Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 59 SIDCO INDUSTRIAL ESTATE NALLAMANAICKENPATTI POST SIDCO INDUSTRIAL ESTATE VIRUDHUNAGAR TAMIL NADU 626102 | VIRUDHUNAGAR | TAMIL NADU | 626102 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 150 VILLARASAMPATIBALL ROAD PO NASIYANUR ROAD ERODE 638107 TAMIL NADU | ERODE | ERODE | TAMIL NADU | 638107 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 56 ARUNACHALAM MAIN ROAD AMBAL NAGAR PORUR CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
4 Oct 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Hydro
The Chief Engineer/ Hydro, TANGEDCO Ltd., 5th Floor, NPKRR Maaligai, 144, Anna Salai, Chennai-600 002.
Rectification and replacement including Re-insulation of defective stator coils (Top and Bottom) in Y Phases including supervision, erection, testing and Commissioning of 100 MW Generator of Unit III of KADAMPARAI Power House in Kadamparai Generation
2021_EB_210840_1
HE2410
Open Tender
Electrical Works
Works
30 days
Kadamparai
As per the BQR in spec HE2410
4 documents required · 4 mandatory
₹0
₹45,000
Yes
5 Oct 2021
23 Sept 2021
5 Oct 2021
23 Sept 2021
4 Oct 2021
24 Sept 2021
180 days
Amount
Charges towards de-soldering both the pole jumpers, removing the ‘ V ‘ block and damper coils series link.
Charges towards removing the 8 Nos. static key and 8 Nos. sliding key per pole with special jigs and hydraulic jacks.
Charges towards lifting of 4 Nos. rotor poles after ensuring all connections are disconnected and by using suitable lifting device.
Charges towards removing the top coils by de-wedging and removing the overhang bandings with special jigs and fixtures.
Charges towards removing the bottom coils by de-wedging and removing the overhang bandings with special jigs and fixtures.
Charges towards making of continuity of other coils in the circuit, testing the whole Generator to ascertain the healthiness of other coils before execution of works. i) IR value at 5 KV megger before and after HV AC test. ii) HV AC as per instruction of field engineers. iii) PI value at 5 KV megger.
Charges towards removing the old failed insulation and re-insulating with Class F insulation on both sides of overhang portion of the released top coils (slot areas) and testing the top coils. The following tests are to be carried out : i) IR value at 5 KV before HVAC test ii) HVAC test at 18 KV iii) IR value at 5 KV after HVAC test
Charges towards installing the spare / re-insulated tested bottom coils with Class F insulation (Spare coils shall be supplied by TANGEDCO) with using fresh liners, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin.
Charges towards installing the spare / re-insulated tested top coils with Class F insulation (Spare coils shall be supplied by TANGEDCO) with using fresh liners, wedges, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin.
Charges for Re-soldering the non-connection and connection side end ferrules and jumpers and insulating the all joints
Charges for re-positioning the pole in the rotor spider, locking the keys, fixing the ’V’ blocks with suitable insulation.
Charges for making end connection, locking the jumpers and connection links with suitable insulated locks, soldering the end connection.
Charges for cleaning of stator and rotor windings and drying out.
Charges for following test on stator and rotor: Stator: i) IR value at 5 KV megger before and after HV AC test. ii) HV AC as per instruction of field engineers iii) PI value at 5 KV megger. iv) PI value v) Winding resistance vi) Tan Delta at 11 KV in the steps of 0.2VL, 0.4VL, 0.6VL, 0.8VL and 1.0 VL. Rotor: i) IR value at 500 V ii) Winding resistance iii) Surge test at 1 KV iv) AC Drop test and commissioning of machine.
CGST in % (For Bidders inside TamilNadu)
SGST in % (For Bidders inside TamilNadu)
IGST in % (For Bidders outside TamilNadu)
ATHI ELECTRIX COMPANY
Coral rewinding India Private Limited
SHREE ABIRAMI ENGGINEERING WORKS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .