Loading…
Loading…
Tender Value
₹15.6 Cr
EMD Value
₹31.2 L
Closing Date
25 May 2026, 3:00 pmClosed
No
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
SIGNAL
16 conditions · 5 needing a document upload
The tenderer must have minimum average annual contractual turnoverofV/N or 'V' whichever is less; where V= Advertised value of the tenderincrores of Rupees N=Number of years prescribed for completion ofwork forwhich bids have been invited.The average annual contractualturnovershall be calculated as an average of "totalcontractualpayments" in theprevious three financial years, as per theaudited balance sheet. However,in case balance sheet of the previousyear is yet to be prepared/ audited,the audited balance sheet of thefourth previous year shall be consideredfor calculating average annualcontractual turnover. The tenderers shallsubmit requisite informationasper Annexure-VIB, along with copies ofAudited Balance Sheets dulycertified by the Chartered Accountant/Certificate from CharteredAccountant duly supported by Audited BalanceSheet.
Audited Balance sheet as per above description along with informationasper Annexure-VIB (of GCC) to be enclosed.
Bid Capacity :- Firm has to submit details in annexure F1 of Appendix ,duly certified by charted accountant as per GCC ANNEXURE - VI for evaluation of bid capacity.
(a) The tenderer must have successfully completed orsubstantiallycompleted any of the following during last 07 (seven) years,ending lastday of month previous to the one in which tender is invited:Threesimilar works costing not less than the amount equal to30%ofadvertised value of the tender, or Two similar works costing notlessthan the amountequal to 40% of advertised value of the tender, orOnesimilar work costing not less than the amount equal to 60%ofadvertised value of the tender. (b) (i) In case of composite works(e.g.works involving more than one distinct component, such asCivilEngineering works, S&T works, Electrical works, OHE works etc. andinthe case of major bridges substructure, superstructure etc.),tenderermust have successfully completed any of the following duringlast 07(seven) years, ending last day of month previous to the one inwhichtender is invited: Three similar works costing not less than theamountequal to 30% of advertised value of each component of tender, orTwosimilar works costing not less than the amount equal to 40%ofadvertised value of each component of tender, or One similarworkcosting not less than the amount equal to 60%of advertised valueofeach component of tender. Note: Separate completed works ofminimumrequired values shall also be considered for fulfillment oftechnicaleligibility criteria for different components.
The similar nature of the work is defined as: "Any signaling work involving outdoor work and/or addition and/or alteration in existing indoor signaling system .OR Any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving indoor and/or outdoor.Similar work to include indoor if the tendered work involves addition and/or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work.ORAny such work involving activities as given in the name of the tendered work."
21 conditions · 4 needing a document upload
As per the tender document attached.
As per the tender document attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Supply installation testing and commissioning of Signalling material in connection with following work:- 1)- Tajpur additional loop line in connection with Simhastha 2028. 2)- Naikheri yard remodeling with additional loop and stabling line in connection of Simhastha 2028. 3)-Rajendra Nagar provision of stabling line in connection with Simhastha 2028. 4)-Pingleshwar Emergency crossover in connection with Simhastha 2028. 5)- Barlai additional loop line in connection with Simhastha 2028. 6)- Vikram nagar Extension of machine Siding and dead ends of Line Number 1 to stable full length trains in connection of Simhastha 2028.
SnT_RTM_26_08_Signal
SnT_RTM_26_08_Signal
Open
Works - General
12 Months
Ratlam, Madhya Pradesh
₹0
₹31.2 L
25 May 2026
2 May 2026
11 May 2026
773 items across 33 schedules · ₹14,20,71,454.01 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Main Signal Post Tubular 140 mm Dia, 4.6 Mtr Length as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). | Numbers | 8.00 | 8,199.23 | 65,593.84 |
| 2 | Supply Color Light Signal Accessories. ( Signal Post Tubular 140 mm Dia, 5.6Mtr Length as per IRS: S-6/81 ) | Numbers | 8.00 | 10,895.41 | 87,163.28 |
| 3 | Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186. | Numbers | 20.00 | 615.59 | 12,311.8 |
| 4 | Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R. | Numbers | 3.00 | 4,439.28 | 13,317.84 |
| 5 | Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | Numbers | 8.00 | 28,577.72 | 2,28,621.76 |
| 6 | Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | Numbers | 8.00 | 29,823.91 | 2,38,591.28 |
| 7 | Junction route indicator unit 1way as per Drg. No. RDSO SA 23401 suitable for LED Signal Lighting Unit & as IRS: S-66/84 amndt-1or latest. (Supply of LED Unit is not covered in this item). | Numbers | 2.00 | 21,050.52 | 42,101.04 |
| 8 | Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. | Numbers | 1.00 | 20,990.76 | 20,990.76 |
| 9 | Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv.) Alt1 suitable to LED Signal Lighting Unit. | Numbers | 2.00 | 2,669.43 | 5,338.86 |
| 10 | Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | Numbers | 3.00 | 4,530.07 | 13,590.21 |
| 11 | Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | Numbers | 1.00 | 3,359.74 | 3,359.74 |
| 12 | Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | Numbers | 30.00 | 3,523.27 | 1,05,698.1 |
| 13 | Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | Numbers | 60.00 | 2,129.53 | 1,27,771.8 |
| 14 | Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged). | Numbers | 140.00 | 2,213.81 | 3,09,933.4 |
| 15 | Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | Numbers | 30.00 | 978.46 | 29,353.8 |
| 16 | Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | Numbers | 150.00 | 1,120.65 | 1,68,097.5 |
| 17 | GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | Kg | 1000.00 | 68.17 | 68,170 |
| 18 | Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | Numbers | 8000.00 | 6.04 | 48,320 |
| 19 | Miniature, Plug-in Type, DC Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F- 8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23. | Numbers | 70.00 | 4,284.48 | 2,99,913.6 |
| 20 | Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F- 8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | Numbers | 30.00 | 5,576.04 | 1,67,281.2 |
| 21 | Relay, AC Immune, Plug-in-type, style "QNA1K" ACI DC Neutral line, 24V DC 1000 Ohms 6F.6B contacts, front contacts metal to carbon and back contacts metal to carbon. Complete with plug board, retaining clip and connectors confirming to IRS: S34, IRS: S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA (PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY. | Numbers | 10.00 | 5,525.31 | 55,253.1 |
| 22 | Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | Numbers | 20.00 | 5,613.1 | 1,12,262 |
| 23 | Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23. | Numbers | 30.00 | 7,390.44 | 2,21,713.2 |
| 24 | Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60- 78. | Numbers | 30.00 | 5,421.4 | 1,62,642 |
| 25 | Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | Numbers | 30.00 | 7,393.68 | 2,21,810.4 |
| 26 | Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | Numbers | 30.00 | 4,878.9 | 1,46,367 |
| 27 | Miniature, Plug in type, M to C, AC immunized, DC biased Track Relay, 2F-2B contacts, style QBAT-9 ohms. Code ABEJX Spec:- RDSO/SPN/84 Ver. 2 : IRS -S@45"44@IRS-S-23, IRS-S@45<45N46@ | Numbers | 2.00 | 5,393.68 | 10,787.36 |
| 28 | Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | Numbers | 20.00 | 9,743.97 | 1,94,879.4 |
| 29 | Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | Numbers | 4.00 | 24,008.12 | 96,032.48 |
| 30 | Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | Numbers | 100.00 | 18.6 | 1,860 |
| 31 | Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | Numbers | 100.00 | 50.99 | 5,099 |
| 32 | Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS: S-80/92. | Numbers | 100.00 | 34.44 | 3,444 |
| 33 | Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92. | Numbers | 350.00 | 129.41 | 45,293.5 |
| 34 | D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge. | Numbers | 20.00 | 31.93 | 638.6 |
| 35 | D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS: S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. | Numbers | 20.00 | 34.86 | 697.2 |
| 36 | Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | Numbers | 450.00 | 57.21 | 25,744.5 |
| 37 | Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non- Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | Each Module | 1.00 | 51,953.78 | 51,953.78 |
| 38 | Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non- Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | Each Module | 2.00 | 29,743.63 | 59,487.26 |
| 39 | Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | Numbers | 500.00 | 58.53 | 29,265 |
| 40 | Supply of End plate 2.5mm/0.091 in thick as per site requirement. | Numbers | 225.00 | 11.07 | 2,490.75 |
| 41 | Supply of End Stopper 10mm/0.0394 in width as per site requirement. | Numbers | 313.00 | 10.86 | 3,399.18 |
| 42 | Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | Numbers | 17.00 | 113.88 | 1,935.96 |
| 43 | Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments. | Numbers | 5.00 | 3,354.08 | 16,770.4 |
| 44 | Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | Numbers | 20.00 | 10,403.08 | 2,08,061.6 |
| 45 | Supply of Fiber/ SMC/FRP/RCC Earth Chamber. | Numbers | 20.00 | 649 | 12,980 |
| 46 | ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | Numbers | 1500.00 | 75 | 1,12,500 |
| 47 | Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two no.s of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | Numbers | 20.00 | 15,611.07 | 3,12,221.4 |
| 48 | Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two no.s E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | Numbers | 15.00 | 9,893.99 | 1,48,409.85 |
| 49 | IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | Numbers | 35.00 | 5,388.67 | 1,88,603.45 |
| 50 | Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | Kilometre | 2.00 | 5,548.54 | 11,097.08 |
| 51 | Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | Kilometre | 0.50 | 1,36,063.55 | 68,031.78 |
| 52 | Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | Numbers | 50.00 | 1,912.2 | 95,610 |
| 53 | Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | Running Metre | 100.00 | 1,170.28 | 1,17,028 |
| Schedule total | ₹47,99,889.04 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022ACSNo_11.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
ACS-2toGCC-2022.pdf
ATTACHMENT
GCCApril2022ACSNo_3_1.pdf
ATTACHMENT
GCCApril2022ACSNo_4.pdf
ATTACHMENT
GCCApril2022ACSNo_5.pdf
ATTACHMENT
GCCApril2022ACSNo_6.pdf
ATTACHMENT
GCCApril2022ACSNo_8.pdf
ATTACHMENT
GCCApril2022ACSNo_9.pdf
ATTACHMENT
GCCApril2022ACSNo_10.pdf
ATTACHMENT
Tender_documentSidingwork2.pdf
ATTACHMENT
Appendixsidingwork1.pdf
ATTACHMENT
NaiKheri-ESP.pdf
ATTACHMENT
RajendraNagar-ESP.pdf
ATTACHMENT
Barlai-ESP.pdf
ATTACHMENT
VikramNagar-ESP_compressed.pdf
ATTACHMENT
TJPSIP.pdf
ATTACHMENT
Pingleshwar-ESP.pdf
ATTACHMENT
revisedTANearthingHQletter040725_1.pdf TAN earthing
ATTACHMENT
GCCApril2022ACSNo_7.pdf
ATTACHMENT
revisedTANearthingHQletter040725_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .