Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.1 CrAccepted-AOC | ₹5.1 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹6.2 Cr+₹1.1 Cr (22.6%)Rejected-Finance | ₹6.2 Cr+₹1.1 Cr (22.6%) | L-2 | Rejected-Finance Not Validated. Other than L-1 Bidder. |
Tender Value
₹4.1 Cr
EMD Value
₹4.9 L
Closing Date
1 Jun 2022, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF ELECTRICITY AND WATER SUPPLY AT 4 CORPS ADHOC CETC LOKARA UNDER GE (N) TEZPUR
2022_MES_500870_2
98736/TEZ(N)/SZ/E8
Open Tender
Civil Works
Lump-sum
365 days
LOKARA
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
GE (N) TEZPUR
₹4.9 L
Yes
21 Sept 2022
28 Apr 2022
3 Jun 2022
28 Apr 2022
1 Jun 2022
17 May 2022
28 Apr 2022 - 6 May 2022
Amount
BUILDING AND STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDING AND STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,08,35,000.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE & SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE & SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,59,253.47 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 9,340.42 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,13,343.07 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH & CULVERT (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,18,034.19 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 65,465.67 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' PART-VII)
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,71,895.02 inserted by the MES in Schedule ‘A’ Part-VII.
EXTERNAL WATER SUPPLY (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 23,87,936.13 inserted by the MES in Schedule ‘A’ Part-VIII.
EXTERNAL ELECTRIC SUPPLY (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 40,36,414.80 inserted by the MES in Schedule ‘A’ Part-IX.
FENCING AND GATE (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “FENCING AND GATE” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,68,190.88 inserted by the MES in Schedule ‘A’ Part-X.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (TO BE QUOTED BY CONTRACTOR)
Material and labour for drilling trial bore of 250mm dia upto 120 mtrs depth with reverse rotary circulation or direct circulation or combination of both by using power Rig for housing of 300mm nomial bore reduced to 150mm below ground leveling in any kind of soil strata including hard stone boulders etc complete all as specified and directed. NOTE :- (i) In case the result of the bore hole/Strata are found un-satisfactory & the tube well is not likely to yield the specified quantity of water, the site shall be abandoned & the contractor shall be paid for boring part only. (ii) Removel of Mud/Slurry from the site shall be deemed to be included in the unit quoted rate. (iii) The rate quoted is deemed to be include for hire of charges of Rig, T&P, Machinery, fuel charges, labour, consumeables, transportation,drilling and operation duly painted including use and waste of all necessary all appliances and materials in all respects to all entire satisfaction of complete work all as specified and directed. (iv) Depending upon the availability of water bearing strata, if drilling beyond 120 mtr is required the same shall be carried out after obtaining written approval. (v) The rate for rig boring beyond 120 mtr depth will be considered as per quoted rate for this item.
Material and labour for Reaming upto 525mm from ground level including filling of pea gravel of size 3mm to 8mm in surrounding of casing pipe of 300mm dia and vacant space between bore hole and casing pipe complete all as specified and directed. NOTE: Cost of casing pipe will be measured and paid under relevent items.
Material and labour for Reaming upto 525 mm after the depth executed under Item No. 11.02 upto the depth of 120RM including filling of pea gravel of size 3mm to 8mm in surrounding of casing pipe of 150mm dia and vacant space between bore hole and casing pipe complete all as specified and directed. NOTE:- (i) Depending upon the availability of water bearing strata, if drilling beyond 120 mtr is required the same shall be carried out after obtaining written approval . (ii) The rate for reaming beyond 120 mtr depth will be considered as per quoted rate for this item. (iii) Cost of casing pipe will be measured and paid under relevent items.
Supply lowering and fixing/ jointing 150mm bore low carbon galvanised (LCG) strainer 3 mtr/ 6 mtr long min 6mm thickness each conforming to IS 8110:2000 including mild steel socket threaded/ by electric arc welding both sides all as specified and directed with aperture 0.75mm to 1mm as per requirement complete all as specified and as directed.
S&F of MS taper reducer of 300x150 mm with and including socket threaded and by electric arc welding both side complete all as specified and as directed
Supply and fixing well cap made out of 5mm thick MS plate suitable for fixing to 300mm nominal bore ERW heavy duty MS casing pipe of 7mm wall thickness with provision of suitable holes for passing two runs of flat three core, PVC insulated industrial cable 10.00 sqmm for submersible motor, complete all as specified and directed.
Supply and fixing of Bail Plug having 3.00 metre length and suitable for 150 mm bore, 7.00 mm thick casing pipes, complete all as specified and directed.
M&L for electrologging testing of trial bore by authorised govt scientist/agency including submission of test report duly signed complete all as specified and directed.
Testing of raw and treated water from NABL accredited Lab / Govt Lab for testing of Physical, Chemical parameters, Heavy metal (Toxic) parameter, Microbiological test, Pesticide group, Parasitological analysis and Virological analysis as per IS 10500:2012 and submitting the test report complete as specified and directed. NOTE : Water testing of raw water to be done immediately after completion of drilling process of bore well.
Development of tube well with compressed air and after with 25% extra capacity pump by pumpping muddy water complete all as specified and directed.
Yield test for the borewell by continuisly pumping for 16 hours to determine safe pumping yield complete all as specified and directed.
Supply only strata sample box with glass cover 3mm thick having internal dimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisam with hinges, hasp and staple including polishing complete with samples at various depth evenly 2 mtr interval met in boring including strata chart in duplicate all as directed and specified.
S&F mild steel work as in joist channel, angles or tee sections plates fixed independently with or without connecting plates etc out to required length and shape including two coats of synthetic enamel paint over one coat of red-oxide primer all as specified and as directed. (work for lifitng of submersible pump set).
S&F steel/GI rope flexible 10mm dia with GI clamps, nuts, bolts, washer etc for fixing of submersible pump set complete all as specified and as directed
Supply and fix chain pully block of capacity 3 ton and lifting height 6 mtr with extra length of 5mtr of chain complete all as specified and directed.
S & F Water pressure gauge 96mm dia dial type having range 0 to 10 Kg/Sqcm suitable fixed on delivery mains complete all as specified and as directed
(iii) Power in KW/HP of Submersible motor is tentive which shall be calculated according to Pump discharge and head and as recommended by OEM. The head and LPM of pump in any condition shall not be less than 750 LPM at 54 m head. (iv) Submersible pump shall have stainless steel / Brass impeller and sufficient stage to suit the above required head and discharge and pump shall be suitable for lower in bore well. (v) Pump and motor should be of same make. (vi) New submersible pumps have to be lowered in bore well and commissioned by the contractor.
Supply and connecting flat three core, PVC insulated industrial cable for submersible motor, 10 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed.
Supply, installation, testing and commissioning of silent built in within and acoustic enclosure noise level not more than 75dB, diesel engine driven generating set water cooled for standby power supply 415 volts, 03 phase, 4 wire, 50 cycles/ sec, 50 KW AT 0.8 Lagging power factor complete with alternator directly coupled with diesel engine of suitable capacity, mounted on common base frame & complete with self starter 12 volt, fuel tank capacity not less than 12 hours fuel requirement & battery 12 volts of suitable AH lead acid type, battter leads, sound proof canopy etc. with features for authomatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc & PSO 500 genset controller with the fwg under mentioned features all as specified and as directed including foundatin as per OEM design and specification:- (a) 16 character x 2 line aplhanumeric LCD display with LED backlight. (b) Operator interface. (c) Suitable to provide a record of most recent fault conditions & fault history. (d) Complete alternator date viz, voltage ph-hp, ph- neutral, KVA, frequency etc. (e) Complete engine date viz, starting battery voltae, engine temp, engine running hours, engine oil pressure etc. (f) Control including provn of service adjustment & calibration of DG control function.
Supplying & laying synthetic Rubber insulation mat 2.5mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (Superseding IS 5424) suitable for electrical shock safety of size 2m x 1m complete all as specified and directed.
Construction of brick masonary valve pit of size 90cmx90cmx90cm (internal dimension), foundation with 150mm thick PCC 1:4:8 type D2, brick work shall be full brick thick wall in CM (1:4), 15mm thick rendering in cement mortar (1:4) internally, external upto 15 cm from GL complete with MS angle iron frame work angle size 40x40x6mm fixed on top of valve pit by means of hold fast 150mm long embedded in PCC 1:2:4 type B1 of size 230mmx200mmx100mm, 3mm thick MS sheet top cover openable through hinges 02 Nos, handle and locking arrangement, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces and two coats of black bituminous paint over acoat of primer inside complete all as specified and directed.
Construction of brick masonary valve pit of size 60cmx60cmx60cm (internal dimension), foundation with 150mm thick PCC 1:4:8 type D2, brick work shall be full brick thick wall in CM (1:4), 15mm thick rendering in cement mortar (1:4) internally, external upto 15 cm from GL complete with MS angle iron frame work angle size 40x40x6mm fixed on top of valve pit by means of hold fast 150mm long embedded in PCC 1:2:4 type B1 of size 230mmx200mmx100mm, 3mm thick MS sheet top cover openable through hinges 02 Nos, handle and locking arrangement, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces and two coats of black bituminous paint over acoat of primer inside complete all as specified and directed.
S&F MS pipe heavy duty 100 mm bore 3 mtr long both end flanged with suitable nut bolt washer gasket etc complete all as specified and directed.
S&F MS pipe heavy duty 100 mm bore with all fittings complete all as specified and directed.
S&F MS pipe heavy duty 150 mm bore with all fittings complete all as specified and directed.
S&F CI Flanged pipe class B 100 mm (4'') dia complete all as specified and directed.
S&F Non return Valve of size 100 mm (4'') dia complete all as specified and directed.
Supply and lay Ductile iron pipe single socketed including all fittings, class 'K-9',100 mm(4'') complete all as specified and directed. NOTE : DI fittings will be measured under separate item.
Supply and lay Ductile iron pipe single socketed including all fittings, class 'K-9',150 mm(6'') complete all as specified and directed. NOTE : DI fittings will be measured under separate item.
Supply and fixing sluice valve 80mm bore, ISI marked, confirming to IS 14878, with valid CML No, Batch No, Manufacture sl No, Class PN 1.0 with brass spindle, brass checknut, including fiber board gasket, bolts, nuts and washer for fixing the valve in position as specified and directed. NOTE : Contractor shall submit the test certificate of sluice valve.
Supply and fixing sluice valve 100mm bore, ISI marked, confirming to IS 14878, with valid CML No, Batch No, Manufacture sl No, Class PN 1.0 with brass spindle, brass checknut, includingfibre board gasket, bolts, nuts and washer for fixing the valve in position as specified and directed. NOTE : Contractor shall submit the test certificate of sluice valve.
Supply and fixing sluice valve 150mm bore, ISI marked, confirming to IS 14878, with valid CML No, Batch No, Manufacture sl No, Class PN 1.0 with brass spindle, brass checknut, including fibre board gasket, bolts, nuts and washer for fixing the valve in position as specified and directed. NOTE : Contractor shall submit the test certificate of sluice valve.
Supply, installation, testing and commissioning water treatment plant of 10000 Gallon capacity comprising of oxidation chamber, pressure filter cum iron removal plant, air compressor with back wash facility, Alum mixture, dosing pump, tank & agitator, soda ash dosing pump, tank and agitator, pre and post chlorination dosing pump, tank and agitator assy complete including supply, fixing connectingall piping work with heavy duty MS pipe of suitable size for filters and heavy duty CPVC pipe for alum , soda ash and pre & post chlorine dosing plant, with fittings of any shape and size as required at site and as recommended by OEM, inclnon-return valves, check valves,sluice valves (butterfly type), air release valves, Gun metal gate valves, all ISI marked of suitable size and including PCC work foundationfor installation of plants with followings specifications:- (i) Oxidation Chamber :Qty -01 Nos . Oxidation chamber shall be of closed type, vertical pressure vessel made up of MS as per IS 2062, with food grade rubber lining inside, cylindrical top & bottom dish ends, having shield thickness min 6 mm MS + 3 mm rubber lining inside. It shall have design flow rate 46 cum/ hrs, Design pressure -4 Kg /cm2, Max test pressure -6 Kg/ cm2 and having filled with MnO2 media. Item Continued as 11.36
(ii) Air compressor:-Qty 01 Nos Air compressor shall have min air flow rate of 5.0 CFM, Working pressure – 6Kg/cm2, electric motor capacity shall not less than 2 HP or as recommended by OEM single phase, 240V, 50 Hz with complete electrical wiring and starter. Make : Ingersoll Rand or equivalent (iii) Chlorine dozer (Pre chlorination):Qty : 02 Nos (01W +01 Stand by): It shall be of mechanically actuated diaphragm metering pump of flow rate 1 to 10 LPH, Min Pressure rating – 3.5 Kg/cm2 , Dosing motor TEFC, of min 0.25 HP, 230V, AC, 50 Hz including chemical resistant FRP solution tank (min thickness 5 mm) of 200 ltr capacity- 01 No and agitator assy having motor capacity min 0.25HP, 230V, AC, 50 Hz with complete with mechanical arrangement and including dosing pipe, electrical wiring and starter for motors and other accessories as required complete all as specified and directed. (iv) Alum Doser: Qty - 02 Nos (1No working + 1No Standby): It shall have Mechanically actuated diaphragm metering pump having flow rate 3 to 30 LPH, Min Pressure rating – 3.5 Kg/cm2, Dosing motor, TEFC, of min 0.5HP, Single phase, 230V, AC, 50 Hz with chemical resistant FRP solution tank (having min thickness 5mm)- 01 No of 500 Ltr and agitator assy with motor capacity min 0.5 HP, 230V, AC, 50 Hz complete with mechanical arrangement and including dosing pipe, electrical wiring and starter for motors and other accessories as required complete all as specified and directed. Item Continued as 11.37
(v) Soda Ash Doser: Qty :02 Nos (1No working + 1No Standby) : It shall having Mechanically actuated diaphragm metering pump having flow rate 3 to 30 LPH, Min Pressure rating – 3.5 Kg/cm2, Dosing motor, TEFC, 0.5HP, single phase, 230v, AC, 50 HZ with chemical resistant FRP dosing tank 01 No of 500 Ltr each and agitator assy with motor capacity min 0.5 HP, 230V, AC, 50 Hz.Complete with electrical connection, wiring, starter and piping work with other accessories as required complete all as specified and directed. (vi) Iron Removal Filter Plant :Qty -01 No : It shall be vertical type, cylindrical shape of MSEP having shell thickness of min 6 mm, dish end thickness min 8 mm, filled with filter media sand and Mno2in layer of min 600 mm each, Having min flow rate – 46m3/hr, Design pressure – 4Kg/cm2, Test pressure – 6 Kg/cm2including PCC foundation work with grouting bolts and arrangement (as specified by OEM) for erection of and installation of plant complete including all connected piping work by providing MS pipe class C heavy duty of suitable size as recommended by OEM. (vii) Post Chlorination Doser : Qty : 02 Nos (1No working + 1No Standby): It shall having Mechanical actuated diaphragm metering pump of flow rating 1-10LPH, Min Pressure rating 3.5 Kg/cm2, Dosing motor – TEFC, min cap 0.25 HP, Single phase AC, 230V, 50 Hz, chemical resistant FRP tank (5mm thick) of 200 ltrs -01 No, agitator assy having motor cap 0.25 HP, Single Phase, 230V, AC, 50 Hz complete with electrical connection, wiring, starter and necessary piping work with other accessories as required complete all as specified and directed by EIC. Item Continued as 11.38
NOTE :- (i) Contractor shall take the approval of make of plant from GE before procurement and submit the General arrangement drawing of water treatment system, line plan of pipe lines with Loc of valves, NRV, air release valve and their arrangements and take approval of GE before procurement & starting the filtration plant work. (ii) The unit rate of item includes complete piping work for inlet, outlet, back wash system, of Heavy duty MS pipe of suitable size including providing connections and all fittings required at site, supply and fixing of butterfly type inlet/outlet valves, check valves (NRV) and air release valves at inlet/outlet and backwash system pipe line and all accessories as required at site complete, including painting of pipe line with colour code all as directed and required at site and directed by EIC. (iii) Contractor shall provide Control panel with starter for all the pumps and motors, dosing pump, agitator etc with cables from control panel to each individual pump/motor without any extra cost. (iv) Contractor shall provide CPVC pipe of min 15mm bore (size as recommended by OEM for free flow of solution from dosing plant to end destination) and suitable size for inlet./outlet pipe of pre chlorination, post treatment chlorination, Alum mixture and soda ash tank to water treatment plant i.e sedimentation tank & clear water sump complete. Item Continued as 11.39
Supply, installation, testing and commissioning of "outdoor cubial type" LT Distribution Board of suitable size factory fabricated CPRI approved with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protecton not less than IP-43/42 and general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15mm thick CRCA sheet duly pre-treated & powder coated, supporting frame angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring incl cable glands of suitable sized incl PCC platform/plinth of sutiable size complete all as specified & as directed with & incl the following accessories : (BOREWELL PANEL) The busbar shall be made up of 04 Nos copper busbar 100A rated duly insulated with 1100 V Grade standard colour coated PVC sleeves and rigidly mounted on suitable sized 'F' class insulators of non hygrosopic, all internal connections from main busbar to switch gear etc. Item Continued as 11.42
INCOMING/OUTGOING/INSTRUMENTATION SYSTEM (a) Incoming MCCB 4P having breakin capacity 16 KA of rating 63A adjustable type thermal magnetic release - 01 No. (b) Indicator lamp LED type (Red, Yellow, Blue) - 01 Set (c) Submersible pump starter fully automatic, star delta starter suitable for submersible Pump set (as In item No 10.17 above but not less than 15 HP), 3P, 415V, 50Hz with max relay range 28-42 Amp having dry run, over load protection, single phase preventer, Phase reversal protection with Ampere meter complete all as specified and directed.
Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
M&L for fittings ISI marked of size upto 100 mm/150mm bore sutiable for DI pipes class K-12, with inside cement mortar lining and black bitumen external coating, such as bends (any tupe radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed.
S&F LED light 1X10 W (or nearest next higher wattage), 700K, wall/ surface mounted, integrated type with aluminium housing and caps with integrated high efficiency electronic driver and surge suppessor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range -140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws complete all as specified and directed.
S&F Eenergy saving and environmental friendly long life LED 20 watt building security light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening with driver compartment, lP66 protection with other accessories and necessary electric connection complete all as specified and directed.
S & F MCB DB blanking plate complete all as specified and directed.
S & F Wall mounting fan 300mm sweep, single phase 230 volt complete all as specified and directed.
M&L for earthing with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth strip protected by and including PCC (1:2:4) type B1 precast RCC cover slab (M-15) reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI wire protection & common salt, charcoal in alternate layers and test point terminal box complete all as shown in EP No 3 of SSR Part 1 2009 and testing on completion complete including dismantling the existing unserviceable earthing complete all as specified and directed.
Supply and fixing of bracket for street light/security light fitting fabricated with 1200 mm long and 32/40 mm bore medium grade GI pipe bent to shape as required and fixed in position including necessary clamps,nuts,bolts & washer all as specified and directed.
M&L for three core pvc insulated weather proof aluminium conductor cable of size 2.5 sqmm for connection street light ot overhead conductor complete all as specified and directed.
S&F of transparent street light junction box of size 200mmx160mmx 98mm made of high quality polycarbonate ip-65(dust & powdered Jet proof according to IEC60529), shock proof, corrosion free, Acid & chemical resistant, fire retardant having high impact (IK-08) totally insulated (CLASS-II) made of halogen and silicate free recyclable material, UV resistant having high grade gasket made of Polyurethane with copper busbar 25x25mm-4strip, one No MCB DB 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M-32 gland suitable upto 50sqmm cable etc complete all as specified and directed.
S&F of busbar panel board fabricated with 2mm thick CRCA sheet, having Aluminum busbar of rating 200 Amp with dimension of panel 800 mm (H) x 600 mm (W) x 35 mm (D) all as specified and directed.
Supply & fixing Auto timer switch for auto ON/ OFF of street lights in sheet steel enclosure, including all accessories like contactor, digital timer switch, MCB - 40Amp, pre wired, of 40 Amp, 3 Pole, 230 Volt, including making all electrical connections, fixing of timer switch box by providing all hard ware as required complete all as specified and directed .
Supply, fixing, installation, commissioning and testing Servo controlled Voltage stabilizer For automatic operation of 50 KVA capacity confirming to BIS 9815: Oart 1 : 1994 reaffirmed 2009, 3Phase, 50 HZ, Naturally oil cooled, Indoor type, unbalanced type, copper wound, with digital display type Relay, free smooth and silent operation with 1st fill of transformer oil (IS335:1993, reaffirmed 2005), IP 42 designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second having following specification complete all as specified and directed. (i) Input Voltage 300 Volt -480Volt. (ii) Output voltage stabilized at 415 V + 1%(Adjustable). (iii)Rated frequency 50 HZ. (iv) No distortion wave form. (v) Respond time shall not to exceed 10 Millisecond. (vi) Sensitivity (+) 1 %. (vii) Rate of correction 8 Volt /Second for single Phase and 20 Volt / Second for Phase to Phase. (viii) No load losses less than 0.5% and full load losses less than 2.5%. (ix) Duty cycle Continuous 24 x7. (x) Efficiency more than 95%. (xi) Type of load: 3 Phase, unbalance type. (xii) Digital Volt meter and Ampere meter. Item Continued as 15.57
Protection: (i) Overload/ Short circuit protection. (ii) High /Low voltage cut off. (iii) By pass arrangement in case of emergency. (iv) Single Phase sequence change protection. NOTE: (i) Contractor shall take the approval of Make of Stabilizer before procurement from GE. (ii) Contractor shall submit general arrangement drg of stabilizer and get approval of GE before placing order. (iii) Test certificate and Purchase voucher to be submitted by contractor before claiming payment.
Sub total
MEGHALAYA CONSTRUCTION AND SUPPLY CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .