Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.2 L+₹770.45 (0.03%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹22.2 L+₹10,316.47 (0.47%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹23.6 L+₹1.5 L (6.69%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹23.6 L+₹1.5 L (6.78%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹24.5 L
EMD Value
₹48,940
Closing Date
20 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
ADDN AND ALTN TO BLDG NO E147/1 AT NEW HASTING LINES OF MCEME UNDER GE MCEME SECUNDERABAD
2021_MES_477257_1
GE/MCEME/TOK/33 OF 21-22
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
Class E Category a(I)
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹48,940
Yes
24 Nov 2021
23 Sept 2021
22 Oct 2021
23 Sept 2021
20 Oct 2021
7 Oct 2021
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard rock complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils complete all as specified and directed by Engineer-in-Charge.
M&L for Treating the top surface of filled earth at rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete Type D2 1:4:8 (Using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 using 20 mm graded stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 using 20 mm graded stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 using 20 mm graded stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 using 20 mm graded stone aggregate in Chajjas complete all as specified and directed by Engineer-in-Charge.
S&F mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
S&F mild steel bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
S&F mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of rough finished flat surface of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of rough finished flat surface of concrete pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides and soffits of rough finished flat surface of concrete of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to rough finished flat surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to rough finished flat surface of concrete chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to edges of rough finished surface of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M&L for damp proof course 25mm thick, in cement concerte 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork etc.complete all as specified and directed by Engineer-in-Charge.
Forming jambs, etc. in cement mortar 1:6 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed by Engineer-in-Charge.
Cutting opening in cement concrete walls, with or without reinforcement (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. complete all as specified and directed by Engineer-in-Charge.
M&L Brick work with fly ash modular bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with fly ash modular bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement) with water proofing compound, complete all as specified and directed by Engineer-in-Charge. (Note : WPC will be measured and paid separately)
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement) with water proofing compound, including taking down old cement plaster complete all as specified and directed by Engineer-in-Charge. (Note : WPC will be measured and paid separately
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered wall surface and applying two coats of plastic emulsion over a coat of primer over two coats of wall care putty, complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment on wall surface and applying two coats of plastic emulsion over a coat of primer over two coats of wall care putty, complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment on wall and finishing wall with Premium Acrylic smooth exterior paint with silicone additives of required shade (Eq Apex Ultima) new work(two or more coats applied @1.43 ltr/10sqm over and including priming coat of exterior primer applied @2.20 kg/10sqm including preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L for finishing wall with Premium Acrylic smooth exterior paint with silicone additives of required shade new work(two or more coats applied @1.43 ltr/10sqm over and including priming coat of exterior primer applied @2.20 kg/10sqmr preparation of surface all as spd and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Spreading and levelling earth filling in floors in layers and well ramming including watering as required complete all as specified and directed by Engineer-in-Charge.
Hardcore of broken stone guage exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) , 100mm thick as in sub base in floor/paving etc. complete all as specified and directed by Engineer-in-Charge.
M&L providing cement concrete 1:2:4 type B1 (Using 20mm graded stone agg) , 25mm thick as in sub base in floor/paving etc. complete all as specified and directed by Engineer-in-Charge.
S&F non Skid Coloured ceramic Tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
S&F non Skid Coloured ceramic Tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed in CM (1:6) including dismantling existing tiles complete all as specified and directed by Engineer-in-Charge.
M&L coloured ceramic glazed tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc set in jointed in neat cement slurry over and incl 10mm thick cement screed in CM 1:3 and pointed to match the colour of tiles complete all as specified and directed.
M&L coloured ceramic glazed tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc set in jointed in neat cement sluury 10mm thick in CM 1:3 and pointed to match the colour of tiles including dismantling existing tiles complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down, Shutters of any description exc 1sq. M but n.exc 2.00 Sqm each, etc complete all as spd and directed.
S&F for Solid PVC frame (Single Rebated) of size 60x30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.complete all as specified and directed by Engineer-in-Charge. Note : Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life, etc complete all as spd and directed.
S&F Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications complete all as specified and directed by Engineer-in-Charge.
Supplied only liquid water proofing compound etc complete all as spd and directed.
S&F Windows/ventilators (NCL ECO–4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/powder coated (Base steel as per IS-513 “D” quality galvanized as per IS-277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm. Sections for Frame should be of 72x55mm, Section for Mullion should be of 72x50mm, Section for Shutter Frame should be of 47x20mm, Section for Fixed Glass Bead should be of 12x12mm, and Section for Fly Mesh should be of 40x20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges–1 set, Seccolor Handle & Seccolor Stay and 4mm Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6x12mm MS flat and fixed to window frame with screws complete all as specified and directed by Engineer-in-Charge.
S&F for Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. size of frame 125x60mm complete as specified and directed.
M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in filling in frame complete all as specifed and directed.
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick decorative laminated flush shutter with one face engraved and other face plain with lock rail, kiln seasoned and chemically pressed treated. The size of rail and stiles as per IS-1003 (Part-I) complete all as specified and as directed.
M&L for glazed and skeleton shutters 35mm thick 2nd class hard wood open rebated and prepared to receive glass, gauze etc divided into squares with plain chamfered or rounded or mitred and rebated sash bars any numbers, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass, sizes of members as specified in SSR Part I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
S/F Stainless Steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless Steel wire staples along with frame work of windows / ventilators with all necessary arrangements, complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new wood surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specifed and directed.
M&L preparation of old wood surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specifed and directed.
M&L preparation of new surface of steel any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specifed and directed.
M&L preparation of old surface of steel any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specifed and directed.
M&L for 3mm thick,Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sqm in each pane, etc complete all as specified and directed by Engineer-in-Charge.
M&L for 3mm thick, Sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, etc complete all as specified and directed by Engineer-in-Charge.
S&F for Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11d, size of hinges in 100mm, etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed, length of bolt in 100mm etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed, length of bolt in 200mm etc complete all as spd and directed.
S&F for Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed, length of bolt in 250mm etc complete all as spd and directed.
S&F 300mm, ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S&F for Brass handles, cast type, polished bright, Size of handle in 150mm, etc complete all as spd and directed.
S&F for Brass handles, cast type, polished bright, Size of handle in 100mm, etc complete all as spd and directed.
S&F floor door stopper of aluminium alloy body and tounge, anodised with hard drawn spring fixed in floor, overall length of cover plate 150mm all as specified and directed.
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 18-19mm thick prelaminated particle board, interior grade, prelaminated on one side with decorative choice lamination & other side balancing white laminationixed with beeding as in pelmet box, complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm long Brass Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11, etc complete all as spd and directed.
M&L for 18/19mm thick, Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, etc complete all as specified and directed by Engineer-in-Charge.
S&F for Brass handles, cast type, polished bright, Size of handle in 75mm etc complete all as spd and directed.
S&F 10 litre capacity, low level PVC flushing cistern, syphonic action type white colour with in let ball valve float and handle, PVC flush pipe, brackets etc complete all as specified and as directed by Engr-in-charge.
S&F in repairs, vitreous china wash basin white flat back size 550x400mm with brackets including cutting for and pinning in ends of brackets or erecting stand including waste coupling CP brass 32mm dia with long screwed shanks & fly nuts & fancy type CP pillar tap complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm size PVC Connection with CP Brass Nuts of length 600mm, complete all as specified and as directed by Engineer-in-Charge.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, aluminium snap beading, screws, aluminium fittings such as peg stays, 150mm long, hinges type B21 100mm long, suitable handle complete all as specified.
S&F mild steel galvanised tubes 15mm medium grade with all fitting, fixed to wall, ceiling or laying in floor.etc complete all as spd and directed.
S&F mild steel galvanised tubes 20mm medium grade with all fitting, fixed to wall, ceiling or laying in floor etc complete all as spd and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm bore complete all as specified and directed by Engineer-in-Charge.
S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-Charge.
M&L rotational moulded polyethylene water storage tanks (cylindrical verical with closed top) hoisted and fixed in position all as specified in 1000 ltrs capacity with 15mm HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and directed.
S&F PVC connection 15mm size, 450mm long with PTMP nuts both side, etc complete all as spd and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius with access doors 110mm borecomplete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius with access doors 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
M&L salt glazed stone wave gully traps square or rounded mouthed type & fix 150x 100mm fixed in cement concretecomplete all as specified and directed by Engineer-in-Charge.
M&L priming plastered roof surfaces with bituminous primer @ 0.3 Kg/sqm as per IS-3384 and providing water proofing treatment by applying 3.5 Kg/sqm actatic poly propylene (advanced App torch membrane with fiber glass and finished on top over and including rendering 10mm thick in CM 1:4 on concrete surfaces of roofs parapet etc, finishing to surfaces even and smooth with out using extra cement and providing necessary slope incl using WPC @ 3% or as per manufacturer instructions etc complete all as specifed and directed.
Dismantling of existing tarfelt from the roof and M&L priming plastered roof surfaces with bituminous primer @ 0.3 Kg/sqm as per IS-3384 and providing water proofing treatment by applying 3.5 Kg/sqm actatic poly propylene (advanced App torch membrane with fiber glass and finished on top over and including rendering 10mm thick in CM 1:4 on concrete surfaces of roofs parapet etc, finishing to surfaces even and smooth with out using extra cement and providing necessary slope incl using WPC @ 3% or as per manufacturer instructions etc complete all as specifed and directed.
M&L salt glazed stoneware drain pipes laid in trenches & jointed as specified of 150mm dia complete all as specified and directed by Engineer-in-Charge.
M&L Concrete bed to drain pipes of 150mm dia bore in PCC 1:3:6 type C-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested including conection to man hole complete all as specified and as directed
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L PCC in surface channels and drain type B2 (1:2:4) using 40mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed by Engineer in Charge
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M & L 75 mm thick PCC type D2, 1:4:8 (40mm graded aggregate) finished even and smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushion/bed for laying interlocking tiles / paver blocks complete all as specified and directed by Engineer-in-Charge.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with gery cement and no pigment, etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in copings around thepaver block for setting etc including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and as directed.
M&L for Light shade, Vitrified Ceramic coloured tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm (1200x600mm), in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed of CM 1:6 and pointed in white or coloured cement to match etc. including dismantling existing tiles complete all as specified and directed by Engineer-in-Charge.
Ditto all as per Item No. 108 above but on verticle surface as in skirting complete all as specified and directed by Engineer-in-Charge.
M&L for granite slab any type black colour 15-20mm thick machine cut, bedded and jointed with grey cement slurry over 15mm thick screed bed of CM 1:6 and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete as in shelves including rounding to edges of stone slabs complete all as specified and directed by Engineer-in-Charge.
S&F Towel Rack 600 mm long without lower hanger but with 3 hooks complete all as specified and directed by Engineer-in-Charge. Make : Jaguar Cat no:CAN-1181FHN or Its equivalent
S&F Corner glass shelf with railing of Make Jaguar Cat No: ACN1173 complete all as specified and directed by Engineer-in-Charge. Make : Jaguar Cat no:CAN-1181FHN or Its equivalent
S & F Wall hung WC with UF soft slose seat cover hinges Accessories ,Set Size 385x5695x385 mm complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat No:KUS-WHT-35951 OR its equivalent
S&F counter top basin of size 610x475x210mm(QUEENS) of complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No JCS WHT 7601 or its equivalent.
S&F towel rail 600 mm long with lower hanger QUEENS ccomplete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No AQN 77781or its equivalent
S&F Soap dish QUEENS complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No AQN 7731or its equivalent
S&F angular stop cock with flange (QUEENS) complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No AQN 70 53or its equivalent
S&F health faucet (ABS with 8 mm dia, 1.2 m long flexible tube and wall hook (allied) complete all as directed by Engr-in-Charge. Make: Jaguar Cat part No ALD-CHR-593N or its equivalent
S&F toilet paper holder (QUEENS) complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No AQN 7751 or its equivalent
S&F two way bib cock with wall flange (QUEENS) complete as directed by Engr-in-Charge. Make: Jaguar Cat part No QQT-7041 or its equivalent
S&F in central hole basin mixer with regular spout with popup waste system with 450mm long braided hoses (QUEENS)complete all as specified and directed by Engineer-in-Charge. Make: Jaguar Cat part No QQT-7169B or its equivalent
S&F in toilet paper holder (ABS Body) with 8 mmdia, 1.2 metre long flexible tube and wall hook (Allid) complete all as specified and directed by Engineer-in-Charge.
S&F looking mirror of size 1.50 m long and 0.90 mtr wide with fancy glass with decorative beading complete all as specified and directed by Engineer-in-Charge.
S&F in wall mixer with over head showerr arrangement connecting leg and wall flange but without crutch and telephonic shower with suitable connection and accesseries etccomplete all as specified and directed by Engineer-in-Charge. Make : Jaguar, Hindware, Cera
S&F over head shower with wall flange but without crutch and telephonic shower with suitable connection and accesseries etc complete all as specified and directed by Engineer-in-Charge. Make : Jaguar, Hindware, Cera
S&F 15 mm dia stop/ angle valve, chromium plated fancy type, cast copper alloy with capstain/ fancy type handle , screwed down , screwed both ends for iron pipe or for brass ferrule with wall flange complete all as specified and directed by Engineer-in-Charge. Make: Jaquar, cat part No- CON-059KN
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishescomplete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit wiring in walls/PVC conduit on wall including Tee, Junction boxes and modular boxes and modular cover plates of suitable size including suitable screws with washer for mounting modular switchs, modular sockets and modular regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly including cutting and chassing of wall complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP Note:- Wiring to be carried out in existing pipe in celing/roof.
All as per item No. 128 above but for One Ceiling Fan / exhaust fan point controlled by one, one modular switch and modular regulator
All as per item No.128 above but for One bell point controlled by one modular bell push switch
All as per item No. 128 above but for One 3 pin 5 Amps modular switch socket outlet point controlled by one switch on independent board .
All as per item No. 128 above but for One 3 point 5 Amps modular switch socket outlet point controlled by one modular switch on the same board.
All as per item No. 128 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps modular switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular Switch , flush type 5 Amps capacity 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Modular bell push 5 Amps, flush type one way complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Modular switch socket combination 2 in 1 multipurpose 5/15 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular electronic ceiling fan regulator 2M type heavy duty suitable to work on 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Bell ding dong, AC 230 Volts, SP complete all as specified and directed.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed by Engineer-in-Charge.
Material and labour for Concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring including cutting chassing of walls and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. Note:- Wiring to be carried out in existing pipe in celing/roof.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED energy efficient security light fitting of capacity of 35 W including suitable dia GI pipe bracket for fixing the light on wallcomplete all as specified and directed by Engineer-in-Charge. NOTE : quoted rate included the suitble GI pipe bracket,nuts and bolts.
Supply and fixing lamp holder insulated body with back plate for angle batten fitting fixed with round block including LED bulb 9/10 W non dimmable type complete all as specified and directed
Supply and fix sheet metal enclosure with double pole and Earth Metal Plug & Socket including 20A SP MCB complete all as directed by Engr in Charge. .
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm and connecting up with and including necessary 3 core PVC insulated copper flexible cord of size 23/0.019 from exhaust fan to the ceiling rose including making hole in the wall and making good edges in cement plaster complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc.complete all as specified and directed by Engineer-in-Charge.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 25 Sqmm , 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, spread sand of approval in cable trenches providing for cable cushioning complete all as specified and directed by Engineer-in-Charge. NOTE :- Punned thickness of sand only will be measured and paid.
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing the medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed
S & f in replace of Vertical type MCCB TPN DB 4 way double door made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 100 amps suitable for Vertical MCCB DB all as specified and directed .
Supply and fixing MCB double door DB SPN 8 way with 200 Amps busbar 240V all as specified and directed.
Supply and fixing MCB SPN 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB. complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced , 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.).
MAHALAKSHMI INFRA PROJECTS
VENKATA PRABHAVATHI CONSTRUCTIONS
M/S DIVIJA BUILDERS
SAI RUPA CONSTRUCTIONS
Neeru Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .