Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-Finance VILL PO KUMARHATTI DISTT SOLAN HP 173229 | KUMARHATTI | SOLAN | HIMACHAL PRADESH | 173229 | ₹30.5 L | L1 | Accepted-Finance Lowest bidder |
| 2 | L2₹31.0 LAccepted-Finance | ₹31.0 L | L2 | Accepted-Finance Other than lowest bidder |
| 3 | L3₹32.9 LAccepted-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹32.9 L | L3 | Accepted-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | R B TRADERS L3 | Vishal Builder L1 | RR Builders L2 |
|---|---|---|---|---|---|---|
| .01Schedule 'A' Section - I | ||||||
| 1.00 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern as in roof coverings complete all as specified and as directed. | 612.5 | Square Metre | 10 ₹6,125 | 20 ₹12,250 | 20 ₹12,250 |
| 2.00 | Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick conforming to IS-15961 of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws on wooden trusses in any position or slope upto any height complete all as specified and directed.
Note- The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. Contractor shall submit a Purchase voucher and manufacturer test certificate to Engineer-in-Charge before claiming payment. | 485 | Square Metre | 850 ₹4.1 L | 796 ₹3.9 L | 760 ₹3.7 L |
| 3.00 | Supply and fixing plain mild steel sheeting 0.60 mm thick, in rain water gutters, drip and straight flashings (length and girth as fixed ), ridges, hips, and similar work etc fixed as welded or soldered joints, reveting are provided etc complete all as specified and directed.
Note : i) Rates are included for providing nozzles, stop ends, drop ends made of mild steel sheeting 0.60mm thick with necessary fixing arrangement/ jointing with rubber sealant for PVC downwater pipes.
ii)The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. Contractor shall submit a Purchase voucher and manufacturer test certificate to Engineer-in-Charge before claiming payment. | 50 | Square Metre | 850 ₹42,500 | 825 ₹41,250 | 770 ₹38,500 |
| 4.00 | Supply and fixing plain, black, 1mm thick mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) , welded or soldered joints complete all as specified and as directed . | 50 | Square Metre | 950 ₹47,500 | 790 ₹39,500 | 950 ₹47,500 |
| 5.00 | Material and labour for mild steel works for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, hook and pintle hinges: clamps; hold fasts; wall ties; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. | 70 | Kilogram | 120 ₹8,400 | 110 ₹7,700 | 105 ₹7,350 |
| 6.00 | Material and Labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) as in fixing of hold fasts, copings, bed plates,kerbs or mud stops, lintels upto 1.50m span, plinth courses , seismic and other bands and the like, finished the surface fair and even, including necessary form work complete all as specified and directed.
Note- If reinforced concrete, reinforcement shall be measured and paid for separately. | 1.6 | Cubic Metre | 6,500 ₹10,400 | 6,200 ₹9,920 | 6,500 ₹10,400 |
| 7.00 | Dismantling boarding any description, fixed in any position with nails or screws, etc. including fillets complete all as specified and as directed. | 712 | Square Metre | 10 ₹7,120 | 20 ₹14,240 | 25 ₹17,800 |
| 8.00 | Supply and fixing in repairs 40mm thick 2nd class hardwood boarding as in floors, planed one side, with butt joints and fixed with nails, etc. complete all as specified and as directed. | 10 | Square Metre | 1,400 ₹14,000 | 1,500 ₹15,000 | 2,000 ₹20,000 |
| 9.00 | Material and labour for 9 mm thick plywood, 5 No of ply, grade BWP, type BB fixed with screws over timber frame work or over existing wooden planks flooring including preparation of existing wooden planks flooring surface plane, smooth and free from any overhead nails or screws etc complete all as specified and directed. | 290 | Square Metre | 750 ₹2.2 L | 650 ₹1.9 L | 625 ₹1.8 L |
Tender Value
₹40.5 L
EMD Value
₹81,060
Closing Date
23 Mar 2026, 6:00 pmClosed
Lt Col Jeethu Vijayan, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
SPECIAL REPAIR TO BLDG NO OTM BLDG NO TL-02, OTM 13A (OR MESS) AD OTM 02 AT DAGSHAI UNDER GE KASAULI
2026_MES_755124_1
GEK-76/2025-26
Open Tender
Civil Works
180 days
DAGSHAI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹81,060
Yes
1 Apr 2026
3 Mar 2026
25 Mar 2026
3 Mar 2026
23 Mar 2026
18 Mar 2026
4 Mar 2026 - 7 Mar 2026
Schedule 'A' Section - I
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern as in roof coverings complete all as specified and as directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick conforming to IS-15961 of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws on wooden trusses in any position or slope upto any height complete all as specified and directed. Note- The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. Contractor shall submit a Purchase voucher and manufacturer test certificate to Engineer-in-Charge before claiming payment.
Supply and fixing plain mild steel sheeting 0.60 mm thick, in rain water gutters, drip and straight flashings (length and girth as fixed ), ridges, hips, and similar work etc fixed as welded or soldered joints, reveting are provided etc complete all as specified and directed. Note : i) Rates are included for providing nozzles, stop ends, drop ends made of mild steel sheeting 0.60mm thick with necessary fixing arrangement/ jointing with rubber sealant for PVC downwater pipes. ii)The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. Contractor shall submit a Purchase voucher and manufacturer test certificate to Engineer-in-Charge before claiming payment.
Supply and fixing plain, black, 1mm thick mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) , welded or soldered joints complete all as specified and as directed .
Material and labour for mild steel works for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, hook and pintle hinges: clamps; hold fasts; wall ties; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Material and Labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) as in fixing of hold fasts, copings, bed plates,kerbs or mud stops, lintels upto 1.50m span, plinth courses , seismic and other bands and the like, finished the surface fair and even, including necessary form work complete all as specified and directed. Note- If reinforced concrete, reinforcement shall be measured and paid for separately.
Dismantling boarding any description, fixed in any position with nails or screws, etc. including fillets complete all as specified and as directed.
Supply and fixing in repairs 40mm thick 2nd class hardwood boarding as in floors, planed one side, with butt joints and fixed with nails, etc. complete all as specified and as directed.
Material and labour for 9 mm thick plywood, 5 No of ply, grade BWP, type BB fixed with screws over timber frame work or over existing wooden planks flooring including preparation of existing wooden planks flooring surface plane, smooth and free from any overhead nails or screws etc complete all as specified and directed.
Material and labour for PVC tiles / sheets 2.50 mm thick laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based /synthetic adhesive or as per manufacturer's instructions etc for fixing over wooden planks flooring complete all as specified and as directed. Note- Contractor shall submit a Purchase voucher and manufacturer test certificate to Engineer-in-Charge before claiming payment.
Supply and fixing for mild steel section framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, window guard bars, and fixed independently in wooden frames including fixing mild steel screws, supports for shelves, sinks, etc and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fixing in repair hard drawn steel wire fabric, weight n.exc 4 kg/Sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement etc complete all as specified and as directed.
Dismantling timber scantling 40 sq.cm and over in section in any position in framed or unframed work etc complete all as specified and as directed.
Supply and fixing second class hard wood over 40 sqcm in section as in roof trusses, members, scantling, or in other position,etc. timber framed and clean sawn, complete all as specified and as directed.
Material and labour for 6 mm thick (5ply) plywood, plywood, grade BWR, type BB fixed with screws to timber frame work or over existing wooden planks flooring including preparation of existing wooden planks flooring surface plane, smooth and free from any overhead nails or screws etc complete all as specified and directed.
Material and labour for Second class hardwood (Hollack) plain fillets, square, rectangular or triangular in section of area exceeding 13 Sq. cm and not exceeding 25 Sq. cm, clean sawn, fixed straight or curved, secured with nails or brads, etc. complete all as specified and as directed.
Material and labour for 2nd class hard wood plain fillets sectional area exceeding 06 Sq. cm and not exceeding 13 Sq.cm, square, rectangular or triangular in section, clean sawn, secured with nails or brads etc complete all as specified and as directed.
Taking down cement plaster of any description, thickness, in any position and height from brick or stone wall or concrete surface, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Material and labour 20mm thick rendering in cement mortar (1:6) on other than fair faces of stone masonary, brick or concrete surface and finished the surface even and smooth without using extra cement complete all as specified.
Material and labour 20mm thick rendering in cement mortar (1:4) on other than fair faces of stone masonary, brick or concrete surface and finished the surface even and smooth without using extra cement mixed with @ 200 ml WPC (liquid type) per bag of cement or as per manufacturer’s instructions complete all as specified and directed. Note:-WPC (liquid type) shall be measured and paid separately as supply only.
Material and labour for 10mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified.
Material and Labour for 15mm thick rendering on surface of any description of brick work, concrete surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement mixed with @ 200 ml WPC (liquid type) per bag of cement or as per manufacturer’s instructions complete all as specified and directed. Note:-WPC (liquid type) shall be measured and paid separately as supply only.
Taking down loose plaster from ceiling of slab, edges and soffit of chajjas and the like, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, cleaning of old reinforcement and applying neat cement slurry@ 3Kg per sqm and 30mm thick (in two layers , each layer 15mm thick) plaster in cement mortar 1:3 mixed with @ 200 ml WPC (liquid type) per bag of cement not exc 3 sqm each patch including removal of rubbish/demolished material to a distance exceeding 250mtr and not exc 500mtr , including provsion of scaffolding up to 10m height required for repairing work and applying three coats of white lime wash complete all as specified and as directed Note:-WPC (liquid type) shall be measured and paid separately as supply only.
Supply only liquid water proofing compound of approved make all as specified and directed.
Material and labour providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed.
Taking down shutters of any description exceeding 1.00 Sq.m but not exceeding 2.00 Sq.m each, from chowkhat including iron mongries and removing from site complete all as specified.
Taking down wooden chowkats or frames area not exceeding 1.50 Square metre (w/o taking off shutters from frames) including iron mongries and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish , complete all as specified and as directed.
Taking down wooden chowkats or frames area exceeding 1.50 square metre and not exceeding 4.00 Square metre (w/o taking off shutters from frames) including iron mongries and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish , complete all as specified and as directed.
Material and labour 2nd class hardwood as in plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed
Supply and fixing factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed.
Supply and fixing 35 mm thick, 2nd class hard wood, partly or fully glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc divided into squares with plain, chamfered or rounded, mitred beads, rebated sash bars any numbers for securing glass, etc or partly with panels of 9mm BWP commercial ply etc with size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a) complete all as specified and as directed.
Demolition of brick or stone masonary built in cement mortar including all quoins arches pillars upto 10 mtr height as in roof chimney, walls , manholes, chambers and similar work etc including precast concrete block complete all as specified and as directed.
Material and labour brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing aluminium power coating of approved colour (Thickness or powder coating not less than 50 micron) frame for doors, windows, ventilators, partitions incl necessary joining cleats, rubber packing, snap beading, glazing clips for fixing glass etc with one or more rebates or double/ triple track channels for sliding shutter windows including joining cleat and steel screw for fixing frame to walls/jambs etc. complete all as specified and directed.
Supply and fixing powder coated aluminium anodised window(Three track sliding window, 02 shutters with glass and 01 shutter with wiremesh) made out hollow aluminium as mentioned below. Each shutter shall have 01 No. aluminium handle of 75mm size and 02 Nos self locking device. Window shall be glazed with 4.00mm thick tinted glass fixed with glazing clips, rubber beading and anodized aluminium beading and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or stainless steel wire staple etc complete all as specified and as directed:- Chowkhat bottom section size : 50.3mm X 26.0mm, 1.20mm thick Chowkhat top & sides section size : 50.3mm X 15.0mm, 1.00mm thick Shutter top & bottom rail section size : 101.60mm X 44.45mm, 1.50mm thick Shutter inner lock rail section size : 37.5mm x 15.0mm, 1.50mm thick Shutter side mid rail section size : 37.5mm x 15.0mm, 1.36mm thick Note :- (i) The door/window shall be as per drawings/directions of Engineer-in-charge and drawing may be reffered from GE office. (ii) Minimum thickness of anodization shall be 15 micron. NOTE: (Glass and wire mesh shall be paid seperately)"
Supply and fixing aluminium power coating of approved colour (Thickness or powder coating not less than 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, aluminium snap beading, screws etc. complete all as specified
Material and labour for applying 1 mm thick wall care putty on walls including sanding with sand paper to remove any loose particles, unevenness, wrinkles to achieve a smooth and even surface, etc. complete all as specified and as directed.
Material and labour for applying 2 mm thick wall care putty on walls in two layers of 1mm thick each layer and sanding with sand paper to remove any loose particles, unevenness, wrinkles to achieve a smooth and even surface of any description, etc. complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over a coat of Chalk whitening, etc. complete all as specified and as directed.
Material and labour for preparation of old plastered surfaces of wall by complete removal of existing treatment with mechanical scrapper including washing, rubbing down dust and loose particles and applying two coat of oil bound distemper, complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces and applying two coats of cement base paint complete all as specified and as directed.
Material and labour for two coat of cement base paint over old decorated plastered surface including preparation of surface complete all as specified and directed
Material and labour for complete removal of existing treatment on surfaces of wall by using appropriate technique not exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer when unconnected with other painting or when painted in different tint and make etc complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description not exceeding 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparing new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified.
Material and labour for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.
Supply and fixing mild steel butt hinge of 100mm length, cold rolled, medium weight, ISI marked complete all as specified and directed.
Supply and fixing, aluminium anodised barrel tower bolts of extruded section, 200mm, ISI marked, complete all as specified and directed .
Supply and fixing, aluminium anodised barrel tower bolts of extruded section, 150 mm, ISI marked, complete all as specified and directed .
Supply and fixing, extruded aluminium alloy handles with plates, fabricated type, anodised 150mm size, ISI marked, complete all as specified and directed .
Supply and fixing 300 mm aluminum anodised sliding door bolt, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as specified and directed.
Supply and fixing 200 mm aluminum anodised sliding door bolt, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 12mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as specified and directed.
Supply and fixing in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
Supply and fixing for floor door stopper of aluminium alloy body and tongue , anodised with hard drawn steel spring over all length of cover plate 150mm complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed
Material and labour for Sheet glass 4.8 mm thick ordinary quality for windows, ventilators, doors and partitions of any size fixed with oil putty or with aluminium snap beading etc complete all as specified and as directed.
Supply and fixing 4.80 mm thick obscured or frosted glass, ordinary quality and glazing with oil putty or fixing in aluminium shutters/frames in any shape and size complete all as specified and as directed.
Supply and fixing stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
Dismantling floor, hearth or wall tiling of any description (Ceramic/PCC/Terrazo) and any thickness, including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed..
Material and labour glazed ceramic coloured tiles premium/1st quality in vertical surfaces/skirtings/dados of size 300x600 x7mm/ 450x 300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed.
Material and labour Non Skid coloured ceramic tiles, joint free, premium/1st quality, 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour Non Skid coloured ceramic tiles joint free premium/1st quality of same description as of floor tiles in serial item No 64.00 above but 150mm height as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed.
Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise specially provided complete all as specified and directed.
Supply and fixing 0.63 mm thick galvanised corrugated mild steel sheeting, class-8 with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, ISI marked in roofs, walls, etc. at any height, with grade of zink coating 275, complete all as specified and directed.
Supply and fixing 0.80 mm thick Plain, galvanized mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) at any height, with grade of zink coating 275 complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar etc complete all as specified and as directed.
Material and labour for machine cut kota stone slab 18-22 mm thick (of size not less than (55 cm x 55 cm) laid in glooring and jointed & pointed with grey cement slurry mixed with pigment to match shade of the slab including cutting waste, rubbing and polishing (Granite finish) over and including cement screed bed 20mm thick in cement mortar (1:4) base , complete all as specified.
Material and labour for machine cut kota stone slab 16-18 mm thick laid on verticle surface and jointed & pointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish) but as in skirting over and including 10mm thick plaster in cement mortar (1:3) on brick work or concrete surfaces, complete all as specified.
Material and labour for 18-20 mm thick Granite (of any type) work ( table rubbed and polished) in steps, jambs, window cills, cooking platform, wash hand basin , urinal partition etc and like fixed to wall in verticle position laid over 10 mm thick rendering/screed bed in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite to match the shade of the slab and rounding of edges complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and directed.
Supply and fixing in repair decorative stainless steel of approved quality curtain rod 25mm dia having wall thickness 1.60 mm with and including decorative stainless steel brackets ,stop roller at the end/ finials etc, fixed with stainless steel screws complete all as specified and as directed.
Material and labour for taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by the Engineer-in-Charge
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area) single core FRLS-H, PVC insulated and unsheathed stranded cable 1100 volts grade ISI-694 marked TEC and FIA approved in and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush box , inner and outer plate as required for housing modular switch and socket as per module including FRLS-H,PVC insulated and unsheathed, copper conductor 1:5 Sqmm nominal cross sectional area wire as earth continuity conductor upto common earth and connecting to common earth dolly for one light/fan/bell point controlled by one switch. Note :- Modular Switch, socket and fan regulators to be measured and paid for separately) complete all as specified. PVC Conduit confirming to IS 9537 part I & III. Note :-(All chases will be cut by chase cutter only).
Description same all as per item No. 77.00 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed.
Description same all as per item No. 77.00 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed.
Description same all as per srl item No. 77.00 here-in-before but for one socket outlet 15 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed
Material and labour for sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade, ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material and labour for sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade, ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed.
Supply & fix modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed.
Supply and fixing Ceiling rose surface bakelite 65x50mm three terminals, complete all as specified and as directed.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
Supply and fixing for Bell, electric,Ding Dong AC, 230 volts, single pole fixed in repair complete all as specified and directed.
Supply and fixing in repair surface mounted LED fitting 18W, 220 V, AC, in extruded aluminium with driver, including LED tube light including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in repair surface mounted LED fitting 10W, 220 V, AC, in extruded aluminium with driver, including LED tube light including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing in repairs of 9/10 W LED bulk head luminairies incl LED light with clear prismatic diffuser,driver holder connecting up with three core flexible copper conductor cable of suitable size including all acessories for fixing on wall all as specified and directed.
Supply and fixing in repair LED security light 35 watt LED with lence and water/weather proof powder coated high pressure dia cast housing with IP-66 built - in control driver, aluminium reflector, heat resistant toughened clear glass, connector block, surge protection fixed on ceiling/pole/wall with bracket made up of 0.50m long GI pipe, 25mm dia, medium grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and 1.5 sqmm 3 core flexible wire from ceiling rose to light fitting complete all as specified and directed .
Supply and fixing self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) complete all as specified and as directed.
Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed .
Supply and fixing sheet metal enclosures for distribution board for MCB's Load line TPN, 4 ways,double door, 415 volts, with and including 200 amps rated bus bar, vertical type IP 42, with MCCB as incomer and MCB's as out going and making all type of connections with suitable size of gland for incomer LT cable complete , concealed on the wall surface, making good the disturbed portion with adjoining surfaces to match with existing finish complete all as specified and as directed.
Supply and fixing sheet metal MCB DB, SPN, 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed.
Supply and fixing sheet metal MCB DB, SPN, 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed.
Supply and fixing in repair, MCCB, 4 Pole, 415 volts, 100 Amps, 16 kA rupturing capacity and making connections complete all as specified and as directed.
Supply and fixing in repair MCB, Single Pole and neutral, AC supply, 240 volts, 40 Amps, 'C' series,10 kA rupturing capacity and making connections complete all as specified and as directed.
Supply and fixing in repair MCB, SP, AC, 240 volts 'B' curve capacity of 06 to 32 Amps, 10kA and making connections with suitable thimble complete all as specified and as directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as inhardstanding, finishing cement concrete surface even and smooth with out using extra cement complete laid in alternate bays including demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and directed.
Supply and fixing in repair, single pole enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve complete all as specified and as directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.and including taking down unserviceable and deposit to E/M Store. Note:- Geyser will be fitted with fastners-04 Nos including bolts washers etc and making good disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement exhaust fan AC single phase 230/240 volt of size 300 mm sweep plastic body with louver and connecting with twin twisted copper conductor flexible of size 0.50 sqmm fixing nut bolts necessary for fixing exhaust fan complete all as specified and as directed.
Supply and fixing of exhaust fan, steel body AC single Phase. 230V, of size 380mm sweep, with, blades, frame and louvers shutters, mounting on walls with holding down bolts, nuts, washers and connection of flexible copper conductor cable three core ceiling rose to fan and testing including taking down unserviceable exhaust fan complete all as specified and directed.
Taking down old unserviceable earthing after disconnecting the existing earthing and making good to the existing surface complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete complete all as specified and as directed.
Dismantling and taking down old unserviceable underground cable of any size and description from trenches/pole/duct/LT panel after disconnecting from OH conductors and renove the same from site complete all as specified and as directed.
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in hard/dense soil complete, all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
Supplying & fixing in replacement of double walled corrugated HDPE duct pipe of 50 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittinggs for cable protection complete all as specified and directed.
Supply & laying or fixing or passing through pipe, testing and commissioning of 1100 Volts, grade heavy duty, PVC sheathed armoured cable LT, XLPE cable ,insulated aluminium conductor multi strandard served with an inner sheathing of PVC tape armoured with galvanised steel wire and tape of size 35 Sqmm nominal cross sectional area 3.5 core with suitable glands and lugs complete all as specified and directed.
Supply & laying or fixing or passing through pipe, testing and commissioning of 1100 Volts, grade heavy duty, PVC sheathed armoured cable LT, XLPE cable ,insulated aluminium conductor multi strandard served with an inner sheathing of PVC tape armoured with galvanised steel wire and tape of size 16 Sqmm nominal cross sectional area 2 core with suitable glands and lugs complete all as specified and directed.
Supply & laying or fixing or passing through pipe, testing and commissioning of 1100 Volts, grade heavy duty, PVC sheathed armoured cable LT, XLPE cable ,insulated aluminium conductor multi strandard served with an inner sheathing of PVC tape armoured with galvanised steel wire and tape of size 10 Sqmm nominal cross sectional area 2 core with suitable glands and lugs complete all as specified and directed.
Amount of credit of Rs. 136329.35 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
GEK762526.pdf
Tender Documents • 1.14 MB
BOQ_845769.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid