Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.6 L+₹2.4 L (11.3%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.6 L+₹5.3 L (25.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹30.0 L+₹8.7 L (41.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹31.2 L+₹10.0 L (47.1%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-AOC L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bahratpur-321026
Comprehensive maintenance of LT Panels LT cable earthing and connected work at Kanjoli line Dayal bagh MES IB at Mil Stn Bharatpur
2024_MES_663774_1
8402/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE Bahratpur
₹60,000
Yes
5 Oct 2024
3 Jul 2024
6 Sept 2024
3 Jul 2024
4 Sept 2024
17 Jul 2024
4 Jul 2024 - 16 Jul 2024
Amount
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, exc1.5 Mtr wide but n. exc 3Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed ,
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed ,
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed ,
Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenches complete all as specified and directed, (Note :- Punning thickness shall be measured.)
M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified and directed ,
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT type of 10 sqmm to 25 sqmm any size complete all as specified and directed.
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT type of 35 sqmm to 50 sqmm any size complete all as specified and directed ,
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT type of 70 sqmm to 120 sqmm any size complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete specified & directed by Engg in charge of the following sizes:-
120 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
25 Sqmm 4 core
16 Sqmm 4 core
10 Sqmm 2 core
S&F in repair on existing location including taking out of existing MCCBs of following capacity complete specified & directed by Engg in charge.
MCCB 415 volts thermal magnetic release adjustable type 400 Amps 04 pole 36KA
MCCB 415 volts thermal magnetic release adjustable type 250 Amps 04 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 200 Amps 04 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 160 Amps 03 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 100 Amps 04 pole 25 KA
MCCB 415 volts thermal magnetic release adjustable type 63 Amps 04 pole 25 KA
S & F MCB TPN 63 Amps C curve 415 V, 10 KA complete all as specified and directed.
Taking out old u/s pipe of any size
S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified and directed.
S & F for laying galvanixed steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls or under road crossing of size 80 mm bore complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology and necessary machine for laying under ground pipe up 100mm dia complete all as specified and directed. Note :- GI pipe shall be measured and paid in concern Item
M&L for LT cable fault rectification of following sizes given by using Fault locator machine to detect fault and rectify the same incl T&P & items ie lugs,tape etc complete all as specified and directed.
10 sqmm to 25 sqmm X 3.5/4 core
35 sqmm to 70 sqmm X 3.5/4 core
95 sqmm to 240 sqmm X 3.5 core
M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detaction of fault location complete all as specified and directed. Note: Earth work and returning filling which require in above job will be measured and paid seperataly.
16 Sqmm to 25 Sqmm
35 Sqmm to 70 Sqmm
95 Sqmm to 240 Sqmm
Material and Labour for cleaning of dust particles from inside the LT Panel by air blowers, tightening of loose connections, filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock complete all as specified and directed.
Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 30/32 watt in Aluminium Die casting body / FRP Bpdy ,corrosion resistance,integrated PV panel Automatic dusk to input voltage 12.8V with suitable battery ,Driver efficiency .85%,PV module itself will be used to sense the ambient light to switch ON/OFF the Lamp,inbuilt MPPT charge controller,IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per watt,5700ANSI,cool white(5500K-6500K),CRI.70,moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(120 degree) LED Life 50000 hrs,weight less than 15 kg with GReen/Red indicator swith with suitable battery rating 12.8V-BIS standard of complete all as specified and directed.
M& L for renewal of Earthing complete with galvanised mild steel plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end connected to metallic bodies of HT/LT equipment etc at the other and earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x6 mm flat iron clamps bolts, nuts and washers and including providing watering pipe 20mm bore GI Pipe electrode complete all as specified and shown in elctrical plate No 3 of MES SSR Part-I. the scope of work includes necessary excavation and earth work in any type of soil. removal of soil upto 50 metre PCC pit with precast RCC cover, charcoal/salt funnel, CI frame etc complete all as specified and directed. NOTE:(I) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC(1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars @ 150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Item includes cost of 7.5 metre earth lead strip .Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thinkness of 15 cm on all sides.
M&L for cement concrete 1:3:6 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,fillinf and mass concrete complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified and directed.
S&F in replacement new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts (Surge protection of the light should be 10 KV )with suitable drivers etc fixed to Pole/Wall in any position including taking down complete all as specified and directed.
S & F street light GI bracket of 1.2 mtr long made out of 32 mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 25 x 4mm including nuts bolts & washers with fixing of LED street light complete necessary fixing arrangements on pole complete all as specified and directed.
S & F in replacement 4 sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular from junction box to fitting complete all as specified and directed.
Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 280 x 170 x 105 mm depth with cable entry size of 10-25 sqmm with 4 No. busbar of capacity 63 Amp and MCB SP 6 Amp-1 No.of make sintex each, with flat iron clamps of size 25 x 4 mm, nuts and bolts complete including taking down complete all as specified and directed.
M&L in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
Trimming/prunning and removing of tree branches or any other forein objects from street light illumination of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and directed. Notes: (i) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job.
Supplying, errecting and fixing steel tubular swaged poles with Mild iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
S&F ON LOAD change over switch 415V with & including outdoor type sheet metal enclosures of size 600x450x450 mm with bus bar of size 400 Amp capacity (sheet thickness 3.15 mm ) including necessary angle iron stand grouted in PCC, 4 pole of capacity 200 Amps with in and out cable gland complete complete all as specified and directed.
Supply installed testing and comminsioning outdoor type,Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 40 KVAR (1 KVAr-1 Nos,2 KVAr-1 Nos, 5 KVAr-01 No, 10 KVAr-03 Nos, and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each control and MCCB TPN 125 Amp 16 KA as incomer including control CT & control wiring complete having following assessories including control wiring with HR FRLS copper wirecomplete all as specified and directed. (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry (ii) Capacitor installed in removable assemblies for ease of operation and maintenance (iii) Incoming of APFC panel of MCCB TPN 125 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating (iv) 40 KVAR ((1 KVAr-1 Nos,2 KVAr-1 Nos, 5 KVAr-01 No, 10 KVAr-03 Nos) MCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . (v) High performance microprocessor based 3 phase APFC relay 4 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)
(vii) Induced air system provided with axial flow fan/ centrifugal fan. (Viii) Capacitor duty contactor of suitable size (ix) CT-03 Nos for LT Panel & necessary copper wire 6 sqmm for connection (x) Bottom cable entry system available with front glass for viewing controller and analyzer from front. Note: panel mounted on 45 cm height pcc platform above ground level and 0.35 below ground level
M/S MAMTA CONSTRUCTIONS (BID ID -3071931)
Gaurav & company (BID ID -3069547)
M/s Ranaji Construction Co (BID ID -3079082)
Vijay Electricals (BID ID -3081042)
PD GUPTA AND COMPANY (BID ID -3071505)
Unnati Engineers (BID ID -3078104)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .