Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | ₹7.8 L Quoted ₹7.9 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹9.1 L+₹1.1 L (14.3%)Rejected-Finance | ₹9.1 L+₹1.1 L (14.3%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | Rejected-Technical C O VAUDE VILLE HARDWARE OPP IOC DZUVURU KOHIMA NAGALAND 797 001 | KOHIMA | KOHIMA | NAGALAND | 797001 | - | - | Rejected-Technical NIT Criteria is not fulfill |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
16 Oct 2023, 6:00 pmClosed
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
REPAIRS/MAINTENANCE OF DG SETS OF VARIOUS RATING, SOLAR BATTERY AND LIGHT INCLUDING RO PLANT AND ITS ALLIED WORKS AT CHAKABAMA MILITARY STATION UNDER AGE(I) ZAKHAMA
2023_MES_613985_2
8184/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹17,000
9 Nov 2023
26 Sept 2023
19 Oct 2023
26 Sept 2023
16 Oct 2023
3 Oct 2023
Amount
Material and Labour for ‘B’ check servicing all as per manufacturer instructions, including cost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of make Kirloskar/Cummins and Alternator of capacity 62.5 KVA, installed at Main Receiving Station at Chakabama Military Station, complete testing after repair for its smooth functioning :- (a) Lubricating oil filter Kirlosakar - 01 Nos (b) Fuel filter Kirloskar - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit Note : 1. Quoted rated deems to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2. Engine oil, Coolant for radiator, distilled water, new air filter element and spares parts shall be measured and paid separately under relevant item of this schedule.
Supply only Air filter element inner suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply only Air filter element outer suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply only engine oil Kirloskar Super engine oil grade 20W40 against 'B' check servicing and as per the capacity of engine model and as per manufacturers recommendation complete all as directed.
Supply and fix in repairs, Radiator hose suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Cooler hose suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, water pump suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Thermostate switch suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Screen Filter suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Diesel filter suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Bypass filter suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, V belt suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Dynamo belt suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA.
Supply and fix in repairs, Lube oil cooler suitable for DG set Engine of make Kirlosakar and capacity 62.5 KVA Lube oil cooler
Supply and fix in repairs, Turbo charger DG set Engine of make Kirlosakar and capacity 62.5 KVA.
All as per item No 01 here-in- before but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed at Pump House No 2 and 3 at Chakabama Military Station. (a) Lubricating oil filter Kirlosakar - 02 Nos (b) Fuel filter Kirloskar Part No - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit Note : 1. Quoted rated deems to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2. Engine oil, Coolant for radiator, distilled water, new air filter element and spares parts shall be measured and paid separately under relevant item of this schedule.
Supply only Air filter element inner and oute for 125 KVA DG set.
Supply and fix in repairs, Diesel filter suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs, Fan belt suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs, Automatic voltage regulator suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs, lubricant oil cooler suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs,Engine Safety unit suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs, Thermostate suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Supply and fix in repairs, water pump suitable for DG set Engine of make Kirloskar/ Cummins and capacity 125 KVA.
Taking down unserviceable Solar street Light f 43/60 W LED dismantling, checking replacement of unserviceable parts and components as required and make the solar light fittings operational to give rated illumination including cleaning the solar plate and refixing the same after repair/replacement of spare components complete with repair of battery box as per required welding work complete all as specified and as directed. Note :-(Spare parts/components shall be measured and paid separately under respective item of such 'A'
S & F in repairs, Solar Light fitting LED 43 Watts complete all as specified and as directed.
Supply only lead acid solar battery maintenance free 12 volts 150AH Tubular as per cat part No 6LMS150L of make EXIDE Xpress fully charged complete all as directed.
S&F in repairs, Fully Automatic Star Delta Starter of 4 Pole 3 Phase 415 Volts of capacity 150 HP s.specified and as directed by Engr-in-Charge
S&F in repairs, MCCB with Thermal - magnetic release of 200 Amps , 4 Pole, 415V, 36 kA, 50 Hz Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repairs, MCCB with Thermal - magnetic release of 160 Amps , 4 Pole, 415V, 36 kA, 50 Hz Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
Repairs/maintenance and servicing of RO plant, 250 Liters capacity in under mentioned locations by replacement of unserviceable parts to make it serviceable including cleaning of membrane active, carbon filters sand, silex media property if required with the help of changing chemical (recommended by manufacturers) complete all as specified and as directed. Note: spares parts shall be measured and paid separately under relavant item of this schedule.
Supply only Activated carbon for Reverse Osmosis (RO) plant capacity 250 Liters complete all as specified and directed
Supply only sand Media for Reverse Osmosis (RO) plant capacity 250 Liters complete all as specified and directed
Supply only Silex Media for Reverse Osmosis (RO) plant capacity 250 Liters complete all as specified and directed
Supply only Replacement of membrane, suitable for RO Plant of capacity 250 LPH, low energy/brikish type BW 30-4040.
Supply only 2" x 20" Cartridge large filter 1 micron paper/spun type.
Supply only Antiscalant chemical/Solution for Reverse Osmosis (RO) plant capacity 250 Liters complete all as specified and as directed.
M&L for dismantling high pressure motor of capacity up to 2HP & cutting the unserviceable winding wire, cleaning the stator and rotor and rewinding the same with supper enameled copper winding wire of existing gauge and turn including varnishing, PVC sleeve, cotton tape insulation paper and all other material required for rewinding including lathe work of shaft and replacement of defective bearings two No's (6203/6205 of make NBC/SKF) and refixing back in original position complete all as specified and as directed.
M&L for dismantling of flushing pump of capacity 0.5HP stainless steel body & cutting the unserviceable winding wire, cleaning the stator and rotor and rewinding the same with supper enameled copper winding wire of existing gauge and turn including varnishing, PVC sleeve, cotton tape insulation paper and all other material required for rewinding including lathe work of shaft complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried in ground (Earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level , connected to galvanised iron earth strip 25 mm x 4 mm as earth lead by means of nut, bolts check nut and wahser of galvanised iron or steel etc all as shown in electrical plate No.3 of SSR part I- 2009 connected to earth test point all as specified or indicated including PCC pit in PCC (1:3:6) type C-1 cast iron MS frame, 50 mm thick pre cast RCC (1:1 1/2:3) type nominal mixed cover slab rainforced with 8 mm dia MS deformed bar 15 C/C and suitable for handle cast including necessary exavation earth work in soft/loose soil and disposal of soil to adistance n exc 50 m and charcoal 120Kg, salt 105 kg, funnel with water pipe ,wire mesh, copper logs etc GI protection pipe of size 15 mm bore dia including demolition of old earthing complete including testing all as specified and directed by Engr-in-charge.
das enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .