Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹59.4 LAccepted-AOC | ₹59.4 L | 1 | Accepted-AOC Work Order |
| 2 | 2₹60.6 L+₹1.2 L (2.00%)Rejected-Finance | ₹60.6 L+₹1.2 L (2.00%) | 2 | Rejected-Finance Reject |
| 3 | 2₹60.6 L+₹1.2 L (2.00%)Rejected-Finance PLOT NO 8 MATHURA NIWAS M KARANDWADI PO DEOGAON TALUKA JILHA SATARA PIN 415004 | SATARA | MAHARASHTRA | 415004 | ₹60.6 L+₹1.2 L (2.00%) | 2 | Rejected-Finance Reject |
| 4 | 3₹61.8 L+₹2.4 L (4.00%)Rejected-Finance | ₹61.8 L+₹2.4 L (4.00%) | 3 | Rejected-Finance Reject |
| 5 | Not Admitted-Fee/PreQual/Technical A P VADUJ TAL KHATAV DIST SATARA | SATARA | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹59.4 L
EMD Value
₹70,592
Closing Date
2 Jan 2026, 5:00 pmClosed
Additional Chief Executive Officer Z P Satara
Additional Chief Executive Officer Z P Satara
CONSTRUCTION OF FIVE ROOM SCHOOL BUILDING AT ALJAPUR TAL PHALTAN
2025_SATAR_1263279_1
Works/North/A-8/Shala/08/25-26
Open Tender
Civil Works
Percentage
300 days
CONSTRUCTION OF FIVE ROOM SCHOOL BUILDING AT ALJAP
open
8 documents required · 8 mandatory
₹5,000
₹70,592
11 Jul 2026
26 Dec 2025
5 Jan 2026
26 Dec 2025
2 Jan 2026
26 Dec 2025
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 2 / 153 Specification No : Bd.A.1 Spec. Page No : 259 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 6 / 153 Specification No : Bd.A.2 Spec. Page No : 259 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. Item / Page No : 38 / 157 Specification No : Bd.A.12 Spec. Page No : 264
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : As per Item No 6a Spec. Page No : --- Additional Specifications : As per Item No 6a
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete plinth beams as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (using ARTIFICIAL SAND). Item / Page No : 23A / 185 Specification No : Bd.F.12, B-7 Spec. Page No : 304-305, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Item / Page No : 36 / 157 Specification No : Bd.A.10 Spec. Page No : 262-263
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : As per Item No 11a Spec. Page No : --- Additional Specifications : As per Item No 11a
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : As per Item No 12a Spec. Page No : --- Additional Specifications : As per Item No 12a
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : As per Item No 13a Spec. Page No : --- Additional Specifications : As per Item No 13a
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 185 Specification No : Bd.F.13 Spec. Page No : 305 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306 Additional Specifications : 1. Steel to be used must be as per Indian Standard : 1786 (1985) with latest amendments and manufactured by approved and reputed make. 2. Steel to be used must be procured directly from the manufacturers or from authorised agent of main producers. 3. Various diameters of TMT-FE-500 steel bars brought on site of the work shall be got tested category wise and lot wise, as directed by the Engineer In-Charge and minimum 50 percent of testing should be done in the departmental laboratory.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor) Item / Page No : 33 / 188 Specification No : As per Item No 15a Spec. Page No : --- Additional Specifications : As per Item No 15a
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 16a Spec. Page No : --- Additional Specifications : As per Item No 16a
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Specification No : As per Item No 17a Spec. Page No : --- Additional Specifications : As per Item No 17a
Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For Ground Floor) Item / Page No : 10 / 246 Specification No : Bd.T.36 Spec. Page No : 500 Additional Specifications : Door shutter and fixtures and fastenings shall be got approved by Engineer in-charge.
Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For First Floor) Item / Page No : 10 / 246 Specification No : As per Item No 18a Spec. Page No : --- Additional Specifications : As per Item No 18a
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 2 / 264 Specification No : Bd.U.1 Spec. Page No : 537 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The grill design shall be got approved from the Engineer in-charge before use.
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) Item / Page No : 2 / 264 Specification No : As per Item No 19a Spec. Page No : --- Additional Specifications : As per Item No 19a
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor) Item / Page No : 44 / 254 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For First Floor) Item / Page No : 44 / 254 Specification No : As per Item No 20a Spec. Page No : --- Additional Specifications : As per Item No 20a
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For Ground Floor) Item / Page No : 27 / 210 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For First Floor) Item / Page No : 27 / 210 Specification No : As per Item No 21a Spec. Page No : --- Additional Specifications : As per Item No 21a
Providing and fixing in position powder coated aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastening such as 5 milimetre thick clear float glass, excetra complete. (For Ground Floor) Item / Page No : 53b / 257 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. Weight of aluminium section must be 6.90 kilogram per square metre.
Providing and fixing in position powder coated aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastening such as 5 milimetre thick clear float glass, excetra complete. (For First Floor) Item / Page No : 53b / 257 Specification No : As per Item No 22a Spec. Page No : --- Additional Specifications : As per Item No 22a
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : Bd.L.2, Bd.L.10 Spec. Page No : 368, 370 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : As per Item No 23a Spec. Page No : --- Additional Specifications : As per Item No 23a
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : As per Item No 24a Spec. Page No : --- Additional Specifications : As per Item No 24a
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor) Item / Page No : 4 / 173 Specification No : Bd.C.8 Spec. Page No : 278
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For First Floor) Item / Page No : 4 / 173 Specification No : As per Item No 25a Spec. Page No : --- Additional Specifications : As per Item No 25a
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : As per Item No 26a Spec. Page No : --- Additional Specifications : As per Item No 26a
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : As per Item No 27a Spec. Page No : --- Additional Specifications : As per Item No 27a
Providing 25 milimetre to 30 milimetre thick partition of polished black Kadappa stone slab of approved quality including giving required sizes and shape, excetra, fixing in cement mortar 1:3, curing and cement, excetra complete. - One side polish (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 32 / 216 Specification No : Bd.M.35B Spec. Page No : 393 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : Bd.M.22 B Spec. Page No : 390 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. The edge of step should be chafered or rounded as directed. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : As per Item No 29a Spec. Page No : --- Additional Specifications : As per Item No 29a
Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Item / Page No : 55 / 280 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The specified diametre of the pipe shall refer to the inside diametre of the pipe and fittings. 3. Screw clips and fittings shall be of standard type to match the pipe.
Providing and fixing white glazed earthenware wash hand basin of 55 centimetre X 40 centimetre size including cold water piller tap / cold and hot water piller tap brackts, rubber plugs and brass chain, stop tap and necessary pipe connections including polyvinyl chloride waste pipe and trap upto the outside face of the wall.Making good the damaged surface,testing excetra complete. (For Ground Floor) Item / Page No : 63 / 272 Specification No : Bd.V.30 Spec. Page No : 565
Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For Ground Floor) Item / Page No : 67 / 281 Specification No : Bd.V.32A Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing, laying and fixing polyvinyl chloride pipe of 75 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra inclduding necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 27 / 276 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick bats. Item / Page No : 19 / 275 Specification No : Bd.V.46 Spec. Page No : 576
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor) Item / Page No : 54 / 280 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface (excluding the primer coat), excetra complete. (For Ground Floor) Item / Page No : 12 / 227 Specification No : Bd.P.6 Spec. Page No : 414 Additional Specifications : 1. The priming coat should be applied and got approved from Engineer in-charge. 2. The shade of paints shall be got approved by the Engineer in-charge before use. 3. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use. The work shall be carried out as per instructions of Engineer in charge.
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface (excluding the primer coat), excetra complete. (For First Floor) Item / Page No : 12 / 227 Specification No : As per Item No 36a Spec. Page No : --- Additional Specifications : As per Item No 36a
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 25 / 225 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For First Floor) Item / Page No : 25 / 225 Specification No : As per Item No 37a Spec. Page No : --- Additional Specifications : As per Item No 37a
Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table survey with the help of 24" Alidade. The dolomite area measurement of the plot and structures, trees, over head line and under ground service amenities within the area, with triagular method and giving detailes of the structures, such as total area, type of building and distance from all corners, taking trial pit 0.5 metre X 0.5 metre X 2.00 metre 2 numbers per acre and collection of record from city survey / D.I.L.R. authorities and authentication. The plan shall be traced on 75 micron polyster film and shall be submitted along with three amonia prints. The contour levels shall be marked at 0.5. metre intervals. - above 1 Acre. Item / Page No : 23 / 15 Additional Specifications : The Work shall be carried out as per the instructions of Engineer In-Charg.
Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. Item / Page No : 12 / 294 Specification No : Bd.W.7 Spec. Page No : 586-587
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For First Floor) Item / Page No : 34 / 236 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 1 / 205 Specification No : Bd.J.2 Spec. Page No : 355 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand 1 Test per Source
Compressive Strength of Cement Concrete Cube 1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre
Sieve Analysis Test for Metal below 40 milimetre 1 Test per 200.00 Cubic Metre
Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre 1 Test per Source
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks 1 Test per 50000.00 Number
Compressive Strength of Cement Mortar 1 Test per Day
Liquid Limit & Plastic Limit for Plinth Filling 1 Test per 1000.00 Cubic Metre
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.77 MB
b1.pdf
Tender Documents • 5.73 MB
BOQ_2176868.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .