Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical responsive |
| 2 | Rejected-Technical | Rejected-Technical Not Responsive |
Tender Value
₹20.2 L
EMD Value
₹20,160
Closing Date
5 Mar 2026, 3:00 pmClosed
COMMISSIONER, PERIYAKULAM MUNICIPALITY
Municipal Office Katcheri Road Thenkarai Periyakulam PIN 625 601
Periyakulam Municipality - 15th CFC - Replacement of 250mm dia AC pipe to DI K7 pipe for pumping main at VOC Park to Bridge in Periyakulam Municipality
2026_MAWS_661781_1
306/2026/E1
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
MUNICIPAL OFFICE, PERIYAKULAM
Periyakulam Municipality - 15th CFC - Replacement of 250mm dia AC pipe to DI K7 pipe for pumping main at VOC Park to Bridge in Periyakulam Municipality
5 documents required · 5 mandatory
₹0
₹20,160
MUNICIPAL OFFICE, PERIYAKULAM
19 May 2026
20 Feb 2026
5 Mar 2026
20 Feb 2026
5 Mar 2026
24 Feb 2026
24 Feb 2026
Earth work excavation and depositing on bank with initial lead of 10m and lift 2m in narrow trenches having bed width 0.80 M & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers etc., complete complying as per standard specification
Supply and delivery of 250mm dia DI K7 pipe of IS standard cost including cost of all materials and conveyance to site and all labour charges etc., complete complying as per standard specification
Lowering 250 mm dia DI pipe into the trenches and laying to proper grade and alignment as directed by Departmental officers etc., complete complying as per standard specification
Refilling for pipe line works having bed width of 0.80 M and below on linear measurement basis consolidation works, levelling works, etc., complete complying as per TWAD standard specification
Disposal of surplus excavated earth in pipe laying and road restoration works etc.,transporting to the sites specified by Engineer within 2 Km lead, including unloading, spreading etc., complete and as directed by Departmental officers etc., complete complying as per standard specification
Supply and delivery of DI pipe specials of IS standard cost including cost of all materials and conveyance to site and all labour charges etc., complete complying as per standard specification
250mm dia DI K7 Bend 90o
250 mm DI D/F Gate Valve in 250mm DI main
150 mm DI D/F Gate valve for Scour in 250 mm DI main
80 mm DI Single chamber Air release valve in 250 mm DI main
Construction of SLUICE VALVE PIT of size 1.50 Mx 0.90 M x 1.50 M for 250 mm Main pipe, using brick work for side walls, as instructed by the departmetnal officers instructions and specifications, cost including all cost and conveyance of all materials to site, labour charges and all other costs etc., complete as per standard specification
Construction of Scour VALVE PIT of size 1.00 Mx 0.90 M x 1.50 M for 250 mm Main pipe, using brick work for side walls, as instructed by the departmetnal officers instructions and specifications, cost including all cost and conveyance of all materials to site, labour charges and all other costs etc., complete as per standard specification
Construction of DOUBLE AIR VALVE PIT FOR 250 mm main- 80 mm DAV of pit size 1.35 Mx 0.90 M x 1.20 M , using brick work for side walls, as instructed by the departmetnal officers instructions and specifications, cost including all cost and conveyance of all materials to site, labour charges and all other costs etc., complete as per standard specification
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished
Provision for GST 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.83 MB
Tendernotice_2.pdf
PDF • 0.52 MB
BOQ_794380.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid