Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.8 L+₹73,539.30 (5.24%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.3 L+₹1.3 L (9.14%)Rejected-Finance ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.4 L+₹1.4 L (9.78%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.5 L+₹1.4 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹19.9 L
EMD Value
₹39,800
Closing Date
21 Oct 2019, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor
SPL REPAIR TO BLDG NO P 52 SINGLE JCOs LIVING ACCN P 49 WELDING SEC AND P 37 OFFICE COMPLEX AT AKHNOOR UNDER GE NORTH AKHNOOR
2019_MES_284512_1
GE(N)/AKH-21/2019-20
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
E Class Cat a i b i
8 documents required · 8 mandatory
₹500
GE North Akhnoor
₹39,800
Yes
2 Apr 2020
23 Sept 2019
23 Oct 2019
23 Sept 2019
21 Oct 2019
8 Oct 2019
Amount
Dismanting and removal old roof treatment incl concrete paddding, removing existing bitumen felt treatment incl brushing,cleaning top surfaces of roof slab,broming etc of existing roof treatment of any description including cleaning and washing the surface complete all as specified.
15mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction, complete all as specified and directed.
Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 4.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrance and dusted with dry sand @ 0.50 to 1 Kg/sqm.
Note : (i) Roof treatment work shall be carried out through approved manufacturers only. (ii) If Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (iii) Covered fillet in PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).
Precast cement concrete tiles, machine pressed, factory made of 20mm thick on roof surfaces etc with grey cement and pigment, set, jointed in neat cement slurry and pointed in grey cement, cut and polished, over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified.
Non skid Ceramics tiles grade B-IIa coloured of size 400x400x7mm thick set & jointed in neat cement slurry and pointed in white/coloured cement to match incl 15 mm thick screed bed/bedding layers in CM 1:4 incl dismantling floor, hearth or wall tilling complete all as spd & directed.
Non skid Ceramics tiles grade B-IIa coloured of 6-7mm thick area of each tile exc 0.06 Sqm and n.exc 0.11 Sqm in floors etc. set & jointed in neat cement slurry and pointed in white/coloured cement to match incl 15 mm thick screed bed/bedding layers in CM 1:6 complete all as spd & directed.
Glazed ceramic tiles coloured (Premier quality) of size 450 x 300 x 7mm thick, jointing in neat cement slurry and pointing in colour cement to match including incl 10mm thick plaster in CM 1:4 incl dismantling floor, hearth or wall tilling all as spd and directed. Glazed ceramic tile shall be conforming to IS-13712 of 1993 all as spd and directed.
Vitrified ceramic tiles light shade 10 mm thick (square /rectangular ) double charged polished, area of each tiles not exceeding 0.36 sqm ,in floors etc set and jointed in neat cement slurry and poined in white or coloured cement to match including 15cm thick screed bed or bedding layer of mortar in CM 1:4 for floor tiles including dismantling floor or wall tiling all as specified and directed
Taking down chowkats or frames exceeding 1.5 Sqm and n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) all as specified and directed
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) all as specified and directed
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm including tarring ends and back of chowkats and lugs including back filling of PCC 1:3:6 for chowkats & PCC 1:2:4 for block for hold fast including two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces all as specified and directed
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 105x60mm including tarring ends and back of chowkats and lugs including back filling of PCC 1:3:6 for chowkats & PCC1:2:4 for block for hold fast including two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces all as specified and directed
35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated and fitted to chowkats complete all as spd.
35mm thick, 2nd class hard wood glazed and skelton shutter, open rebated and prepare to receive glass, gauzed etc(without sash bars) edges of framming plain , chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR PART I Section 8 clause 8.24(a) supplied and fitted to chowkhat complete all as spd.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
Steel windows/ventilator (Box type) factory made with double shutter (wire gauged shutter & glass/glazed shutter, (wire cloth and glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, two coats of synthetic enamel paint over one coat of red oxide primer including taking down old windows/ventilators all as specified & as shown on drg No. CEUZ/TD/1269 /2008 Sh no 1/1 to 1/3 .
Aluminium anodised door frame with shutter comprising of aluminium door frame of rectangular tube of size 101.60x44.75x2.4mm thick and aluminium glazed and skelton shutter with bottom rail of size 105x44.45x2.20mm thick lock rail of size 150x44.5x3.00mm thick, 5.5mm thick glass with solar control film 25 micron reflective type sticked to glass and dixed in shutter incl necessary rubber packing/gasket aluminium clips/beading of 0.9mm thick and shutter shall be provided with locking arrangment with godrej mortice lock of seven levers aluminium tower bolts of size 200mm 02 nos and circural aluminium handles of 101.60mm dia and 2.54mm thick 02 Nos 03 Nos of Butt hinges (100mm) and 01 Nos of hydraulic door closer extruded section body incl taking down old ones complete all as specified and directed.
Anodised aluminium frame & grill for windows/ ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Aluminium window and ventilator shutters, side hung type without sash bar , aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos) suitable handle (1 nos) incl 5.5mm thick glass with solar control film 25 micron reflective type sticked to glass and dixed in shutter complete all as specified and directed.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanized wire staples all as specified & directed.
03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed by Engineer-in-Charge.
Floor door stopper 150mm length of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as spd.
300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and as directed by Engineer-in-Charge.
Aluminium handles fabricated type anodised of size 150 mm long ISI marked complete all as specified and as directed by Engineer-in-Charge.
300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete.
200 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed by Engineer-in-Charge.
Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified.
Demolition of brickwork or stone boulder masonary built in cement or cement lime mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer -in-Charge.
Brick work with Sub Class ‘B’ burnt bricks (Old size bricks) straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete, all as specified.
Brick work with Sub Class ‘B’ burnt bricks (Old size bricks) straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete, all as specified.
Ditto all as per Srl item no. 32 above but except brick.
Rendering 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement with integral water proofing compound including taking down existing plaster and two coat of cement base paint over a coat of primer complete all as specified and directed.
Rendering 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement with integral water proofing compound and two coat of cement base paint complete all as specified and directed.
Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement including taking down existing plaster and two coat of oil bound distemper over one coat of primer & preparation of surface complete all as specified and directed
Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement and two coat of oil bound distemper over one coat of primer & preparation of surface complete all as specified and directed
3mm thick wall putty on wall complete all as specified and directed.
Rendering 5 mm thick cement plaster in cement mortar (1:3) on brick or concrete surfaces of soffits of chajjas, roof projections or ceiling and finished even and smooth without using extra cement including taking down existing plaster and three coat of white wash complete all as specified and directed .
Repairs to balcony/Facia and soffit of chajjas etc by taking down old rendering 20 to 25 mm thick to match with the existing thickness in CM 1:3 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm cm in width or girth incl preparatoin of suface and two coat of cement base paint /apex as reqd over primer complete all as specified.
Preparation of old decorated plaster ed or un-plastered surfaces of walls and applying one coat of Acrylic Emulsion Exterior paint on walls/ceilings/facia. all as specified and directed.
50 mm thick PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including 75mm thick consolidated hard core of broken stone over rammed earth finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work/screed strips and to divide the area in panels.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified.
25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate, as in sub base of floor complete all as specified and as directed by Engineer-in-charge.
PCC 1:2:4 (nominal mix), type B-0 using 12.5mm graded crushed stone aggregate, laid in alternate panels as in floors complete all as specified & directed.
Chequerred cement concrete prelaminated rubberized coloured tiles 30 cm x 30 cm x 25mm thick factory made with grey and no pigment, set, jointed and pointed in neat cement slurry in floors including 20 mm thick screed bed in cement and sand mortar 1:4 finshed even and fair to receive tile complete all as specified.
Machine made precast cement concrete interlocking pavers block any shape and size of 80mm thick M-35 grade confirming to IS 15658-2006 laid over 25mm thick sand cushioning over 100mm thick PCC 1:5:10 type E 2 using 40mm graded stone aggregates. The interlocking joints shall be filled with fine sand. Both sides of path should be finished with concrete 1:2:4 type B2 (using 20mm graded aggregate) as in stops 5cm wide and depth upto subbase all as spd and directed.
Painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified.
Preparation of old painted surfaces of walls by washing, rubbing, stopping, brooming down with steel wire brushing scrapping down smoke roots, moulds salts and trading oil and greasy spots s complete and providing one coat of cement base paint including curing before and after providing of one coat all as specified and directed.
Preparation of old decorated plaster ed or un-plastered surfaces of walls and applying one coat of oil emulsion paint (oil bound distemper) on walls using POP/cement wall putty to fill the spotand undualating surface all as specified and directed.
Looking mirror of size 24"/30" fancy type economy range fixed incl fixed in repair complete all as spd.
Vitreous China ware wash hand basin white incl full padestal of size 560x430mm x 195mm incl all fitting accessories ,CP waste coupling and PVC waste pipe all as spd and as directed. Make : Jaquar, Cat part No.: CNS-WHT-811 and CNS-WHT-303 or equivalent as approved by GE.
15mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including taking down existing water tubing complete all as specified.
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including taking down cleaning for refixing, complete all as specified and as directed .
20mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including taking down existing water tubing complete all as specified.
Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including taking down cleaning for refixing, complete all as specified and as directed .
CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore fixed in repairs complete all as spd and directed. Make : Jaquar, Cat part No.: ORP-10053PM or ORP-10083PM or equivalent as approved by GE.
Stop valve cast copper alloy (ISI Marked) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm bore fixed in reapirs complete all as specified and directed.
Stop valve cast copper alloy (ISI Marked) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 20mm bore fixed in reapirs complete all as specified and directed.
CP Bib taps cast copper alloy, fancy type ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 15mm bore fixed in repairs complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 450mm size complete all as spd and directed.
Cast iron floor traps dia meter of outlet 75 mm with grating including jointing to waste pipe fixed in cement concrete type B-I, 1:2:4 all as specified (using 20 mm graded crushed stone aggregate) complete all as specified.
CP Grating with frame and cover for 150x150mm size hole square/round fittings of 100 mm dia made two parts for smell and chockroch proofing including embedding in tiles with white cement complete all as specified & directed.
Stainless steel Towel Rail ,600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed. Make : Jaquar, Cat part No.: ACN-1111SM or equivalent as approved by GE.
Chromium plated brass toilet paper holder fixed to walls with brass screws in repairs, complete all as specified and as directed. Make: Jaquar, Cat Part No.AHS-1551 or equivalent as approved by GE.
CP Fancy type Liquid soap dispenser, fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and as directed. Make : Jaquar, Cat Part No. CAN-1135 or equivalent as approved by GE.
PVC SWR pipes 110 mm dia single socketed in any length with rubber rings, joints laid in trenches or in floors incl taking down existing pipe complete all as spd and directed.
PVC (SWR) bend 110mm bore all as spd and directed.
PVC SWR gully trap 125/110 mm setting and jointing with solvent cement complete all as spd.
PVC floor trap with grating suitable for 100mm dia outlet and jointed to waste pipe in run led complete al as spd.
100mm dia PVC (SWR) junction single (single T) equal or unequal.
Chromium plated fancy type pillar tap with lift type operating knob and base flange ,15 mm bore dia.all as specified and as directed. Make : Jaquar, Cat part No.: FLR-5015 or equivalent as approved by GE.
MS with PVC coated decorative 25mm curtain rod with fixing brackets etc complete fixed in repair all as specified and directed.
Rotational moulded polyethiene water storage tanks of capacithy 500 litres, (cylindrical vertical with closed top) hoisted and fixed in position including necessary GI fittings, inlet/outlet washout, overflow piecces long nipples, checknuts and washer etc including dismantling existing water tanks of any description complete all as specified and directed.
Ditto all as per item No 74 but capacity 1000 litres.
Ball brass valves high pressure, with polythene float and fly nut complete, screwed from iron pipe or brass ferrule size15mm complete all as specified & directed.
Vitreous china wash down water closet pan (S-trap) white (size 370 x 690 x 680mm) with Seat cover ,Hinges and flushing cistern (Single piece) incl all fittings incl makeing connection to trap and to flush pipe incl fixed in repair complete all as spd and directed Make : Jaquar, Cat part No.: CNS-WHT-851 or equivalent as approved by GE.
Hand shower (health faucet) with 8mm dia .1.2 Mtr long flexible tube and wall hook, fixed in repair, complete all as specified and as directed. Make : Jaquar, Cat part No.: ALD-573 or equivalent as approved by GE.
Soap dish/holder CP in repair as per cat part No ACN-1131N OF JAQUAR or equivalent as per list of make complete all as specified and directed.
Glass shelf assembly fixed in repair
18/19 mm thick pre-laminated particle board, interior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in shelves and shutter, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F steel rolling shutter 1.25mm thick lath thickness, gear operated type with chain wheel and hand chain incl ball bearing, top cover anchoring rod, hasp and staple,safety lever lock mild steel two coat of synthetic enamel paint over one shop coat of red oxide primer, executed in position incl taking down complete all as specified.
Machine cut Kota stone slab 20-25 mm thick as in floors set and jointed with grey cement slurry mixed with pigment to match the shade of slab including white marble in border (100 mm width) including rubbing, rounding off edges grinding and mirror polishing (size of slab not less than 55 cm x 55 cm) including provision of screed bed 15 mm thick in cement martar 1 : 4 and taking down old floor/tile/kota stone incld cement mortar complete all as specified.
Ditto all as per item No 83 but as in vertical surface like riser of steps, skirting, dado etc.
Cast iron soil, waste and vent pipe, sand cast, 75mm bore in any length with or without ears with cement joints, laid in trenches or in floors or fixed to walls with stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified & directed.
Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
Framed work for cooler stand /doors or gates of angle iron fixed with window upto two storey bldg including 100X100X100 mm cutting brick work /stone masonry/ cement concrete & filling with PCC 1:2:4 & making good complete all as specified and directed by Engr–in–charge.
Cement concrete (1:3:6)type C-2 using 40mm graded aggregate as in surface channels and drains complete all as specified and directed.
Formwork fair finished surface to sides of concrete foundations, footings, bases of columns, raft beams, sides and soffits if any of foundations and beams; and similar work ; vertical or to batter complete all as specified and directed.
Supply only water proofing compound
CP Brass wall mixture with provn of overhead shower for mixing hot and cold water supply screwed down incld connecting legs & wall flange for iron pipe 15mm bore dia in repair complete all as specified and directed. Make : Jaquar Cat Part No CON-273KNUPR and OHS-1709 or equivalent as approved by GE.
Taking down carefully copper/aluminium point wiring (light,fan , llight socket or power socket) complete, incluing fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc.
Taking down main switches, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/ portion of walls etc. all as directed.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
M&L for concealed Sub main wiring of two run with 06 sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through PVC conduit 20mm dia , med grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceilling, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLS , multi stranded copper conductor cable as earth continuity conductor in green color, connected to common earth dolly complete all as specified and as directed.
M&L for concealed Sub main wiring of two run with 04 sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through PVC conduit 20mm dia , med grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceilling, including cutting /chasing as required and its accessories including one run of 04 Sqmm single core PVC insulated, FRLS , multi stranded copper conductor cable as earth continuity conductor in green color, connected to common earth dolly complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn through PVC conduit 20 mm dia, med grade , ISI marked and fixed in concealed surface of wall , ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as specifed and directed by Engr in -charge for the following :- (a) One light/fan point controlled by one on way switch
(b) One socket outlet 05 Amps on the same board
(c) One socket outlet 05 Amps on independent board
M&L for concealed point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn into PVC conduit 20 mm dia, medium grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as pecifed and directed by Engr in -charge. NOTE FOR SER NO 97TO 100: (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one RM. (b) Rate are inclusive cutting chases of bricks and making good to disturbed surfaces when ever required. (c) Proper colour coding should be adopted for phase, neutral and earth .
Supply and fix in replacement of 5 and 15 Amps Switch socket combination, 2 in 1, 6 pin, flush type multi purpose, all as specified.
S& F of Ceiling rose, 5 Amps surface type 240 volts bakelite three terminal as ordered and directed .
S&F of Switch piano, single pole one way 5 Amps 240 volt capacity flush type all as specified.
S&F in replacement of bell push piano flush type 5 Amp
S&F of 5 pin, 5 Amps Switch Socket combination flush type multi purpose 2 in 1 type (2 pin and 3 pin) and all as specified and directed.
S& F of Socket out let 5 pin, 5 amp flush type on same board.
S&F of Fan regulator electronic step type 230 volts suitable for any type of ceiling fan sweep on the existing phenolic laminated sheet etc all as specified and directed.
S&F in replacement of bell ding dong AC 230 volt single pole.
S&F of Lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings, all as specified and directed.
Supply and fix LED lamp 1 x 10W retrofit type lamp suitable for holder.
Supply & fix of sheet metal enclosure double door type for DBs single pole and neutral 8 way 240V with 200 Amp bus bar including blanking plates where required.
Supply & fix of sheet metal enclosure single door type for DBs single pole and neutral 4 way 240V with 200 Amp bus bar including blanking plates where required.
S & F MCB Single pole & neutral 240 volt, 40 Amps, "C " series.of 10 KA repturing capacity.
S&F MCB Single pole 240 volt, 6 to 32 Amp, "B" series.
M & L for Earthing complete with Steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level ) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanized iron earth wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel earth wire protected by provision of GI medium grade pipe 15mm bore including provn of concreate pit made from PCC 1:2:4 type B1(using 20 mm graded stone aggs) with 17mm thick cover of RCC (1:2:4) re-inforced with XPM (weight not less than 4 kgs per Sq mtr and frame of angle iron 25 x 25x 6mm with lugs to 02 Nos and with 6mm dia MS bar handle made to safe GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point made out of 17mmx 8 mm FI with fixing arrangement , funnel , wire mesh and earth work in hard dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 mtr all as per electrical plate No 3 of SSR 2010 part I connected to earth test point. All as specified or indicated including testing on completion. Note : 1. The rate quoted is deemed to be included the followings :- (a) Excavation and earth work (filling in,ramming in layers, watering etc. as directed) in any type of soil for earth pit. (b) Perforated GI tubing light grade 40 mm bore dia 1.8 mtrs long for strip protection and watering. (c) Common salt and charcoal dust in alternative layers of 15 cm up to 60 cm above the top of copper plate all as directed. (d) Earth pit of internal size 600 x 600 x 600 built in PCC (1:3:6) bed 15 cm thick at bottom , brick work in CM up to 45 cm over PCC bed and PCC (1:3:6) coping 15 cm above embedded with MS angle 50 x 50 x 3 mm frame work duly painted with anti- corrosive bituminous paint, with and inclding RCC slab 50 mm thick in cement concrete (1:2:4) type 1, reinforced with XPM (weight not less than 4 Kg per Sqm) having lifting arrangement duly painted in green color and marking earth pit as directed. 2. On testing , after completion , if the earth resistance equal or less 2 ohms is not obtained , earthing will be regenerated at no extra cost till the disired earth resistance is obtained.
Taking down to ceiling fans and hanging the same and connecting up including provision of cable from ceiling rose or connector to fan as directed by Engineer-in-Charge.
Preparation of old surfaces of ceiling fans by scraping out old existing paint with the help of emery paper/wire brush including filling the cavities and painting with two coats of white synthetic enamelled paint over a coat of red oxide primer with the help of spray machine including re-writing MES No SL No with black synthetic paint in Capital letter for 1200/1400 mm sweep ceiling fan, complete all as specified.
New generation energy saving and environmental friendly long life LED street light of 20W made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection and impact resistance of IK07 including GI bracket made of 32mm dia light grade GI tube 1.2 metre bend to shape with 02 nos FI clamp of 32x4mm with nuts, bots, washers, making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make : Havells Cat Part No. ENDURACITYLITEPLAT SL20WLED757 SASY BOPC or equivalent of Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
S & F Wall/Surface mounted LED batten, 20 W, 230 V, extruded aluminium provided for efficient heat dissipiation with polycarbonate diffuser & integrated electronic driver complete including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make- Havells, Cat No ENDURALINEARNE OBS20WLED865SPCWH or equivalent in CG/Philips/Bajaj etc.
S& F of Energy saving 10 Watt LED Bulk head luminaries, 230V, 50Hz with oval shape, surface mounted, comprising high brightness LEDs complete all as specifed and directed. Make- Havells, Cat part No RUGBYNET10WLED760SS YMBOPC or its equivalent in Bajaj/ Philips/ Crompton Greaves etc.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Supply, and laying/fixing or passing through pipe 1100 volts grade heavy duty electric cable with XLPE insulated screened PVC bedded aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of size 6 Sq mm 2 core in trenches, on poles and in ducts. Note : Excavation, earth work, bricks and sand cushioning shall be measured and paid separately.
Excavation in trenches n.exc 1.5m in width and n.exc 1.5m in depth and getting out in any type of soil for laying pipe line, laying cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, all as specified.
Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, all as specified .
Sand cushioning to under ground cable in trenches/ducts in layers of 8 cm thick before laying the cable and 15 cm thick after laying and stretching the cable, complete all as specified.
Supply and laying Sub Class 'B' common burnt bricks, old size, laid dry, flat transversely along the length of cable with width equal to length of brick & with gaps between the adjucent bricks not exceeding 10mm as cover laid over the cable to give mechanical protection to under ground cable complete all as specified & directed.
Steel tubing galvanised (light grade) 40mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50 x 6mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as specified.
S&F on load change over switch 240V in sheet metal enclosures 2pole of capacity 63 Amps.
JR CONSTRSTRUCTION CO.
SHIVAM CONSTRUCTION COMPANY
M/S Rajesh Kumar Contractor
M/s Vishwakarma Enterprises
M/s Joginder Lal Malhotra
KRISHNA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .