| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 CrAccepted-AOC B 437 438 ROAD NO 18A KALADWAS BHAMASHAH INDUSTRIAL AREA UDAIPUR RAJASTHAN 313001 | UDAIPUR | RAJASTHAN | 313001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.0 Cr+₹68.3 L (2.93%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical 201 202 LALA 1 LANDMARK MG ROAD HYDERABAD HYDERABAD | - | Rejected-Technical Technically not responsive | |
| 4 | Not Admitted-Fee/PreQual/Technical 603 QUANTUM TOWER 6TH FLOOR RAMBAUG LANE S V ROAD MALAD WEST MUMBAI 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹24 Cr
EMD Value
₹48 L
Closing Date
27 Jan 2022, 3:00 pmClosed
MD, RISL
yojana bhawan
Request for Proposal (RFP) for Interior Work of RCAT at Suchna Kendra, Jaipur
2022_RISL_253480_1
F3.3(355)/RISL/PUR/2021/5754
Open Tender
Miscellaneous Works
Item Rate
150 days
work
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
MD, RISL
₹48 L
Yes
8 Apr 2022
6 Jan 2022
27 Jan 2022
6 Jan 2022
27 Jan 2022
6 Jan 2022
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Acoustic Metal Paneling
1) Factory-made removable type self-inter-lockable metal panels with a front sheet of preformed textured hot-dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating at least 0.11mm). The back cover of the panel shall be made up of a 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of a specially designed combination of perforated and non-perforated panels through CNC laser cutting, bending & punching. The panelling/partition shall be Greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. The necessary certificate / test report valid on the bid date and to be submitted along within seven days from the date of purchase order. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on the structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm.
2) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the office interior it is necessary that the at-least twenty-five per cent of the wall panelling tiles have micro-perforations (less than 1.6mm dia. each) all over the surface with a density of 5000 holes per square feet. This feature shall be audit certified (from UL/Intertek/NABL/ reputed test laboratory) on modular wall panelling tile to have clean perforations and provide a smooth finish on the front fascia of tiles. The tile shall have 5000 holes per square foot on the front side of the tile.
3) To provide an acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and the partition should be 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part IV- 1984, ISO: 140(Part III) -1995, as per the test report from UL / Intertek / NABL/ reputed test laboratory.
4) Seismic safety of users & equipment is a prime concern area. The metal panelling/partition must sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations. The test must be carried out by an authorized agency i.e., from UL / Intertek / NABL / reputed test laboratory.
5) The wall panelling should be robust & strong enough to sustain the routine loads/minor impacts of a typical office environment. The wall panelling/partition structure shall have audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of Load-bearing capacity of 300 Kgs to hold any display unit on clamp having a minimum length of 750mm.
6) Audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of modular wall panelling tile having secure locking arrangement for equidistant mounting. Locking arrangement enables easy replacement without using any tool within 20 seconds. The feature shall provide easy flexibility of locking all tiles in one column through gravity. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid.
7) The modular metal panelling must comply to the lead-free directive to ensure the restriction of hazardous substances so that the final product does not contaminate the environment. The final product i.e., modular metal panelling does not contain hazardous substances and we give a healthy life to our coming generations it is necessary that the modular metal panelling system shall be RoHS certified (from UL / Intertek / NABL / reputed test laboratory).
8) From a fire safety point of view, the metal wall panelling tiles shall be class A fire rated as per the norms of comparative measurements of surface flame spread and smoke density measurements with that of select grade red oak and fibre-cement board surfaces under the specific fire exposure conditions. The proposed wall panelling tiles shall be Class A certified as per ASTM e84 (from UL / Intertek / NABL / reputed test laboratory) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 100 | - |
| 2 | SITC of Acoustic Metal Partition
1) The material of construction and technical specification shall remain the same as per acoustic metal panelling (Sr No. 1 acoustic metal panelling) however in partition the cladding shall be done on both sides of the section/grid work.
2) Factory-made removable type self-inter-lockable metal panels with a front sheet of preformed textured hot-dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating at least 0.11mm). The back cover of the panel shall be made up of a 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of a specially designed combination of perforated and non-perforated panels through CNC laser cutting, bending & punching. The panelling/partition shall be Greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. The necessary certificate / test report valid on the bid date and to be submitted along within seven days from the date of purchase order. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on the structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm.
3) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the office interior it is necessary that the at-least twenty-five per cent of the wall panelling tiles have micro-perforations (less than 1.6mm dia. each) all over the surface with a density of 5000 holes per square feet. This feature shall be audit certified (from UL/Intertek/NABL/ reputed test laboratory) on modular wall panelling tile to have clean perforations and provide a smooth finish on the front fascia of tiles. The tile shall have 5000 holes per square foot on the front side of the tile.
4) To provide an acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and the partition should be 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part IV- 1984, ISO: 140(Part III) -1995, as per the test report from UL / Intertek / NABL/ reputed test laboratory.
5) Seismic safety of users & equipment is a prime concern area. The metal panelling/partition must sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations. The test must be carried out by an authorized agency i.e., from UL / Intertek / NABL / reputed test laboratory.
6) The wall panelling should be robust & strong enough to sustain the routine loads/minor impacts of a typical office environment. The wall panelling/partition structure shall have audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of Load-bearing capacity of 300 Kgs to hold any display unit on clamp having a minimum length of 750mm.
7) Audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of modular wall panelling tile having secure locking arrangement for equidistant mounting. Locking arrangement enables easy replacement without using any tool within 20 seconds. The feature shall provide easy flexibility of locking all tiles in one column through gravity. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid.
8) The modular metal panelling must comply to the lead-free directive to ensure the restriction of hazardous substances so that the final product does not contaminate the environment. The final product i.e., modular metal panelling does not contain hazardous substances and we give a healthy life to our coming generations it is necessary that the modular metal panelling system shall be RoHS certified (from UL / Intertek / NABL / reputed test laboratory).
9) From a fire safety point of view, the metal wall panelling tiles shall be class A fire rated as per the norms of comparative measurements of surface flame spread and smoke density measurements with that of select grade red oak and fibre-cement board surfaces under the specific fire exposure conditions. The proposed wall panelling tiles shall be Class A certified as per ASTM e84 (from UL / Intertek / NABL / reputed test laboratory) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 100 | - |
| 3 | SITC of Printed Panelling
1) The printed panelling shall have the same technical specifications as that of acoustic metal panelling (Wall Finishing - Sr No. 1 acoustic metal panelling). However, in addition to it, the front tile shall be digitally printed. Graphics shall be approved by the Customer.
2) Digital printing shall be done on modular metal Panelling. Pasting stickers/flex/vinyl on metal tile shall be deemed unacceptable.
3) The structure shall be made from a modular, heavy-duty powder-coated CRCA frame (minimum sheet thickness 1mm) and shall allow an uninterrupted flow of wires/cable/tubes of maximum diameter 25mm.
4) The structure shall be securely connected from the wall, roof and floor. It shall be made up of a minimum of 1mm thick vertical slotted rolled C sections (Upright) and horizontal rolled ‘C’ connectors. Grid of the desired dimension shall be formed by Vertical and horizontal sections having 20 to 50mm pitch.
5) For Structure: - Powder coated CRCA steel sheet. (Sheet thickness minimum 1.0mm with powder coating).
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 4 | SITC of designer metal panelling with images
The metal panelling shall have the same technical specifications as that of acoustic metal panelling (Wall Finishing - Sr No. 1 acoustic metal panelling). However, in addition to it, it shall have images printed on vinyl.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 5 | SITC of designer metal panelling with vertical louvers
Metal vertical louvers are made up of metal C sections. The overall louver size shall be of minimum 50 X 80 mm. The sheet thickness shall be a minimum 0.6mm. Copy of Test certification/report for ASTM E84 (from UL / Intertek / NABL / reputed test laboratory) for the surface burning characteristics of wall Panelling tiles. This is a mandatory requirement from a Fire safety point of view.The structure shall be made up of a powder-coated CRCA steel sheet (sheet thickness minimum 1.6mm). The powder coating thickness shall be 60 to 90 microns. Metal panelling shall have the same technical specifications as that of acoustic metal panelling (Wall Finishing - Sr No. 1 acoustic metal panelling).
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 6 | SITC of modular fabric panelling
Flat fabric panelling made up of a minimum 600mm wide by minimum 300mm high tiles fitted as per the acoustical requirement. Fabric Make: Camira (Sprint) / Sunbury / Kvadrat / Response. The fabric tile shall have a similar structure (Wall Finishing - Sr No. 1 acoustic metal panelling) as that of modular metal panelling to ensure proper interchangeability with other rigid PVC metal cladding tiles.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 7 | SITC of modular fabric partition
Flat fabric partition made up of a minimum 600mm wide by minimum 300mm high tiles fitted as per the acoustical requirement. Fabric Make: Camira (Sprint) / Sunbury / Kvadrat / Response. The fabric tile shall have a similar structure (Wall Finishing - Sr No. 1 acosutic metal panelling) as that of modular metal panelling to ensure proper interchangeability with other rigid PVC metal cladding tiles. However in partition the cladding shall be done on both sides of the section/grid work.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 8 | SITC of printed lacquered glass panelling
1) Lacquered glass shall be of top quality clear toughened or ultra-clear toughened glass, to achieve the desired perfect shade. The Thickness of Lacquered Glass should be 8mm. It shall be the aesthetic appeal with Printing.
2) Features: -
2.1) Superior finish.
2.2) Modern and trendy aesthetic appeal.
2.3) Special lacquer for high durability and opacity, 7 times stronger than the normal conventional paints.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 9 | SITC of designer calcium cladding with printed lacquered glass
1) Plain Calcium Silicate Acoustic Boards for false ceiling with 08mm Approx. thick, Structure for the underside of the suspended grid formed of GI perimeter channels. Wood screws and metal expansion raw plugs for fixing with the wall. Plastic emulsion paint of approved make and shade for finishing the surface of Calcium Silicate Boards.
2) General Specification of Calcium Silicate Board: this board is manufactured from a mixture of Portland cement, fine silica, special cellulose fibres and selected fillers to impart durability, toughness, fire and moisture resistance
3) Specifications shall remain the same as that of normal lacquered glass 8 mm thick. The only difference shall be the aesthetic appeal with Printing as shown above.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
| 10 | SITC of straight glass partition material
1) Full height glass partitions walls shall be made of 12mm toughened glass with a frame-less structure. A proper structure shall be made to ensure the fixing of glass from the RCC slab above the false ceiling and holding channels on flooring.
2) Straight and vertical structural members shall not be visible. Glass shall be fitted on extrusion with tool-less technology and have a provision for replacing the glass with perforated sheet/acoustic tile by removing the glass.
3) NOTE: - The nature of installation shall be replaceable, expandable and flexible to cater for the future expansion/technical up-gradation.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP | - | Sq. Mtr. | 10 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_451900.xls
BOQ Document • 0.69 MB
90381297.pdf
Tender Document • 1.14 MB
RFP.pdf
Tender Document • 6.48 MB
90381299.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .