Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 CrAdmitted-Finance | ₹10.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹10.6 CrAdmitted-Finance | ₹10.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹10.8 CrAdmitted-Finance | ₹10.8 Cr | L3 | Admitted-Finance |
| 4 | L4₹11.0 CrAdmitted-Finance 17 JAIN NAGAR TALAB TILLO JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹11.0 Cr | L4 | Admitted-Finance |
| 5 | L5₹11.0 CrAdmitted-Finance | ₹11.0 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sumit Gupta L3 | AVG Contracts and Supplies pvt ltd L4 | SHARAT PURI CONTRACTORS L1 | FALCON ENGINEERING PROJECTS PRIVATE LIMITED L6 | MOHD SALEEM L5 | MOHD IDRIS SHAN L2 | KAPAHI CONTRACTS PRIVATE LIMITED L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m | ||||||||||
| 1.10 | All kinds of soil. | 2,654.39 | cum | 133 ₹3.5 L | 450 ₹11.9 L | 125 ₹3.3 L | 200 ₹5.3 L | 180 ₹4.8 L | 200 ₹5.3 L | 300 ₹8.0 L |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m | 1,592.63 | Cum | 133 ₹2.1 L | 500 ₹8.0 L | 125 ₹2.0 L | 115 ₹1.8 L | 100 ₹1.6 L | 100 ₹1.6 L | 200 ₹3.2 L |
| 3.00 | Providing and laying stone soling (hard stone/rubble of specified thickness) including hand packing and thoroughly filling the interstices/voids with coarse sand/moorum/stone chips, watering and compacting including consolidation with power roller/rammers, and all operations, complete as specified and directed by the Engineer-in-Charge. | 340.07 | cum | 933 ₹3.2 L | 2,000 ₹6.8 L | 1,270 ₹4.3 L | 750 ₹2.6 L | 800 ₹2.7 L | 1,150 ₹3.9 L | 1,000 ₹3.4 L |
| 4.00Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : | ||||||||||
| 4.10 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 492.8 | cum | 3,333 ₹16.4 L | 2,300 ₹11.3 L | 3,354 ₹16.5 L | 3,000 ₹14.8 L | 2,800 ₹13.8 L | 2,600 ₹12.8 L | 3,500 ₹17.2 L |
| 4.20 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 344.52 | cum | 3,933 ₹13.5 L | 4,000 ₹13.8 L | 4,300 ₹14.8 L | 4,200 ₹14.5 L | 4,000 ₹13.8 L | 3,050 ₹10.5 L | 4,500 ₹15.5 L |
| 4.30 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 8.28 | cum | 8,433 ₹69,825.24 | 6,200 ₹51,336 | 5,150 ₹42,642 | 6,400 ₹52,992 | 6,500 ₹53,820 | 4,100 ₹33,948 | 6,000 ₹49,680 |
| 5.00Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. | ||||||||||
| 5.10 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 3.26 | cum | 8,433 ₹27,491.58 | 6,200 ₹20,212 | 6,000 ₹19,560 | 7,000 ₹22,820 | 7,000 ₹22,820 | 2,000 ₹6,520 | 6,000 ₹19,560 |
Updated dates
Tender Value
₹14.3 Cr
EMD Value
₹28.7 L
Closing Date
12 Jan 2026, 4:00 pmClosed
Estates Officer, SKUAST-Jammu
Estates Division, SKUAST-J, Main Campus, Chatha
Construction of Faculty building with common facilities alongwith associated sanitary fittings and internal electrification at Main Campus Chatha, SKUASTJammu
2025_SKUST_298456_3
AU/Estates/2025-26/21 dated 16-12-2025
Open Tender
Civil Works
720 days
Main Campus, Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹3,000
Assistant Comptroller (Estates), SKUAST-Jammu
₹28.7 L
23 Jan 2026
18 Dec 2025
14 Jan 2026
18 Dec 2025
12 Jan 2026
18 Dec 2025
Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m
Providing and laying stone soling (hard stone/rubble of specified thickness) including hand packing and thoroughly filling the interstices/voids with coarse sand/moorum/stone chips, watering and compacting including consolidation with power roller/rammers, and all operations, complete as specified and directed by the Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, walls, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Columns, Pillars, Piers, Abutments, Posts and Struts.
Suspended floors, roofs, landings, balconies and access platform.
Stairs (excluding landings) except spiral staircases.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
Cold twisted/TMT bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :
Cement mortar 1: 4 (1 cement: 4 coarse sand)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer,
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Hot finished welded type tubes
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing of 18 mm thick, commercial grade, Prelaminated Plywood panels (BWR/BWP Grade) for bench seating and tabletops, complete with heavy-duty edge protection, conforming to all relevant IS standards.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete :
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete :
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Ordinary cement without any pigment.
Providing and laying Vitrified floor tiles (600x600 mm) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades laid over 20 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
Size of tile 600x600 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing precoated galvanized iron sheet 0.50 mm total coated thickness with zinc coated 120 grams per sqm as per steel grade, 5-7 epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns miniumum to aviod scrateches during transportation and should be supplied in single length upto 12 meter or as desired by Engineer_in-charge. The sheet shall be fixed using self driling with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete
Ridges plain (500 - 600mm)
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1:6 (1 cement: 6 fine sand)
12 mm cement plaster of mix : (Inside)
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix :
6 mm cement plaster of mix :
Meter
metre
Point
1:3 (1 cement: 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projection.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
Finishing walls with Acrylic exterior paint of required shade : :
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
New work (Two or more coats applied @1.67 ltrs/10 sqm over and and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Two or more coats on new work.
Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item.
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge.
With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and injecting chemical emulsion for pre/post constructional Anti-termite treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor,along the external perimeter of building,expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe and conduits with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to 1% concentration, labour, HOM of equipments, complete as per specifications.(plinth area of building at ground floor only shall be measured).
Supplying and stacking at site.
63 mm to 45 mm size stone aggregate.
53 mm to 22.4 mm size stone aggregate.
Stone screening 13.2 mm nominal size (Type ).
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2mm and 11.2mm size respectively per 100 sqm. and 52 kg. and 56 kg. of hot bitumen per cum of stone chippings of 13.2 mm and 11.2mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete.(tack coat to be paid for separately) :
With paving Asphalt grade VG-10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt.
Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road roller all complete.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10 including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
On WBM surface @ 0.75 Kg / sqm.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete
Inside size
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (medium duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Providing and fixing following PVC pipes alongwith necessary assesories and fitting (such as tee, elbow, bends etc )complete items
PVC pipe (150 mm nominal dia)
PVC pipe (100 mm nominal dia)
PVC pipe (80 mm nominal dia)
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with
seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
Providing and fixing viterous china wash basin (counter type) of approved make, size and colour, with 32 mm C.P. brass waste of standard pattern, including fittings and brackets, fasteners etc. complete in all respects as per the directions of Engineer in Charge.
15 mm nominal bore.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. brass basin mixer/pillar cock of approved make and quality.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing C.P. soap dish
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing 100 mm CP grating.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15 mm nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour
15 mm nominal bore with 30 cm length.
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c trenching and refilling.
25 mm dia. nominal bore
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :
Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
100 mm dia. pipe
With float glass panes of 4.0 mm thickness
Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the Architectural drawings and the directions of the Engineer in charge. (Cost of aluminium snap beading shall be paid in basic item)
Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)
Providing and fixing 100 mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium lock handles for aluminium sliding shutters.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
Providing and fixing 4.0 mm thick Fibre Cement False Ceiling (tiles of size 595x595 mm) conforming to IS 14862:2000, Type B Category 3, fixed on metal grid system comprising of hot-dipped galvanized interlocking metal T-section main runners, cross tees and wall angles, suspended from ceiling with dash fasteners, hangers, GI wire etc., complete as per manufacturer’s specifications and direction of Engineer-in-Charge
Providing and fixing 8 mm thick decorative PVC wall paneling of approved design, make, and color, including all matching uPVC accessories like corner trims, edge trims, and end caps, all complete as per the direction of the Engineer-in-Charge. The rate shall be for the finished area of the wall paneling
With float glass panes of 5.00 mm thickness
Providing structural drawing duly vetted by competent authority (DICQ/NIT/IIT or equivalent alongwith soil testing report) All complete work as per direction of Engineer-in-charge.
Surface preparation including cleaning of expansion joint and then installation of Hypalon strip thickness 150 mm with epoxy adhesive on both edges.
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Filling of Poly-urethane sealant with backup rod.
Fixing of aluminium strips, thickness would vary according to xize (150-300 mm) of shape of joint.
Single Pole
40 Ampere Triple Pole and neutral
40 amps SPN
63 amps SPN
63 Ampere Triple Pole
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
EARTHING AND LIGHTNING PROTECTION
Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
All metering current transformers shall be Class 1, 15 VA.
MDB-1 (Indoor Type)
Incomer (Power panel)
400 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
400 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp TPN - 6 No.
63 Amp TPN - 6 No.
40 Amp SPN -6 No.
63 Amp SPN - 6 No.
Incomer (Power panel)
400 A 4P MCCB – 1No.
Incomer (Light panel)
250 A 4P MCCB – 1No.
250A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Bus Bar
125 A MCCB 47 pole 36 KA-02 No.
100 A MCCB 4 pole 36 KA-02 No.
40 Amp TPN -4 No.
63 Amp TPN - 4 No.
40 Amp SPN - 4 No.
63 Amp SPN - 4 No.
Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required.
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way TPN
4 way TPN
12 way SPN
3.5C x 95sq.mm
3.5C x 120 sq.mm
Supply and fixing 1x20 watt with extruded aluminium tube light including connection testing etc. as reqd. (CCS-103-20-65-SL-DP-NWH) or equivalent in Wipro, Philips.
Supply and fixing of 18 Watt LED Panel surface mounted Aluminium body including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL)or equivalent in Wipro, Philips
Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-12-CDL)or equivalent in Wipro, Philips
Supply and fixing of 18 Watt LED Panel recess mounted aluminium body including connection testing etc as reqd.
Supply and fixing of 2x2 36 Watt recess mounted LED light including connection testing etc as reqd. (LCTLRNE-36-FO-CDL) or equivalent in Wipro, Philips.
Supply and fixing of 9 Watt LED mirror light 2' long including connection testing etc as reqd. (CAT No. LCTL-09-CDL)
Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing.
Supply and fixing of 150 Watt LED flood light IP 66 with all accessories including connection testing.
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with modular switch, modulr plate, suitable GI box and earthing the poi
nt with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp modular switch socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire.
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm with 1x6.0 sqmm earth wire
2x10 sq. mm with 1 x 6.0 sq. mm earth wire
4x6 sq. mm with 2 x 6.0 sq. mm earth wire
4x4 sq. mm with 2 x 4.0 sq. mm earth wire
Supply and fixing of 250 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Wiring for sub main wiring with4x10 sqmm alongwith 2x6.0 sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd.
Wiring for twin control light point with 2x1.5 sqmm PVC insulated copper conductor cable in surface/recessed ISI marked PVC conduit with 2 way 6 Amp switch
Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 Ampere and 5/6 Ampere modular socket outlet and 15/16 Ampere modular switch, connection testing etc as reqd.
Supply and fixing of 200 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing 2 module step type electronic fan regulator on the existing modular plate switch box including but excluding modular plate etc.
Supplying and fixing of 1200mm sweep ceiling fan BLDC 5 star rating including connection testing etc as reqd.
Supply and fixing Call bell / buzzer DC / AC single phase 230 V complete
Supplying and fixing of wall fan 16" including connection, texting etc. as required.
Supplying and fixing of exhaust fan 300mm sweep heavy duty trans air with double ball bearing including connection, texting etc. as required.
Supplying and fixing of exhaust fan 450 mm sweep heavy duty with double ball bearing including connection, texting etc. as required.
Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
Supply and fixing of 63 Ampere TPN in the existing Distribution board including connection testing etc as reqd.
Supply and fixing 2 Hp single phase monoblock pump set covered with shed of suitable size made of 16 SWG MS sheet including its painting and with small outdoor panel with bus bar 32 TPN with single phase starter including testing commissioning etc. required
Supply and fixing of 9 m SST poles in cement concrete pedestal 1:3:6 including excavation foundation (1:4:8) centering and shuttering of poles by engaging skilled labour with long rope complete job including cost of cement and carriage of pole from store to site.
Supplying and fixing of Mukki Clamp complete with nut, bolt etc. as reqd.
Supplying and fixing of U-Clamp alongwith 4" in size Shekel insulator with 6" long G.I. nut bolt complete job.
Supplying, laying, stringing and binding of LT conductor (Rabbit)
Supplying and fixing of stray rod complete with all accessories including digging of pit and refilling it with cement concrete (1:3:6) complete job including cost of cement.
Supply and laying of 2x10 sqmm aluminium cable complete connection testing etc as reqd.
Supply and fixing of bus bar 400 Ampere 3 phase with M.S. box 3ftx2ft approx. size including connection testing etc as reqd.
Supply, installation, testing and commissioning of 250 KVA capacity transformer level 2 step up/down outdoor type complete copper wound A.C. 3 phase 4 wire 50 Hz 250 KVA capacity step down outdoor 11000/433 volts (at no load) as per IS-1180 part-1:2014 (level 2) copper wound oil cooled with external cooling tubes/fans core type. The job includes platform of size (6'-0"x6'-0") 4 feet height including HT/LT line 1.2 kms approx. with SST pole 11 meter alongwith 11 KV GO/DO set, link set, LA set, earthing (4 Nos.) complete with Distribution transformer box including 400 Ampere MCCB 50 KA 4 pole 1 No. fuse set 400 Ampere-3 set complete job
Supply and fixing of following rating and breaking capacity with thermo magnetic release and terminal spreaders in the existing cubical panel board including drilling holes in the cubical panel making connection, testing etc as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TermsandConditionsoftheContract.pdf
Tender Documents • 0.22 MB
BOQ_967508.xls
BOQ • 1.77 MB
Facultybuildingdwg.pdf
Other Document • 2.84 MB
Download all tender documents and submit your bid