Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹36.8 LAdmitted-Finance | -21.51% | ₹36.8 L | L1 | Admitted-Finance |
| 2 | L2₹40.7 LAdmitted-Finance | -13.12% | ₹40.7 L | L2 | Admitted-Finance |
| 3 | L3₹46.3 LAdmitted-Finance | -1.20% | ₹46.3 L | L3 | Admitted-Finance |
| 4 | L4₹46.6 LAdmitted-Finance | -0.50% | ₹46.6 L | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹46.9 L
EMD Value
₹93,760
Closing Date
9 Jan 2026, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2025_PWDJK_299464_1
e-NIT No.EDJ/169 of 2025-2026 Dated 30-12-2025
Open Tender
Electrical Works
Rajouri
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹93,760
21 Feb 2026
30 Dec 2025
10 Jan 2026
31 Dec 2025
9 Jan 2026
31 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 x 10 sq. mm + 2 x 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"curve including connections, painting etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
6 way ( 4+18), (Double door) (TPN type)
8 way (4 + 24), Double door (TPN Type)
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
Single pole 6/10/16/32 Amp
Single pole and neutral 40 Amp
Triple Pole and netural upto 32 amp.
Triple pole and neutral 40 Amp
Supplying & fixing of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F >.90
Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long (3 Star)
Exhaust fan 300 mm size (Metalic)
Supplying, installation, Testing & Commissioning of 72 watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
100 Amp, 30 KA, FP MCCB ICU = 100% ICS
250 Amp, 36KA, FP MCCB ICU = 100% ICS
ON Load Change Over Switch FP 100 amp. (Front operated)
Aluminium Bus Bar 400 Amp set of 4 strips 18"
Aluminium Bus Bar 200 Amp set of 4 strips 18"
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 185 sq. mm 3.5 core
Supply, Installation, Testing & Commissioning of IP Dome Camera -Video Standard PAL/NTSC,Image Sensor 1/2.8” CMOS,Number Of Pixels (H × V) 1920(H) × 1080(V),Minimum Illumination 0.0035 [email protected], AGC ON 0 lux with IR ON,S/N Ratio > 50 dB,Electronic Shutter Speed 1s ~ 1/ 100,000s,IR Distance Up to 30 m, Day/Night Auto (ICR)/Day /Night/Timing ,Backlight Compensation BLC, HLC White Balance Auto/Indoor /Outdoor/ Manual,Wide Dynamic Range Digital WDR,Noise Reduction 3D DNR,Privacy Masking Off / On (4 Areas),Motion Detection Support,Region Of Interest Support (3),Lens 2.8 mm, Fixed Angle Of View H: 105.4°, V: 72.9°,Audio One way, Inbuilt Microphone,Video Compression Resolution H.265 / H.264,Frame Rate Bit Rate Control CBR / VBR Bit Rate 64 Kbps ~ 6 Mbps 1080P(1920×1080), 720P(1280×720), D1(704×576), CIF(352×288), 480×240 Main stream: 1080P/720P (1~25/30fps) Sub stream: D1/CIF (1~25/30fps) Third stream: D1/CIF/480x240 (1~25/30fps),Interoperability ONVIF Profile S, G Maximum Users Access 3 Users Protocols* IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP, IGMP, SMTP, DHCP, NTP, DNS, DDNS, QoS, 802.1X, UDP, ICMP, ARP, TLS Security User account and password protection, HTTPS, IP Filter, TLS1.2, AES-128 ,Micro SD Micro SD/SDHC/SDXC card slot (128GB),Operating Temperature,Certification CE, FCC, RoHS -30°C ~ 60°C (-22°F ~ 140°F),Ingress Protection IP67
Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Video Recorder) Embadded Linux based for recording upto 16CH @ D1 with 02 nos. SATA HDDs minimum 20TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Control Pannel with LEDs Indication, 2 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidance Clip Export to USB, 16 Channel Syncronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Softawre, iPhone; iPad; Android based Mobile clients, 01HDMI & 01VGA Output, 02 On Board HDDS each up to 10TB, Alarm Input (1 nos.), Alarm Output (01 nos.), NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA, CE, FCC, EN, NDAA & RoHS compliant.including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. Make BOSCH/AXIS/Pelco/Honey well series 35
Supply, Installation, Testing and comissioning of 8 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt.
Supply Installation Testing and Commissioning of Enterprise Surveillance HDD of 6TB .
Supply Installation Testing and Commissioning of Category 6 RJ-45 Connector.
Supply Installation Testing and Commissioning of Category 6 UTP Patch Panel Blank Punch Down 24 Port.
Supply Installation Testing and Commissioning of 43" Screen FHD Industrial Grade 24/7 operation display with HDMI and HDMI cable.
Supplying and fixing of following sizes of 25 MM PVC conduit(Medium Duty ISI) along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-.
Supply Installation Testing and Commisioning of 3X 2.5 sqmm FRLS Power Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply Installation Testing and Commisioning of 4K Hdmi Cable with all accessories as required with length of 5 Mtr.
SITC of MCB tupe Single Phase Surge Protection Devices 40 KA
CAMC for CCTV 02 years after Defect liability period of 01 year
Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure)
Supplying, installation, testing and commissioning of 150/150 Liters of water Cooler having full stainless steel body, cooling capacity 150 ltr/hour and storage capacity 150 ltr alongwith PVC connecting pipes as required. (ISO Certified) .
Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.
(RO + UV + UF mineral control with TDS control )
UV purifier for water cooler
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Design, manufacture and supply of outdoor type of three phase 415 volt LT unbalanced 200 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 160 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load . PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 2 Years after DLP of 1 Year.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_971486.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid