from the existing position and strip opening, kept in safe custudy, repair the same by welding work re-fixing the same with grouting of angle iron or making PCC block of suitable size of same gauge & reassembling the same and re-fixing back in its original position complete all as specified and directed. | 10 | Each Job | 5,000 ₹50,000 | 4,700 ₹47,000 Lowest |
| 3.00 | M&L for charging refrigerant R407C in the system of Air cooled scrolled type water chiller machines including checking and rectification of leakages complete all as specified and directed. | 210 | Kg | 2,000 ₹4,20,000 | 1,650 ₹3,46,500 Lowest |
| 4.00 | Taking out defective microprocessor control board from the AC Plant unit 21 / 22.5 TR and repair it with complete rewiring of AC panel including connector wire MCB etc connecetd items as per site required by authorised service enginner or from manufacture service centre and fixing the same with connection complete with satisfactory working all as required and directed by Engineer in charge. | 4 | Each Job | 15,000 ₹60,000 | 13,500 ₹54,000 Lowest |
| 5.00 | S&F in replacementof liquid line filter (Drier)of suitable size and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | 1,100 ₹4,400 | 800 ₹3,200 Lowest |
| 6.00 | S&F in replacementof pressure release valve (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | 1,100 ₹4,400 | 800 ₹3,200 Lowest |
| 7.00 | S&F in replacement of air release valve fitted in water chiller line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | 1,100 ₹4,400 | 900 ₹3,600 Lowest |
| 8.00 | S&F in replacement of H.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | 1,100 ₹4,400 | 900 ₹3,600 Lowest |
| 9.00 | S&F in replacement of L.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | 1,100 ₹4,400 | 950 ₹3,800 Lowest |
| 10.00 | S&F in replacement of 3 pole ,415 volt 50 Hz, 40 Amp contactor,of coil voltage 230 volt complete all as specified and directed.Make - Siemence or as approved by Engr-in -charge | 4 | Each | 2,700 ₹10,800 | 2,400 ₹9,600 Lowest |
Tender Value
₹16.4 L
EMD Value
₹32,800
Closing Date
24 Mar 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Offg GE I R AND D KANPUR
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/MAINT OF AC PLANTS AT TECH AREA AND CERTAIN REPAIRS OF INSTALLATIONS UNDER GE(I) R AND D KANPUR
2026_MES_754932_1
8481/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KANPUR
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹32,800
Yes
12 Nov 2026
2 Mar 2026
1 Apr 2026
2 Mar 2026
24 Mar 2026
17 Mar 2026
2 Mar 2026 - 16 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance and servicing of central AC Plant 21 TR/Package type AC Plant 22.5 TR in a month including repair of minor spare parts and repair works, tighting of nuts Bolts, repairing unserviceable parts and accessories, servicing of pump etc , Cleaning of dust from condensor unit with the help of blower and washing with water through pressure pump ,servicing of motor, oiling, greasing well cleaning with petrol /CRC-226, Checking of leakage etc complete all as specified and directed with proper maint of register and taking sign of JE & AGE E/M .etc complete all as specified and directed. | 11 | Per month | - | - |
| 2 | Disconnecting the electric connection from starter / motor and control panel including taking out of damaged electric cable tray of any size from the existing position and strip opening, kept in safe custudy, repair the same by welding work re-fixing the same with grouting of angle iron or making PCC block of suitable size of same gauge & reassembling the same and re-fixing back in its original position complete all as specified and directed. | 10 | Each Job | - | - |
| 3 | M&L for charging refrigerant R407C in the system of Air cooled scrolled type water chiller machines including checking and rectification of leakages complete all as specified and directed. | 210 | Kg | - | - |
| 4 | Taking out defective microprocessor control board from the AC Plant unit 21 / 22.5 TR and repair it with complete rewiring of AC panel including connector wire MCB etc connecetd items as per site required by authorised service enginner or from manufacture service centre and fixing the same with connection complete with satisfactory working all as required and directed by Engineer in charge. | 4 | Each Job | - | - |
| 5 | S&F in replacementof liquid line filter (Drier)of suitable size and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | - | - |
| 6 | S&F in replacementof pressure release valve (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | - | - |
| 7 | S&F in replacement of air release valve fitted in water chiller line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | - | - |
| 8 | S&F in replacement of H.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | - | - |
| 9 | S&F in replacement of L.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed. | 4 | Each | - | - |
| 10 | S&F in replacement of 3 pole ,415 volt 50 Hz, 40 Amp contactor,of coil voltage 230 volt complete all as specified and directed.Make - Siemence or as approved by Engr-in -charge | 4 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender8481.pdf
Tender Documents • 0.73 MB
BOQ_845549.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .