| 1 | L1₹1.7 LAccepted-AOC GOPKOLIA SAKTIGARH PURBA BARDHAMAN PIN 713149 | PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713149 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.7 L+₹993 (0.58%)Rejected-AOC 40 B PREM CHAND BARAL STREET KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.7 L+₹1,584 (0.93%)Rejected-Finance NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
8 Jul 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
Katwa Electrical Sub-Division office P.W.Dte
SITC of Split Type RAC and allied Electrical Works at SDOs anti-chamber and The Chamber of DM DC Kalna Sub-Divisional office in the district of Purba Bardhaman.
2024_WBPWD_700353_1
WBPWD/AE-KESD/NIQ-09/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
KALNA
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,500
10 Dec 2024
26 Jun 2024
10 Jul 2024
26 Jun 2024
8 Jul 2024
27 Jun 2024
Amount
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. (E-11/D-1) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes(F-5/9) 4 Sqmm
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(E-19/17)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.(E-17/5a )
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections(E-17/5b)
Supply, Installation, Testing & Commissioning of Inverter type split AC machine having Cooling Capacity range (6.6 KW - 7.0 KW), with variable speed compatible rotary compressor, refrigerant gas R 32 / R 410A, (ISEER range 3.8 to 4.39 or higher), Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, both indoor and outdoor PCB should be in metal enclosure and connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ O General/ Johnson Controls (Hitachi))
Inatallation, Testing and Commissioning charges of the both the indoor and outdoor unit by MS angle fixing on wall or ceiling by suitable fixing arrangement with MS Angle Iron bracket(2 coat RO & 1 coat powder coated paint) nut bolt washer or fastner etc.
Supply & installation of Easty to bend, Corrossion free Annealed extra-added Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall. a) Liquid Line(3/8"OD with 0.6mm thick) (make: Godrej/Carrier Total Line/ MI Copper)
b) Suction line(5/8"OD with 0.7mm thick) (make: Godrej/Carrier Total Line/ MI Copper)
S & F nitrile rubber tube Insulation on suction/liquid line copper pipe of concealed split AC. a) Liquid Line
b) Suction line
Supply and laying of 4 core 2.5 sq.mm 1.1 KV grade unsheathed FR Cu cable with gas line as per direction of EIC for Indoor to Outdoor Communication for Split type AC m/c.(Make:- Polycab/ Havells/ KEI/RR Kabel)
Supply and Laying of 3core 4 sq.mm 1.1 KV grade unsheathed "FR" Cu cable with gas line as per direction of EIC for starter to Outdoor for Split type AC m/c.(Make:- Polycab/ Havells/ KEI/RR Kabel)
Supply & Laying 20mm dia heavy type PVC braided hose pipe for water drainage of RAC machine.(Brand approved by EIC).
Rates to be quoted will be inclusive of all the taxes incl. GST. No other additional charges will be applicable in addition to the quoted rates.
BHATTACHARJEE AIR CONDITIONING
SREE GURU ENGINEERING
technical_1526760.pdf
PDF • 0.16 MB
techsummary_1526760.pdf
PDF • 0.16 MB
finance_1526760.pdf
PDF • 0.15 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1526760.pdf
PDF • 0.20 MB
AOC.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .