RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Emergency Lighting And Accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower Type With AC Genset) ( 18 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Portable emergency lighting system consisting one Gen set
RequiredYes * 1/8 Tower/Telescopic collapsible mast/Vertical mast
RequiredLED Luminaire
RequiredSupporting kits
RequiredTool Kits
RequiredStorage box for tool kit (Tool kit list to be furnihed by seller at the time of supply) Rating of Generator set (in KVA) (Minimum) 0.5 KVA 0.5 KVA
Required1.0 KVA
Required2.0 KVA
Required3.0 KVA
Required5.0 KVA
Required6.0 KVA
Required8.0 KVA Number of cylinder in the Engine 2 Cylinder 2 Cylinder
Required3 Cylinder Minimum continuous working hours 8 hours 2 hours
Required4 hours
Required8 hours
Required10 hours
Required12 hours
Required30 hours
Required60 hours
Required90 hours
Required100 hours Gen set fuel tank capacity (Minimum) - in litres 3 litres 3 litres
Required5 litres
Required7 litres
Required10 litres
Required20 litres
Required40 litres
Required80 litres
Required100 litre
Required120 litres Type of fuel Petrol Petrol
RequiredDiesel Minimum System Lumens 50000 * IP rating of LED Luminaire IP67 * Ruggedised Storage Box for main equipment Yes * TOWER CONSTRUCTION Minimum height of Tower/Telescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) 4 4
Required5
Required6
Required7
Required8
Required9
Required10
Required12 Material of Tower/Telescopic collapsible mast Vertical Mast Mild steel Aluminium
RequiredMild steel
RequiredGalvanised Iron
RequiredFiber Minimum thickness of Tower/Telescopic collapsible mast/Vertical Mast material (+/-5%) 3 mm * Method of step up and step down of Tower Telescopic collapsible mast/Vertical Mast Manual * 2/8 Step up and step down time of Tower Telescopic collapsible mast/Vertical Mast </=2 Minutes * The strength of the Tower/Telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain erect at wind speed of 40 km/hr * GENERATOR SET CONSTRUCTION Generator Set: Recoil start portable AC Generating set comprising AC Generator with declared rating 230 V Single Phase of unit power factor conforming to IS:13364 (Part 1/92) and petrol run air cooled four stroke single cylinder engine with resettable circuit breaker in the AC output Yes * Type of mounting With trolley With out trolley
RequiredWith trolley Engines shall conforming to IS:7347/1974 (Reaffirmed in 2006) latest Yes * Alternator shall conforming to IS: 13364 (Part 1)/1992 (Reaffirmed 2003) latest Yes * System should work on 220/230V
Required50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes * LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * 3/8 Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * LED Modules as per the IS: 16103(Part-2)/2012 Yes * Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) >/= 50
Required000 burning hours * Colour Rendering Index(CRI) ≥70 * Optic lense materal (UV stabilised) Poly carbonate lense * The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Extruded silicon loop gasket shall be provided to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat Yes * 4/8 and ageing within warranty period Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Operating temperature range -20 deg. C to +50 deg. C * "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * Date of manufacture (month-year)
Requiredand lot number as identification mark inside of each unit Yes * REPORTS AND CERTIFICATIONS Availability of type test reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine
RequiredAlternator and Luminaires as per relevant IS specifications as applicable Yes * Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes * Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report Yes * 5/8 from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as applicable as on date Yes * Total Weight of complete system (Must declare) in Kg </=100 Kg * Warranty for complete system 2 Years * * Bold specifications are the golden parameters.