Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.3 LAccepted-AOC MURUGAN KOIL STREET SEER SELVA MURUGAN NAGAR SELLIPET PUDUCHERRY | PONDICHERRY | PUDUCHERRY | 605001 | 1 | Accepted-AOC he is the lowest tender | |
| 2 | Rejected-Technical | - | Rejected-Technical he is not the lowest tender |
Tender Value
₹11.8 L
EMD Value
₹23,560
Closing Date
5 Jan 2021, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner
Villianur Commune panchayat office, villianur
Providing water supply line to the extension of Amirtha garden, Mahalakshmi nagar and perumal garden at Thondamanatham in Villianur Commune (4th call)
2020_DLA_7403_1
20-68/VCP/Engg/JE(O)/eten9
Open Tender
Civil Works
Works
90 days
Thondamanatham
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹23,560
16 Jul 2021
29 Dec 2020
5 Jan 2021
29 Dec 2020
5 Jan 2021
29 Dec 2020
90 days
Amount
Code No:2.10.1.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m - all kinds of soil - pipes,cables etc , not exceeding 80mm dia
code no 2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, withina lead of 50 m - all kinds of soil - pipes,cables etc , exceeding 80mm dia butnot exceeding 300 mm dia
code no.31.161.1D Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required esting equipment,including cost of solvent cement,UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 75mm dia.
code no. 31.161.1E Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specialssuch as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 90mm dia.
Code No. 31.106.1B Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site ,lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including costof solvent cement,UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 25mm dia.
31.173.1B Providing and fixing in position UPVC moulded saddle set (Finolex / jain)(0.6Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc,complete - 75 x 20mm dia
Code No. 15.2.1 Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead nominal concrete 1:3:6 or richer mix (i/cequivalent design mix)
Code No. 15.2.2 Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead nominal concrete 1:4:8 or leaner mix (including equal vent mix (i/cequivalent design mix)
Code No. 15.59 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometre
Code No. 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Code No. 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 4 graded stone aggregate 40mm nominal size)
Periyannasamy
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_7565.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .