| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.5 CrAccepted-AOC | ₹29.5 Cr Quoted ₹29.8 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹31.5 CrRejected-Finance | ₹31.5 Cr | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹35.0 CrRejected-Finance | ₹35.0 Cr | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected. Being adverse remarks in WLR for QE Dec 2023 issued by HQ CE Eastern Command. |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected. The firm has already secured two works in MES in capacity of un-enlisted firm. |
Tender Value
₹33.5 Cr
EMD Value
₹15 L
Closing Date
24 Apr 2024, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF KLP (PH-I OF TWO PHASES) AT DAHUNG UNDER GE 859 EWS
2023_MES_620724_2
98770/TENGA/SZ/E8
Open Tender
Civil Works
790 days
DAHUNG, TENGA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE 859 EWS
₹15 L
Yes
15 Jul 2024
19 Feb 2024
29 Apr 2024
19 Feb 2024
24 Apr 2024
10 Apr 2024
19 Feb 2024 - 26 Feb 2024
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,91,99,058.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,40,11,069.77 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,97,471.53 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 29,11,186.07 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT AND HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT AND HARDSTANDING” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 80,63,489.33 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,47,474.89 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' PART-VII)
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,85,821.64 inserted by the MES in Schedule ‘A’ Part-VII.
CHAIN LINK FENCING & STEEL GATE (Sch 'A' Part-VIII)
Lump sum price worked out by the Contractor for “CHAIN LINK FENCING & STEEL GATE” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 24,26,288.10 inserted by the MES in Schedule ‘A’ Part-VIII.
RETAINING WALL / RIVER PROTECTION WALL / GABION WALL (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “RETAINING WALL / RIVER PROTECTION WALL / GABION WALL” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,58,47,378.97 inserted by the MES in Schedule ‘A’ Part-IX.
STP (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “STP” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,36,061.55 inserted by the MES in Schedule ‘A’ Part-X.
(BLOWER SHED, RCC SUMP FOR TREATED WATER 6 KLD CAPACITY & SLUDGE COLLECTION CHAMBER 10 KLD CAPACITY & RCC UG SUMP 10 CUM CAPACITY) (Sch 'A' PART-XI)
Lump sum price worked out by the Contractor for “(BLOWER SHED, RCC SUMP FOR TREATED WATER 6 KLD CAPACITY & SLUDGE COLLECTION CHAMBER 10 KLD CAPACITY & RCC UG SUMP 10 CUM CAPACITY)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,71,201.16 inserted by the MES in Schedule ‘A’ Part-XI.
EXTERNAL WATER SUPPLY (Sch 'A' PART-XII)
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 10,88,002.77 inserted by the MES in Schedule ‘A’ Part-XII.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-XIII)
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 66,42,463.94 inserted by the MES in Schedule ‘A’ Part-XIII.
LIGHTNING PROTECTION (Sch 'A' PART-XIV)
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,44,869.20 inserted by the MES in Schedule ‘A’ Part-XIV.
SOLAR WATER HEATER (Sch 'A' PART-XV)
Lump sum price worked out by the Contractor for “SOLAR WATER HEATER” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 8,54,217.26 inserted by the MES in Schedule ‘A’ Part-XV.
WATER COOLER / REFRIGERATION (Sch 'A' PART-XVI)
Lump sum price worked out by the Contractor for “WATER COOLER / REFRIGERATION” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,91,462.95 inserted by the MES in Schedule ‘A’ Part-XVI.
WASHING MACHINE (Sch 'A' PART-XVII)
Lump sum price worked out by the Contractor for “WASHING MACHINE” as listed in Schedule ‘A’ Part-XVII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 26,911.36 inserted by the MES in Schedule ‘A’ Part-XVII.
DEMOLITION / DISMANTLING OF EXISTING BUILDINGS (Sch 'A' PART-XVIII)
Lump sum price worked out by the Contractor for “DEMOLITION / DISMANTLING OF EXISTING BUILDINGS” as listed in Schedule ‘A’ Part-XVIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,17,832.74 inserted by the MES in Schedule ‘A’ Part-XVIII.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIX)
INTERNAL WATER SUPPLY Supply & fixing two way bib cock with wall flange quarter turn (Low flow) 15/16 mm dia complete all as specified and directed.
Supply & fixing Pillar cock (Low flow) 15/16 mm dia complete all as specified and directed.
Supply & fixing bib cock with wall flange quarter turn (Low flow) 15/16 mm dia complete all as specified and directed.
Supply & fixing Hand shower (Health Faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed.
Supply & fixing Angular Stop Cock 15 mm bore pf pipe (16 mm outer dia) with wall flange chromium plated stop valve complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY S & F modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified and as directed.
S & F MCB 25/32 A modular type, SP conforming to IS 60898- 1: 2002 complete all as specified and directed.
S & F Modular type TV Co-axial socket outlet, 1 Module in the modular MS / GI sheet box and cover plate including connections etc complete all as specified and directed.
S & F Modular type RJ-11 telephone socket outlet, 1 module in the modular MS/GI sheet box and cover plate including connections etc Double RJ-11 in one Module complete all as specified and directed.
S & F 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF>0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed.
S & F DB with sheet metal enclosure SPN, 240 volts, 6 way, Single phase, double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete with driver and Lamp complete all as specified and directed.
Supply and fixing load line distribution board TPN vertical, 6 way, double door type, fixed on wall semi flush with incoming MCCB 4 poles 250 Amps, 16 KA, busbars , neutral link, blanking plates complete all as specified and directed.
S & F moulded case circuit breaker (MCCB) 80A, 4P, 16KA with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed.
S & F moulded case circuit breaker (MCCB) 160A, 4P, 16KA with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed.
ROAD, PATH & CULVERT M& L for 2 mm thick thermoplastic road marking materials hot making paint (minimum quantity of materials @ 2.02 gm per cum) of specified shade / colour using process by fully semi automatic thermoplastic materials applicator machine filled with profile shoe glass beads (minimum quantity of glass beads @ 250-300 gm per Sqm be embedding and acnhorin at depth of 50-60% adn should pressure type system having tank heater and profile shoe heater driven by exprienced operator on road marking materials should comply with BS-3262 Part-I 1:1989 complete all as specified and directed. NOTE : The work shall be executed by manufacurer's authorized applicators only.
Construction of RCC Culvert 1.5 m span x 12 m long / width, PCC (1:2:4), foundation, RR Masonry abutment wall, excavation in hard and dense soil PCC bed Block, PCC (1:2:4) wearying coat over slab, PCC (1:2:4) over water way, RR masonry parapet wall, RFR and removal of surplus soil complete all as specified and shown on drawing.
SECURITY FENCING AND STEEL GATE Construction of steel gate 5.5m wide and 2.3 m Height, with RCC pillars with necessary earth work PCC foundation, plastering, painting complete all as specified along with 1.2 m wide wicket gate of 1.2 m ht with another RCC pillar complete all as specified and shown on drawing.
PAKAGE TYPE STP 30 KLD CAPACITY Design Supply, construction, installation, testing & commissioning of Package type Sewage Treatment Plant 30KLD Capacity comprising of the following terms :- (i) Bar Screen (Mesh) MOC : MSEP / SS304, Fine Screen Mesh size 06mm-01 No (ii) Raw Sewage Pump-02Nos(1W-1S) Type : Cutter type Sewage submersible Make : Crompton /Kirloskar oe equivalent Head 10m Flow 1.5 cum/ hr (minimum) Item Continued as 19.19 to 19.23
(iii) Diffuser-08Nos Type :Tubular type MOC : Silicon Size: 63 mm dia X 625mm (iv) MBBR Media-3 cum Size : 63mm diaX10mm MOC PP Specific Gravity: 0.95 to 1 (v) Tube Setter-1.75cum Size: 700mm MOC: PVC Honey Comb Type
(vi) Fitter Feed Pump-02Nos (1W+1S) Type: Centrifugal Pump Make: Lubi/ Kirloskar Head: 40 m Flow 1.5cum/H (vi) Treated Water Pump-02Nos (1W+1S) Type : Centrifugal Pump Make : Lubi /Kirloskar Head: 30 m Flow 1.5cum/Hr (viii) Air Blower-02Nos (1W+1S) Type : Twin Lobe Root Make : Airvak Capacity :45 cum/hr Pressure : 0.35kg/Sqcm (ix) Air Piping-01 Lot Non submerged piping : MSEP/uPVC Submerged piping: uPVC Make of UPVC: Kishan/Astral/Supreme/Finolex Make of MSEP : Standard available.
(x) Liquid Piping-01 Lot Non submerged piping: uPVC-Sch-40 Submerged piping: UPVC-Sch-40 Make: Kishan/Astral/Supreme/Finolex (xi) Control Panel - 01 No Type of Panel: Automatic panel of micro controller base HMI Size: 7" Housing MSEP as required Mode of operation: Automatic/Manual Make of Panel: Enviro Engineers All working + Standby equipment will be change over automatic in case trip on equipment as well as cascade in operation blowers with VFD with auto operation of DO meter (xii) Pressure Sand Filter - 01 No MOC of Filter FRP Size of Filter: 330 mm dia x 1350 m Ht Material Weight: 150 Kg Make of pressure vessel: Pentair Multiple Valve: Automatic in operation through Pressure Transmitter (xii) Activated Carbon Filter-01 No MOC of Filter: FRP Size of Filter 330 mm dia x 1350 m Ht Material Weight: 100 Kg Make of pressure vessel : Pentair Multiple Valve Automatic in operation through Pressure Transmitter
(xiv) Disinfected Dosing System - 01 No Dosing Pump make: Vision/Verito Capacity of Dosing Pump: 0-4LPH Dosing tank make: Spectron or equivalent Dosing tank capacity: 50Ltr Dosing tank MOC: LDPE (xv)Pressure Gauge - 04 Nos Range: 0-7kg Make Brinda/Vision/La or equivalent Type: Bottom mounted (xvi) Pressure Transmitter - 03 Nos Range: 0-10kg Make Boumer/ARTACK/Danfoss Type: Bottom mounted (xvii) Level Sensor - 03 Nos Type: Float type level sensors (xviii) DO Meter - 01 No Type: Optical type Range: 0-20ppm No maintenance type (xix) Ultra Filtration: 01 No Flow: 1.5 cum/hr Make of UF : MOWS/Drop Saver Qua No of Module: 01 No
M&L for preparation of new plastered or unplastered surface and painting two coats of acrylic weather proof paint over a coat of primer complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply and laying Ductile Iron pipe S/S or Flanged type, Class-K-9 of size 150 mm dia complete all as specified and directed.
S&F Cast Iron Air Valves with two air Outlets, 150 mm bore and fixing Up in cast iron water supply mains complete all as specified and directed.
S&F foot valve, 80 mm dia, confirming to IS : 4028 complete all as specified and directed.
S&F mono block pumping set suitable for 415 V, 3 Phase system having capacity of 10 HP with copper cable single core 6 sqmm from starter to motor length as per rerquirement at site complete all as specified and directed.
S&F Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket Tee pieces single branch y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs for DI pipe complete set all as specified and directed.
Supply, installation, testing and commissioning in door type LT Panel box of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 2.00 mm thick, framing with suitable MS angle iron and legs of size 0.5 m long, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting root duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and grounted on floor complete with the following items housed in:- (Indoor Pump Panel) BUSBAR: 200 Amps rated/aluminium bus bar TPN duly insulated with coloared PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar. INCOMING (a) MCCB 4 Pole 100 AMP, 415 Volt, 50 HZ, rupturing capacity 25 KA-01 No (b) Change over switch 415 V 50 HZ 4 Pole 100 amp-01 No OUTGOING (a) Fully automatic star-Delta starter suitable for 415 V, 10-12.5 HP Motor-02 Nos (b) MCCB 4 Pole 40 AMP, 415 Volt, 50 HZ rupturing capacity 16 KA -04 Nos (c) MCB SPN 10 Amp 220 V, 50 Hz, 10 KA-02 Nos. (d) Voltmeter digital type-01 No (e) Ammeter digital type-01 No (f) LED indicator lamps complete (RYB) 01-set
M&L for construction of Solid PCC Block masonry valve pit of size (900x900x900 MM) (internal dimensions) 200 mm thick precast cement concrete solid block masonry wall in cement mortar (1:4) over 100 MM thick PCC (1:4:8) type D2 (Using 40 mm graded crushed stone aggregate) as in foundation, 15 mm thick rendering an cement mortar (1:6) internally, externally upto 15 cm below ground level provision of valve pit cover made out of 3 mm thick MS sheet welded with ISA 40x40x5 mm thick angle iron frame all round including provision of hinges, lifting handles, and locking arrangement fixed on top of valve pit by means of hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230x200x100 mm) including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and necessary earth work in hard/dense soil complete all as specified and directed.
M&L for construction of Solid PCC Block masonry valve pit of size (600 x 600 x 600 MM) (internal dimensions) 200 mm thick precast cement concrete solid block masonry wall in cement mortar (1:4) over 100 MM thick PCC (1:4:8) type D2 (Using 40 mm graded crushed stone aggregate) as in foundation, 15 mm thick rendering an cement mortar (1:6) internally, externally upto 15 cm below ground level provision of valve pit cover made out of 3 mm thick MS sheet welded with ISA 40x40x5 mm thick angle iron frame all round including provision of hinges, lifting handles, and locking arrangement fixed on top of valve pit by means of hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230x200x100 mm) including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and necessary earth work in hard/dense soil complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning out door type LT Feeder pillar box of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 3.15 mm thick, framing with suitable MS angle iron and legs of size 0 5m long duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Platform made out of PCC (1:3:6), complete with the following items housed in:- (Main Panel) BUSBAR : 800 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on Bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance. INCOMING (a) MCCB 4 Pole 400 Amp, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 35 KA-01 No OUT GOING (a) MCCB 4 Pole 200 Amp, 415 Volt, 50 Hz. thermal magnetic adjustable rupturing capacity 35 KA -01 No (b) MCCB 4 Pole 100 Amp, 415 Volt, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA - 02 Nos. Item Continued as 19.34
Supply installation, testing and commissioning outdoor type LT feeder pillar box of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 3.15 mm thick, framing with suitable MS angle iron and legs of size 0.5m long duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Platform made out of PCC (1:36), complete with the following items housed in :- (Panel No. 01) BUSBAR :- 200 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance. INCOMING (a) MCCB 4 Pole 100 Amp. 415 Volt, 50 Hz thermal magnetic adjustable rupturing capacity 25 KA 01No. OUT GOING (a) MCCB 4 Pole 25 Amp, 415 Volt, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA-01 No Item Continued as 19.36
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 3.15 thick, framing with suitable MS angle iron and legs of size 0.5m long duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heal process of sheet and suitable for 500 volts. 50 Hz. 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC (1:3:6) complete with the following items housed in:- (Panel No 2) BUSBAR : 300 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on Bakelite/DMC insulator bus bar support (Square/round) Insulators of suitable size and good insulation resistance INCOMING (a) MCCB 4 Pole 200 Amp, 415 Volt, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA -01 No. OUT GOING (a) MCCB 4 Pole 25 Amp, 415 V, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA-06 No Item Continued as 19.38
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedestal mounted CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 3mm thick, framing with suitable MS angle iron and legs of size 0.5m long duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC (1:3:6) complete with the following items housed in: (Panel No. 3) BUSBAR : 200 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on Bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance INCOMING (a) MCCB 4 Pole 100 Amp, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 16 KA -01 No Item Continued as 19.40
Supply, installation, testing and commissioning out door type LT feeder piller box of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of suitable CRCA sheet 3mm thick, framing with suitable MS angle iron and legs of size 0.5m long duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heal process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC (1:3:6) complete with the following items housed in: (Panel No. 4) BUSBAR : 100 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on Bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance INCOMING (a) MCCB 4 Pole 63 Amp, 415 Voll, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA -01 No OUT GOING (a) MCCB 4 Pole 40 Amp, 415 V, 50 Hz, thermal magnetic adjustable rupturing capacity 16 KA-01 No (b) MCCB 4 Pole 25 Amp, 415 V, 50 Hz. thermal magnetic adjustable rupturing capacity 16 KA-01 No Item Continued as 19.42
S&F Solar street light system 36 Watt including in built SCC, SPV Panel 150Wp, Lead Acid Battery 12 Volts, 120 AH mounted on Sheet metal box of suitable size at 3.0 Mtr height, GI Tubular pole 7.5 Mtr long and 6.0 Mtr above ground level and earth work complete all as specified and directed.
S&F junction box IP 66 thermoplastic polycarbonate enclosure totally shock proof sate weather proof, rust proof, dust proof, water proof, halogen free, silica free having internally embedded gasket technology with glow wine test at 96 C of size 200X160X98 mm with epoxy terminal, MS clamp SP MCB 6 amps and 4 pole connectors of 16 Amp capacity cable glands lock nut including bracket with necessary arrangement for fixing complete for street light poles complete all as specified and directed.
DG SET Supply, installation, testing and commissioning Silent type built in within an acoustic enclosure Diesel Engine driven Generating set Air cooled including AMF panel for standby power supply 415 volts, 3 Phase, 4 wire, 50 cycles / sec,0.8 power factor, 20 KVA or next higher standard size available KVA,1500 RPM. Self-excited self-regulated brushless AC generator installed. The alternator directly coupled to diesel engine, mounted on common base frame & complete with self-starter 12 volt. Acoustic enclosure suitable for ambient condition at DAHUNG and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 to meet exhaust emission test as per revised MoEF norms/as per CPCB. Fuel tank capacity not less than 08 hours fuel requirement & battery as recommended by OEM battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller with the following under-mentioned features & all as specified & as directed. NOTE : The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. (A) Alternator :- Standard design alternator rated at 20 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire, 415 volts, 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. Item Continued as 19.46 to 19.51
(i) Insualation class - 'H' (ii) Temparature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with + 1%. (v) Frequency regulation + 1% (B) Diesel Engine: - Adequate capacity of Diesel engine air cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete, with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. MS Exhaust pipe with bends/flanges and all accessories to be supplied and erected as per OEM recommendation. The Exhaust Pipe shall be insulated with low resin bounded wool of min 75 mm thickness min 144 Kg/m density. The dia/thickness and Stack height of the Exhaust pipe shall be as per OEM recommendation and CPCB norms. The minimum height of Stack to be provided with each generator set shall be worked out as per CPCB norms. Turbo charger type Exhaust manifold Silencer : Residential type
(v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses. (vi) Lub oil System :- Comprising of Lubricating oil filter, Lubricating oil pump etc. (vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc (viii) Governer :- Electronic type (ix) Starting System :- Electric Self starter with and including battery charging alternator 24 Volts DC. (x) Batteries :- Batteries of maintenance free of suitable capacity 12 V, as per OEM Tech Spec complete with copper conductor multi-stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. Start and stop push button Ignition key / Switch Radiator with blower fan & first fill of coolant oil Corrosion inhibitor coolant (xi) Generator Monitoring Panel:- Comprising of all standard items as per standard manufacturing, ignition key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. (xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine. (xiii) Coupling arrangement : - Flexible coupling (xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.
(g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage. (v) Over voltage, under voltage and over current (vii) Display shall be alphanumeric LCD display with LED backlight. Controls and Records:- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept / reset push button (f) Battery Charger shall be provided as per manufacturer guidelines (g) Suitable to provide a record of most recent fault conditions & fault history. (h) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc. (j) Complete engine data viz, starting battery voltage, engine temp, engine runnning hours, engine oil pressure etc. (k) Control incl provn of service adjustment & calibration of DG control functions. (D) Civil Works :- All civil works including PCC plat form and related foundations including for panel and equipment’s including making good of disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer.
NOTE : The contractor shall arrange for artificial resistive load for testing of DG Set at site and the cost is deemed to be included in the above offer. (E) Acoustic Enclosure:- Manufactured by OEM suitable for 20 KVA DG Set. (i) Tested by NABL approved lab as per latest CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure. (iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level (vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external Emergency stop push button. (viii) The enclosure should be suitably internally illuminated by LED Lamp fittings. (ix) The noise level should be 75 dB at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
All as per Srl Item No. 19.45 to 19.51 but for 62.5 KVA complete all as specified and directed.
WATER COOLER S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity of 1 KVA complete all as specified and directed.
REFRIGERATION S&F refrigerator, electric driven (single phase), capacity 195 Litres, frost free, BEE 5 star rated complete all as specified and directed.
S&F refrigerator, electric driven (single phase) double door of capacity 310 Litres, frost free , BEE 5 star rated complete all as specified and directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity of 2 KVA complete all as specified and directed.
WASHING MACHINE Supply and installation washer extrator machine 30 Kg Capacity per charge, electric heated front loading, soft mount high spin etc complete all as specified and directed.
Supply and installation drying tumbler machine 30 Kg Capacity per charge, electric heated front loading, complete body in galvanised sheet complete all as specified and directed.
FIRE FIGHTING S&F Fire Extinguiser water CO2 / stored pressure type, 9 Kg capacity complete all as specified and directed.
S&F Fire Extinguiser water CO2 / stored pressure type, 6.5 Kg capacity complete all as specified and directed.
S&F Fire Extinguiser dry chemical powder (ABC) type, 6.5 Kg capacity complete all as specified and directed.
Supply only fire breater complete all as specified and directed.
Supply only fire hookar complete all as specified and directed.
S&F fire bucket (Water / sand) set of 2 with stand duly recommended collar and clearly written complete all as specified and directed.
M&L for construction of fire point structure complete for housing of fire bucket 2 Nos., fire extinguisher - 2 Nos., fire biter -1 No. and fire hook - 1 No. complete all as specified and directed.
M/S N C BANERJEE AND SON
M/S TSERING DHONDUP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid