Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹38.7 L+₹90,497.50 (2.40%)Rejected-AOC 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹38.8 L+₹99,395 (2.63%)Rejected-AOC | L3 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
₹39.2 L
EMD Value
₹78,400
Closing Date
22 Nov 2021, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8305 PROVN OF INFRASTRUCTURE FOR OXYGEN GENERATION PLANT AT AICTS PUNE UNDER GE SOUTH PUNE
2021_MES_484986_1
8305 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
90 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹78,400
Yes
21 Dec 2021
29 Oct 2021
24 Nov 2021
29 Oct 2021
22 Nov 2021
10 Nov 2021
Amount
Excavation of post holes (or similar holes) each not exc 0.5 Cum & getting out, returning, filling and ramming earth or broken rubble mixed with earth around in hard/dense soil complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggreagate) as in foundations fillings and mass concrete complete all as specified and as directed.
Removing excavated material exceeding 50 mtrs and n.exc 250 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm (soils) complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St. 240 complete all as specified and as directed.
S&F MS structural steel like channel, angle, steel square tubes confirming to IS Fe-410 W fixed independently without connecting plates etc. for gate and similar work complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coated 150 gms GI based corrugated steel sheet 0.50 mm thick fixed in any position where directed of any colour having tensile strength of 550 Mpa, high gloss, as in roof covering/cladding to wall, fixed with self tapping screw with one corrugated side lap, bent to shape complete alla as specified and as directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified incl dismantling of old sheet complete all as specified and as directed
Preparation new steel surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed.
M&L for PCC in foundation in 1:4:8 type D2 (40mm garded agg) in foundation filling and mass concrete complete all as specified and as directed.
M & L for Moorum / red bajri filling in floors or pavings laid in layers n.exc 15 cm thick spread levelled & rammed including watering complete all as specified and as directed.
M&L for rendering 15 mm thick CM (1:4) on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for rendering 15 mm thick CM (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for applying two coats of cement base paint over a coat of alkali resistant primer on walls including preparation of new plaster surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion over a coat of chalk whiting on plastred surfaces, preparatory walls including preparation of new plaster surfaces complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for precast cement concrete interlocking paver blocks, coloured, glossy finish with any shape and size conforming to IS-15658-2006, 60mm thick, M-35 grade, laid over & including 75mm thick stone dust/grit all as specified and as directed.
M&L for 150 mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / foundation complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type D-2 (using 40mm graded stone aggregate) as in flooring complete all as specified and as directed.
S&F expanded metal cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.90 mm dia or fixing with galvanised steel staples supplied and fixed complete steel members weight of expended metal per sqm area should be exc 4kg complete all as specifed and directed.
M&L for Distribution copper pipe Copper Pipes Solid drawn, seamless, deoxidised, non-arsenical, half hard tempered and degreased, fittings should be End-feed type, made from the same grade of copper as the pipes, and in accordance with the requirements materials manufactured as per BS EN 13348:2001 standard alongwith third party inspection certificate from Lloyds',SGS,TUV. (All exposed pipes to be painted with two coats of synthetic enamel paint, the color, To marked with the name and / or symbol adjacent to shut-off valves, at the junctions and the changes of direction, before and after walls and partitions, etc. at the intervals of no more that 10M and adjacent ,Marking to include arrows denoting direction of flow and letters used for marking shall not be less than 6mm high.
Item No. 23.00 Contd.... All concealed pipes to have gas identification bands/ labels are appropriate distance, similarly all pipes which need embedding in the wall will to be tested/ painted/ labled and properly insulated in accordance with ISO 5359.After erection, the pipelines are to be flushed and purged clean with dry nitrogen gas. Pressure testing using dry nitrogen gas at 1.5 times the working pressure for atleast 24 hours. System should exhibit its integrity and no-leakage. All contraindications, if any, to be carefully examined, problems diagnosed and necessary rectifications/ substitutions carried out, and test repeated after re-purging the lines. codification complying with ISO 5359 / IS 2379 complete all as specified and as directed.
76 mm OD x 0.9mm thick
54mm OD x 0.9mm thick
42mm OD x 0.9mm thick
35 mm OD x 0.9mm thick
28 mm OD x 0.9mm thick
22 mm OD x 0.9mm thick
M&L for Isolation Ball Valves with Brass adapters for area/regional isolation Working temperature Minimum: (–30°) Maximum : (180°) Brass bodied along with ball, stem, stem eal, Teflon Seal and ‘O’ ring. Connecting The ends of the valve have flare nipples which can be connected to copper pipe of respective outer diameter with the help of a flare nut complete all as specified and as directed.
M&L for reducer flange 76mmx65mm made of Stainless steel of medical grade all as specified and directed
M&L for Analogue Gas Alarms system with fittings for the following :-
For Oxygen Gas
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth (for cable, pole, stay etc) not exc. 10 sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 m in depth for foundation and getting out in Hard/Dense soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 m in depth for foundation and getting out in Hard rock complete all as specified and directed.
Returning filling in incluiding spreading levelling watering and well ramming in layers not exc 25 cm (Rock) complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point (Rock)
M&L for laying reinforced concrete pipes, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be levelling all as specified and directed.
Supplying and laying GI pipe, 100 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supply and laying & testing and commisioning LT underground cable 1100 Volts grade, XLPE insulated and PVC sheathed heavy duty armourd with multi stranded aluminium condutor laid in pipes, of 3.5 core x 240 sqmm.
M&L for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (Eearth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 meter below normal grond level, Connected to GI strip 32 x 6 mm (Upto the body of equipment) by means of GI bolts / nuts / washer proteted by 40 mm bore GI mediumgrade pipe, Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top 20 mm bore GI Pipe mediaum grade pipe for watering including funnel, wire mesh, RCC cover and frame, PCC(1:3:6) Type C2 (using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work all as specified and shown in electrical plate No 5 of MES schedule Part- I connectoed to earthing test including testing on completion complete all as specified and as directed.
S & F MCCB - 250 Amp, 4P, 36KA with thermal & magntic release in existing LT Control panel at substation complete all as specified and directed.
Supply and installing testing and commissioning of outdoor type free standing weather proof, dust and vermin proof LT Cable / Modular construction fully compartmentalized panel with bus bar chamber and cable ally on both on side, IP -54 as per all as per IE rules fabricated with 3.0 mm CRCA double door type (Front side ; out side with main panel door and inside with compartmentlised door for each cubicle) Rear side main panel door and inside bolted door for each cubicle) Sheet for load bearing members and 2 mm thick for doors and covers and shall be powder coated with 7 tank process on all internal external surface. The panel to be suitable for 1100 volt grade 3 phase, 415 volts, 50 Cycle AC Supply. The panel shall be provided with MS Angle iron frame 50 x 0 x 6 mm welded in shape and including necessary grouting in PCC 1:3:6 type C-1 with 20 mm grade stone aggregate complete with legs 30 cm in ground in pcc and 40cm above ground including connecting to cable with gland, lugs etc and comprising the following:-
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & pvc conduit,including of junction and terminal boxes, all fittings such as tees, bends, elbows, reducers, bell mouth tube endsn , couplers, lock nuts, saddles pipe hook, etc. of External diameter 20mm all as per site requirements including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified For one light point / fan point controlled by one switch
All as per item no. 1 above but for One socket outlet 5 Amp controlled by one switch on the same board.
All as per item no. 1 above but for One socket outlet 5 Amp controlled by one switch on the independent board.
All as per item No. 1 above but using 2.5 sqmm copper conductor for with 1.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
S&F switch piano type flush, single pole, one way,5Amp 230 Volt complete all as specified and as directed.
S & F socket outlet 5 pin, 5 Amp 230V, complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Ampflush type universal, complete all as specified and directed.
S&F ceiling rose,pvc surface backlit, 63.5x48 mm three terminal complete all as specified and as directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete all as specified and as directed.
S&F testing and commissioning of MCB SPN 240 volt 16 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.
S&F testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.
Supplying ,Laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable of size 16 sq mm,4 core, 1100 volts grade ,laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix street light fittings Pressure die cast aluminium housing, IP 66 Proptection, heat resistance toughened glass with frame LED street light luminaries complete with driver and all standard accessories of capacity 25 Watt LED including necessary fixing arrengements with GI Pipe 25mm and MS clamp 02 Nos, necessary connection etc complete all as specified and directed
Supply, install testing and commissioning of factory made wind driven turbo ventilator (mill finidh) of throat size 600 mm width FRP base to match roofing sheet with necessary fixing and jointing material for leak proof joint and variable angle elbow including cutting of existing sheet for fixing of turbo ventilator and safety precautions measures to be included inquoted rate complete all as specified and directed.
M/s.BAJRANG CONSTRUCTION
SHINDE DHEERAJKUMAR SIDRAM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .