Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹22.2 L+₹4.6 L (26.0%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹32.4 L+₹14.8 L (84.1%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS Rajouri
REPAIR REPLACEMENT OF CERTAIN PARTS OF SUMMER AND WINTER APPLIANCES INCLUDING REPAIR REPLACEMENT OF BUILDING, LIGHTNING ROTECTION SYSTEM AND CONNECTED EARTHING AT DETT-B AND DETT-III AREA UNDER AGE EM OF GE 862 EWS
2024_MES_672019_1
GER-52/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS Rajouri
As per Tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹80,000
Yes
18 Nov 2024
5 Sept 2024
7 Oct 2024
5 Sept 2024
4 Oct 2024
20 Sept 2024
5 Sept 2024 - 16 Sept 2024
Amount
REPAIR TO GEYSER Taking down/ dismantling of defective/rusted storage type hot water heater/ Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts such as glass wool, element, water tank, flange assembly, gasket of any type, nuts/bolts, clamp by unscrewing bolts and nuts, de-scaling/cleaning internally and externally including checking for leakage in tank and rectification by gas welding as required etc. Checking defects, re-assembling and re-installing the Geyser in position after complete servicing, connection and testing to entire satisfaction of Engr-in-Charge. Note:-(i) Cost of gas welding, nuts/bolts, clamps, shall be deemed to be included in the quoted rate by tenderer. (ii) Replacement of unserviceable parts shall be measured and paid separately under respective items.
Supply and fixing of Heating element 2.0 KW (ISI marked) round/triangle shape complete all as specified and directed.
Supply and fixing of Heating element 1.0/1.5 KW (ISI marked) round/triangle shape complete all as specified and directed.
Supply and fixing of Heating element 3.0 KW (ISI marked) (for solar water heater) complete all as specified and directed.
S&F for PVC insulated and unsheathed multi - stranded flexible wire 3 core with Copper conductor 2.5 Sqmm round type for Geyser complete all as specified and directed.
S&F for Thermostate of range 60-90 degree centigrade adjustable type operative on 250 volts complete all as specified and directed.
S&F for Indication lamp (Green/Red) round/ square as per requirement and complete all as specified and directed.
S&F of Inner tank made out of stainless steel of standard gauge suitable for 25/35 litres capacity geyser as per existing make complete all as specified and directed.
S&F of Inner tank made out of stainless steel of standard gauge suitable for 50 litres capacity geyser as per existing make complete all as specified and directed.
S&F of geyser syphon assembly chromium plated suitable for 50 ltr capacity geyser ISI marked complete all as specified and directed.
S&F of geyser syphon assemble chromium plated suitable for 25/35 ltr capacity geyser ISI marked complete all as specified and directed.
S&F in replacement PVC connection 15mm dia (heavy duty) with two nos of brass adaptor and washer of size 450mm to 600mm long for hot/cold water suitable for geyser complete all as specified and directed.
S&F in replacement for sheet metal enclosure with socket plug top and MCBs single pole with one MCB 240 volts 20 amps, complete all as specified and directed.
REPAIR TO CEILING/EXHAUST FAN Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep and, exhaust fan/pedestal fan/air ciculating fan any sweep from various building (or collecting from MES E/M store yard), opening up for servicing /repair , removing dust and dirt, cleaning fan motor with cotton/waste malmal, washing blades with detergent powder, greasing to serviceable bearings, checking of nuts , bolts, washer, rubber buff, split pin, condensor, MS clamps, rubber packing, condensors block, rubber reel etc for any damages and replacement of damaged and unserviceable items for the smooth and satisfactory functioning, refixing fans etc in same position connecting to electric system and testing complete all as specified and directed. (Note :- Replacement of damaged /unserviceable part shall be measured and paid separetaly).
Rewinding of AC ceiling fan motor 240 volts, 50Hz, 1200mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
Rewinding of AC ceiling fan motor 240 volts, 50Hz, 1400mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
Rewinding of exhaust fan motor 240 volts, 50Hz, 300mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
Rewinding of exhaust fan motor 240 volts, 50Hz, 450mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
S&F of Capacitor AC 415 volts 4 MFD 50 Hz complete all as specified and directed.
S&F of Capacitor AC 415 volts 2.5/3.15 MFD 50 Hz complete all as specified and directed.
S&F of fan blade set of 1200mm sweep ceiling fan (as per sample colour/white) complete all as specified and directed.
S&F of fan blade set of 1400mm sweep ceiling fan (as per sample colour/white) complete all as specified and directed.
S&F in replacement for PVC insulated and unsheathed multi - stranded flexible wire 3 core with Copper conductor 1.5 Sqmm for connecting connector block to ceiling rose and making connection complete all as specified and directed.
S&F in replacement for PCB (printed control board) and sensor for BLDC motor ceiling fan 1200mm as per existing make complete all as specified and directed.
REPAIR TO REFRIGERATOR Dismantling of refrigerant of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor/ freezer units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F hermetically sealed compressor unit 1/8 HP for 165/175 Ltr capacity of refrigerator of existing make/ model in the unit complete all as specified and directed.
S&F hermetically sealed compressor unit 1/6 HP for 280/310 Ltr capacity of existing make and model of refrigerator complete all as specified and directed.
S&F in replacement for PCB (printed control board) and sensor for refrigerator complete all as specified and directed.
Supply & filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters of any type complete all as directed by Engr-in-charge.
S&F of starting relay for domestic refrigerator of any capacity, complete all as specified and directed by Engr-in-charge.
S&F of over load protection for referigerator of any type and capacity complete all as specified and directed by Engr-in-charge.
S&F of thermostat for refrigerator of any type/capacity complete all as specified and directed by Engr-in-charge.
REPAIR TO WATER COOLER Dismantling of water cooler of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F of hermetically sealed compressor unit 1/6 HP for 80/120/150 Ltr capacity water cooler of existing make/ model in the unit complete all as specified and directed.
Supply & filling of refrigerant gas R-22 of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters of any type complete all as directed by Engr-in-charge.
S&F for starting capacitor 60/80 MFD 230 volts AC for water cooler capacity 80/120/150 ltrs complete all as specified and directed by Engr-in-charge.
S&F for running capacitor 15 MFD suitable for water cooler of capacity 80/120/150 ltrs complete all as specified and directed by Engr-in-charge.
S&F for thermostate suitable for water cooler of 80/120/150 ltrs capacity complete all as specified and directed by Engr-in-charge.
S&F for starting relay suitable for water cooler of 80/120/150 ltrs capacity complete all as specified and directed by Engr-in-charge.
REPAIR TO AC WINDOW TYPE Dismantling the window type AC of capacity in 1.5 Ton in various location, shifting it to MES Yard and taking out compressor/condensor unit/blower motor etc for repair/replacement of unserviceable spares parts and cleaning condensor unit from foreign particles, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and sticking a sticker mentioning the ‘No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by thermocol, ply wood, wooden bit all as directed & specified by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
M&L for complete servicing of window type AC of capacity in 1.5/2 Ton at various locations disconnecting setting aside cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling, testing and fixing the same by thermocol, ply wood, wooden bit at same location complete all of the satisfaction of Engr-in-Charge.
S&F hermetically compressor sealed unit with referigerant gas of suitable capacity / model in the unit properly for 1.5 Ton window type AC complete all as specified and directed by Engr-in-charge.
S&F blower fan motor double shaft, 3 speed, single phase, AC, 1/5 HP, 920 RPM, 220 Volts as per existing make of window type AC 1.5 Ton complete all as specified and directed by Engr-in-Charge.
S&F in replacement for starting capacitor 100/120 MFD 230 V AC for window type AC 1.5 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F of Starting relay (SR-1622) suitable for window type AC 1.5 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F strip type heater (M-type), 2KW for window type AC 1.5 ton capacity as per existing make and model complete all as specified and directed.
S&F for running capacitor 36 MFD, 230 V for window type AC 1.5 Ton capacity complete all as specified and directed by Engr-in-Charge.
REPAIR TO AC SPLIT TYPE Dismantling the split type AC of capacity 1.5 to 2 Ton in various location, shifting it to MES Yard and taking out compressor/condensor unit/blower motor etc for repair/replacement of unserviceable spares parts and cleaning condensor unit from foreign particles, cleaning of filter (if not replaced) of split type AC of any capacity by vacuum cleaner/water spray/mild liquid soap and sticking a sticker mentioning the ‘No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
M&L for complete servicing of split type AC of capacity in 1.5/2 Ton at various locations disconnecting setting aside cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling, testing and fixing at same location complete all of the satisfaction of Engr-in-Charge.
S&F of condensor fan motor per existing make/model of split type AC 1.5/2 Ton complete all as specified and directed by Engr-in-Charge.
Rewinding blower motor with super enameled copper winding wire of standard gauge including replacement of ball bearing, insulating material for existing make/model of split type AC 1.5/2 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement for PCB (printed control board) dual mode and sensor for split type AC 1.5/2 Ton as per existing make complete all as specified and directed.
S&F of running capacitor 40/50 MFD capacity, 230 Volts for split type AC 1.5 / 2.0 ton capacities complete all as specified and directed.
S&F of hermetically sealed compressor unit for 1.5 ton capacity split type AC of existing make/ model complete all as specified and directed.
S&F of hermetically sealed compressor unit for 2 ton capacity split type AC of existing make/ model complete all as specified and directed.
Supply and filling of refrigerent gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters, complete all as specified and directed.
REPAIR TO DEEP FREEZER Dismantling of deep freezer of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor/ freezer units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F of hermetically sealed compressor unit 1/6 HP for 310 Ltr capacity of deep freezer of existing make/ model complete all as specified and directed.
S&F of starting relay suitable for deep freezer of any capacity complete complete all as specified and directed by Engr-in-charge.
S&F of over load protection for deep freezer of any type make and capacity complete all as specified and directed by Engr-in-charge.
S&F of thermostat for deep freezer of any make and capacity complete all as specified and directed by Engr-in-charge.
S&F of filter suitable for deep freezer of any make and capacity complete all as specified and directed by Engr-in-charge.
S&F of condensor fan motor suitable for deep freezer of any make and capacity complete all as specified and directed by Engr-in-charge.
Repairs to industrial type RO plant of capacity 500 liters per hour of any type and make by dismantling and carry out servicing, descaling and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalant dosing system etc and replacement of spare parts/components viz 500 GPD membrane, filter set, adoptor, motor, solenoid valve, and pipe coupling set and testing of water sample from certified for its performance complete all as specified and directed. Note:- (i) 500 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only.
Supply only 500 GPD membrane suitable for reverse osmosis (RO) plant of capacity 500 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only filter set suitable for reverse osmosis (RO) plant of capacity 500 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only adopter suitable for reverse osmosis (RO) plant of capacity 500 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only solenoid suitable for reverse osmosis (RO) plant of capacity 500 liters per hour of existing make and model of RO plant complete all as specified and directed.
Repairs to industrial type RO plant of capacity 100 liters per hour of any type and make by dismantling and carry out servicing, descaling and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalent dosing system etc and replacement of spare parts/components viz 100 GPD membrane, filter set, adopter, motor, solenoid valve, and pipe coupling set and testing of water sample from certified lab for its performance, complete all as specified and directed. Note:- (i) 100 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only.
Supply only 100 GPD membrane suitable for reverse osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only filter set suitable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only adopter suitable for reverse osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant complete all as specified and directed.
Supply only solenoid suitable for reverse osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant complete all as specified and directed.
S&F in repair of single pointed air termination aluminium rod 12mm dia and 300mm long on the highest point of the building on porcelain base support and making termination roof / down conductor with necessary aluminium screws/ nuts, bolts etc, complete all as specified and directed.
S&F in repair of single pointed air termination copper rod 12mm dia and 300mm long on the highest point of the building on porcelain base support and making termination roof / down conductor with necessary aluminium screws/ nuts, bolts etc, complete all as specified and directed.
S&F in repair of test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw in FRP box duly locking arrangement inlcuding connecting down conductor and earth strip, complete all as specified and directed.
S&F in repair of aluminium strip of size 25x3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe with necessary fixing arrangement by providing porcelain base at 60cm interval and using cadmium plated fixing screws , complete all as specified and directed.
S&F in repair of copper strip of size 20x3.15mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe (for additional lead beyond 7.5meter per per earth, if so required at site) and interconnection to earth pits, complete all as specified and directed.
S&F in repair of GI strip of size 32x6mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe (for additional lead beyond 7.5meter per earth, if so required at site) and interconnection to earth pits, complete all as specified and directed.
M&L in replacement for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted.
M&Lfor earthing complete with copper earth plate electrode 600x600x3.15mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 20x3 thick copper strip for from earth electrode to test point/ equipment of upto 7.5 m whichever is less by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto test point/equipment upto 7.5m is included in the rate quoted)
M&Lfor chemical earthing pit with copper earth plate of size 900mm x 600mm x5mm thick buried directly in ground vertically to a depth not less than 4m below normal ground level, connected to & including 32 x 6 mm copper strip by means of nuts, bolts check nuts and washers made of copper and connected to test point including brazing and excavation and earth work in any type of soil, with charcoal 250 Kg, crystal salt 200 Kg, magnesium sulphate of 100 Kg and vegetable soil all around the plate 35 cm depth bottom to top of the plate full width of pin including PCC 1:3:6 type C1 in chamber of internal size 300mm x 300mm x 300mm with wall thickness 120mm and 700mm x 700mm x 150mm bed concrete, precast PCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/Sqm) with cast iron frame, funnel, with wire mesh, 25mm bore medium grade GI pipe, lugs, 80mm bore medium grade GI protection pipe, test point etc complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5m is included in the rate quoted)
S&F in repair for 40 mm bore galvanized iron GI tubing medium grade with all fittings and jointing & erecting the pipe for lightening protection at any height with flat angle support to base, complete all as specified and directed.
S&F in repair for 80 mm bore galvanized iron GI tubing medium grade with all fittings and jointing & erecting the pipe for lightening protection at any height with flat angle support to base, complete all as specified and directed.
M&L for PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in mass concrete and making good to disturbed portion, complete all as specified and directed.
S&F for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanized iron or steel wire and removing old unserviceable wire complete all as speicified and directed
KRISHNA ENGINEERING ENTERPRISES (BID ID -3128587)
M/S PARSHOTAM KUMAR GUPTA (BID ID -3117712)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .