Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹17.9 L+₹25,550 (1.45%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹19.7 L+₹2.1 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹20.0 L+₹2.4 L (13.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT OF ELECTRIC STORAGE HEATER AND ALLIED WORKS IN CAMP AREA AND 4 AREA UNDER GE AF ADM AREA AT AF STATION AGRA
2021_MES_479909_1
8000-1912/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹40,000
Yes
23 Nov 2021
6 Oct 2021
3 Nov 2021
6 Oct 2021
1 Nov 2021
20 Oct 2021
6 Oct 2021 - 19 Oct 2021
60 days
Amount
Comprehensive repair/maintenance of storage type electric water heater (geyser) of capacity 25/50 litres, vertical or horizontal type comprising of the following: (a) Opening or dismantling the storage tank, taking down, de-scaling, brushing and thoroughly cleaning. (b) Replacement of defective parts. (c) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and replacing of washers/ gasket nut etc. (d) Checking and rectify earth continuity of the Electrical circuits of Geyser and power point. (e) Checking and re-fixing thermostat and re-adjust. (f) De-scaling the immersion type heating element and siphon assembly with diluted Hydrochloric acid or clear pedette solution. (g) Checking of indicator lamp for it proper serviceability. (h) Re-assembling the Geyser and re-install at same position and testing complete all as specified and directed. NOTE: (i) Unserviceable Parts/ components of water heater shall be replaced by the contractor. (ii) Supply and fixing of new inner SS water tank, syphon assembly, outer body, glass wool, indicator lamp shall be measured and paid separately under respective item of schedule as supply only.
Supply only stainless steel inner tank of storage type electric water heater of 25 ltr capacity complete with rubber gasket including necessary nuts, bolts and washers complete all as specified and directed.
Supply only stainless steel inner tank of storage type electric water heater of 35/50 ltr capacity complete with rubber gasket including necessary nuts, bolts and washers complete all as specified and directed.
Supply only syphon assembly made out of stainless steel of 25/ 35 ltr capacity geyser as per existing sample including necessary studs, screws and rubber gasket/ washers matching with existing/ new inner tank complete all as specified and directed.
Supply only syphon assembly made out of stainless steel of 50 ltr capacity geyser as per existing sample including necessary studs screws and rubber gasket/ washers matching with existing/ new inner tank complete all as specified and directed.
Supply only outer body made out of MS sheet suitable for 25 ltr capacity geyser as per existing sample duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply only outer body made out of MS sheet suitable for 50 ltr capacity geyser as per existing sample duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply only glass wool of 25/50 ltrs capacity storage type electric water heater complete all as specified and directed.
S&F in replacement geyser element 1.5 KW triangular/ round (as per approved sample) ISI marked and compatible with existing geyser complete all as specified and directed.
S&F in replacement of heating coil element for geyser 2.0 KW triangular/ round (as per approved sample) without assembly of ISI marked and compatible with existing geyser complete all as specified and directed.
S&F in replacement of PVC flexible connection pipe 450 mm long for hot and cold water connection complete all as specified and directed.
S&F in replacement of PVC insulated copper conductor 3 core cable of size 2.5 sqmm and its connection complete all as specified and directed.
S&F in replacement of thermostat adjustable type between 300C to 850C of ISI marked and compatible with existing geyser complete all as specified and directed.
Supply only lamp for geyser suitable for 25/35/ 50 ltrs capacity complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/ 50 ltrs capacity geyser complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed/concealed complete to walls and ceilings or laid in floors and testing complete all as specified and directed.
S&F anchor bolt 12 mm x 100 mm long complete all as specified & directed. Note:- Anchor bolt shall be grouted with hammer drill only.
S&F in replacement of existing U/S brass non return valve suitable for 25/ 50 ltr capacity storage type electric water heater of size 15 mm complete all as specified & directed.
S&F in replacement of U/S bottom cover plate of storage type electric water heater of capacity 25 ltr & fixed with MS screws complete all as specified & directed.
S&F in replacement of U/S bottom cover plate of storage type electric water heater of capacity 50 ltr & fixed with MS screws complete all as specified & directed.
S&F in replacement of U/S CP brass wall mixer two way of 15 mm bore of pipe for mixing of hot and cold water screwed down or Iron pipes and fixed complete(Surface/Concealed all as per site requirement) as specified and directed.
S&F in replacement of U/S sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F in replacement of U/S metallic plug top suitabe for sheet metal enclsoure 20 Amp capacity complete all as specified and directed.
S&F in replacement of U/S plug top 3 pin 15 Amp 240 Volts ISI marked complete all as specified and directed.
S&F in replacement of U/S MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
S&F in replacement of U/S MCB SPN 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
Taking down old unserviceable copper/ aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/ casings & caping complete, including fixture and fittings such as switches, ceiling roses, pendents holder, regulators, sockets and defective main switch/ DB/ MCB/ Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M&L for point wiring complete fixed independently suitable for 15 Amp socket point with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 2.50 sqmm nominal cross sectional area single core drawn in and including 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3 mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 2.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
S&F in replacement Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F in replacement socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 15/16 Amp, 230 volts complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 15/16 Amp, 230 volts complete all as specified and directed.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
jmd engineers
Balaji Associate
TRIVENI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .