Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹13.0 LAdmitted-Finance | -17.21% | ₹13.0 L | L1 | Admitted-Finance |
| 2 | L2₹13.2 LAdmitted-Finance | -15.87% | ₹13.2 L | L2 | Admitted-Finance |
| 3 | L3₹15.0 LAdmitted-Finance | -4.11% | ₹15.0 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹15.7 L
EMD Value
₹31,380
Closing Date
18 Feb 2026, 6:00 pmClosed
ADPC, SMSA HANUMANGARH
OFFICE OF THE ADPC, SMSA HANUMANGARH
Construction of ACR-2 with Corri. under MLA LAD
2026_RCSCE_536864_1
Enivida/2025-26/HMH/MLALAD
Open Tender
Civil Works
180 days
NOHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
ADPC ,SMSA, MD, RISL
₹31,380
26 Feb 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
PART A CIVIL WORK
E.W In Excavation In Foundation Trenches Or Drains Including Dressing Of Sides & Ramming Of Bottoms, Lift Upto 1.50 Mtr Including Taking Out The Excavated Soil And Depositing & Refilling Of Jhiri With Watering & Ramming & Disposal Of Surplus Excavated Soil as Directed within a lead of 50 m. all kind of soil
P&L Cement Concrete Including Curing, Compaction Etc. Complete Using stone Aggregate 40mm Nominal Size In Floring & Foundation Excluding The Cost Of Shuttering Using 1 Cement:4 Sand:8 Aggregate Mix.
Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 in foundation and plinth with CM 1:6
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level.
Providine And Laying In Position specified grade ofreinforcement Cement Concrete Including Curing, Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttring Upto Plinth Level In 1:1.5:3 (1 Cem. :1.5 Coar. Sand : 3 Graded Stone Aggr. 20mm Non. Size)
Supply & Stacking good earth at site complete including loading unloading & transporation etc. Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidating each deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr.
Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 in Super structure with CM 1:6
Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 in Super structure with CM 1:4
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for:Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.Thermo-mechanically Treated bars
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing And Fixing Steel Glazed Doors Windows And Ventilator With Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x13 Mm, 10 Cm. Long Embedded In Cement Concrete Block 15x10x10 Cm Of 1:3:6 (1 Cement:3 Course Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screw Or Rawl Plungs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing Adn Fixing Of Plain Glass Panes 4 Mm Thick With Coper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including The Cost Of Metal Beading And Other Fitting Except Necessary Hings Of Pivots Steel Handles Peg Stay Etc. As Required As Per Is:1038
P&F M.S. Sheet Double Leaf Door Shutter In Angle Iron Frame 35 x35 x 5mm Suitability Diagonally Braced With 25*3mm Flat Iron Above And Below Lock Rail Of Size 50 x 5mm Beading Extra Including All Fittings As Per Direction Of Chokhats But Excluding Cost Of Chowkhats 18 SWG MS Sheet
P&F Guard Bars For Windows & Bottom Of Doors Frame.
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 mmx 50 mm x 2.1 mm
6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand)
Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished. 12mm Thick
External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished. 20 mm thick
Making grooves as per design in plaster 10mm to 20mm wide
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size 2001 to 5000 Sq.Cm
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2000 Sqcm
Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls (any thickness) including attached pilasters, coloumns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, plain window sills, fillets etc up to floor three level excluding the const centering and shuttering.
Roof Grading :- Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size).
Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.
Making khurras 450 x 450mm with averageminimum thickness 50 mm cement concrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40 micron finished with 12 mm cement plaster 1:3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)
Interior Finishing :- Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: New work(Two or more coats) including prepartion of base with primer, putty, lippy etc complete in all respect.
Exterior Finishing :- Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect. including scaffolding and safety provision On New work
Painting With Enamel Paint Of Approved Brand & Manufacture To Give An Even Shade. New Work ( Two Or More Coats).
PART B SANITARY WORK
P&F rigid 110 mm dia pvc pipe class IInd (4kg./cm2) approved quality make including jointing the pipe with solvent cement rubber rim & lubricant .
PART C ELECTRIC WORK
Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Long point (up to 10 mtr..)
Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modular switch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply & drawing Wiring for sub mains as per PWD specification for electrical Works with ISI marked (IS:694) , 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped including all as per pre approved by Engineer in charge, making connections, as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per 4' LED Tube shape fixture 18/20 W (Polycarbonate Base)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.93 MB
Tendernotice_2.pdf
PDF • 3.78 MB
BOQ_956767.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid