Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹46.3 L+₹5.4 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹46.9 L+₹6.0 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹47.0 L+₹6.1 L (14.9%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹50.4 L+₹9.5 L (23.2%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance Rejected |
Tender Value
₹55.1 L
EMD Value
₹1.1 L
Closing Date
30 Dec 2019, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPECIAL REPAIRS TO BUILDING NO. P-02/01 TO P-02/12 AND BUILDING NO. P-94/01 TO P-94/08 (OR MARRIED ACCOMMODATION) AT MILITARY STATION LALGARH JATTAN
2019_MES_284725_1
CA NO. CWE SGNR - 42 OF 2019-20
Open Tender
Civil Works
Item Rate
120 days
GE LALGARH JATTAN
Class C
Category a(i)
10 documents required · 10 mandatory
₹1,000
GE LALGARH JATTAN
₹1.1 L
Yes
11 Jan 2020
25 Nov 2019
2 Jan 2020
25 Nov 2019
30 Dec 2019
16 Dec 2019
Amount
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone /boulder masonry, built in cement mortar or cement lime mortar including all quoins, pillars etc of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3 Kg of cement per Square metre complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description from brick walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38sqm on vertical surface such as skirting/dados and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles 450mmx350mmx7mm thick as in vertical surface on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of approved type and colour) work (table rubbed and polished) as in cooking platforms, stair case landing or steps and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with approved shade of granite including cutting and moulding the edges half round on exposed side over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm to 25 mm thick machine cut Kota stone slab of size 55cm x 55cm (minimum) as in flooring laid over cement mortar screed base, jointed with grey cement slurry mixed with pigment to match the shade of slab over and including 15mm thick screed bed in CM 1:6 including rubbing, grinding and polishing complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm to 25mm thick machine cut kota stone slabs as in vertical surfaces such as risers of steps, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing also moulding edges laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M & L 75mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded crushed stone aggregate) as in sub base complete all as specified and directed by Engineer-in-charge.
M & L for factory casted precast kerb stone of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate of 300mmx300mmx100mm size with plain fair faces, including chamfers, weatherings, throating etc and set in Cement Mortar 1:4 including necessary form work, excavation and earth work for embedding kerb stone at a depth as directed & temping around kerb stone and removal of surplus soil to a distance n.exc 50 metre & depositing where directed complete all as specified and directed by Engineer-in-Charge.
M&L for 60mm thick precast machine pressed coloured interlocking paving blocks M-35 grade using grey cement and pigment, of any shape and size conforming to IS 15658-2006 laid over and including 50mm thick layer of sand including filling the interstices complete all as specified and directed by Engineer-in-Charge.
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished complete all as specified & directed by Engineer-in- charge.
Material and labour for reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate as in chajjas and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
M & L for mild steel reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9 mm dia, complete all as specified & directed by Engineer-in- charge.
S & F mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in- charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces of wall in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm thick rendering in cement mortar (1:4) on fair faces of concrete surfaces of ceilings finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of distemper oil emulsion including 3mm thick wall care putty complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces of wall and applying two coats of distemper oil emulsion including 3mm thick wall care putty complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface of wall and applying three coats of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall and applying two coat of white wash complete all as specified and dir by Engr-in-Charge.
M&L for preparation of new plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling and applying two coat of white wash complete all as specified and dir by Engr-in-Charge.
M&L for preparation of new plastered or unplastered surface of walls and applying two coats of cement based paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or pointed surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moss and efflorescent salts and applying one coat of cement based paint complete all as specified and directed by Engineer-in-Charge.
M&L for broken brick hardcore of gauge not exceeding 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement including 10mm wide, 30mm deep joints at the rate of 3.00mtr centre to centre and at every turning & filling the joints with bitumen & sand mixtue complete all as specified and directed by Engineer-in-Charge.
M & L for continuous brick edging (sub class ‘B’) with width equal to the width of brick laid dry, on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified.
Material and labour for brick work in wall using Fly Ash bricks (old size bricks) straight or curved on plan to any radius built in cement mortar (1:6) complete all as specified & directed by Engineer-in- charge.
Material and labour for brick work in half brick thick wall using Fly Ash bricks (old size bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified & directed by Engineer-in- charge.
M&L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Dismantling brick tiles or terracing tiles single layer on roof laid dry and pointed in cement mortar all as specified and directed by Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leaping including cutting or uprooting grass on roof complete all as directed by Engr-in-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement with WPC complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete or filling in sunken floor/bottom side of drain complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge. :- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified Manufacturer. Make:- Dr. Fixit/Fosroc/STP Note: (i) The treatment shall be carried out by approved authorised applicator approved by GE as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor (sunken) shall be considered for payment and provn of cement work (except) PCC in sunken filling item 41 is included in quoted rate for this item. (iii) PCC filling in sunken portion will be measured seperately.
Supply & fixing 450mm long mild steel galvanised tubes (GI pipe) (medium grade) of size 40mm bore as in spouts including making holes in RCC and making good with cement mortar (1:1) or PCC (1:2:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for wire brushing and cleaning top surface of tiles or cement concrete and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20kg per sqm as in roof complete all as specified and directed by Engineer-in-Charge.
Material and labour for lime concrete terracing as specified in roof excluding bitumen tack coat complete all as specified in MES Sch Part-I and Part-II and as directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on15mm thick cement mortar in cement mortar (1:6) bedding and joints grouted in cement mortar (1:3) mixed with integral water proofing compound by weight of cement complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 46 here-in-before but except tiles complete all as specified and directed by Engineer-in-charge.
M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs, benching rounded or chamfered on edges complete all as specified & directed by Engineer-in-Charge .
Racking out joints / pointing to brick work in walls or to brick tiles, laid flat, in floors, surface channels, roofs etc complete all as specified and directed by Engineer-in-Charge.
M&L for keyed pointing in cement mortar (1:3) to brick laid flat or brick tile in paving complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each complete all as specified & directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each complete all as specified & directed by Engineer-in- charge.
Taking down shutters not exceeding 1.0 Sqm each complete all as specified & directed by Engineer-in- charge.
Taking down shutters exceeding 1.0 Sqm and not exceeding 2.0 Sqm each complete all as specified & directed by Engineer-in- charge.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and complete conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in- charge.
M&L MS flat iron work 25mm x 3mm conforming to Fe-290 (Gde E-165) as in hold fasts, including preparing surfaces & two coats of coaltar complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel framed work as in grills, grating, railings etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work for water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in hold fast blocks for doors/ windows, bed blocks, splash stone, filling of chowkhats etc including necessary form work complete all as specified and directed by Engineer-in-Charge .
Providing CASEMENT UPVC WINDOW/vent fabricated by approved manufacturer in different size of wall thickness 1.2mm +0.25mm made out of extruded section plain UPVC sections, the window/vent frame made out of rigid UPVC sections meter cut at 4 corners & joint with plastic fution welding with internal reinforce require. The shutter section made out of extruded rigid UPVC with internal reinforced with provision of 5mm glaze wire mesh as per requirement. The window will be fixed to all using 65 x100 mm long MS fasterners at suitable place provided for each vertical and horizontal member etc.complete as per manufacturer's specification and direction of Engineer-in Charge.
S&F fiber Glass Reinforced plastic (FRP) door frame (ISI marked) of three legged of cross -section 90mm X 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness .The laminate door frame moulded with fire retardant grade unsatrated polyester resin and chopped mat (CSM), door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs, the frame shall be covered with fiber glass from all sides. MS stay shall be provided at the bottom to stand by the frame complete all specified and directed by Engineer-in-Charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled doorshutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised type B-21 and fixed complete all as specified and as directed by Engineer-in-charge.
S&F 200mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodised door handles cast type , fixed with steel screws complete as specified & directed by Engineer-in-charge
Taking down wooden shutters only of any description area exceeding 1 sqm and not exceeding 2 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs etc all as specified and as directed by Engineer-in- charge.
S&F 35mm thick, factory made plain framed panelled (three panels) shutters of 2nd class hard wood with lock rail and panel inserts of 9mm thick BWP commercial ply or 12mm thick veneered particle board flat pressed three layered conforming to IS-3097 exterior grade-I type- I duly ISI marked general purpose commercial veneered on both side bonded with (BWR) type phenol formaldeyde synthetic resin-adhesive, the size of rails and styles as per IS-1003 Part-I, Kiln seasoned and chemically pressure treated including one shop coat of pink primer complete all as specified & directed by Engineer-in-Charge Note :- The species of timber shall be Hollock/Bonsum
Supply & fix 35mm thick, factory made glazed and skeleton shutter of 2nd class hard wood open rebated and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8.24 (a) and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsom.
Supply & fixing flush shutter 25mm thick, solid core construction with block board core and plywood face panels, commercial type on both sides as cupboard complete all as specified and as directed by Engineer-in- charge.
Supply and fix 100 mm long mild steel butt hinges cold rolled medium weight, fixed with steel screws complete as specified & directed by Engineer-in-charge .
S&F in 300mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
Supply & fixing 300 mm long aluminum alloy, anodised, sliding door bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- charge.
S&F in 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
M & L for 19/20mm thick block board, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face fixed with screws to timber frame work including 6mm thick teak wood lipping fixed with nails complete all as specified & directed by Engineer-in- charge.
M & L for 2nd class hard wood plain fillets square, recangular or triangular in section wrought fixed on wall with nails having cross sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm complete all as specified and directed by Engineer-in- charge.
M & L continous piano hinges mild steel bright finish or electrogalvanised of 30mm flap width complete all as specified & directed by Engineer-in- charge.
S & F 125mm long Aluminum hasp & staple, safety type, with mild steel hinge pin including bolt to hinge plate fixed with screws complete all as specified and directed by Engineer-in-charge.
S&F 125 mm long aluminium anodised door handles cast type , fixed with steel screws complete as specified & directed by Engineer-in-charge
S&F Stainless steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass 4mm thick ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified & directed by Engineer-in-charge .
S&F figured glass 4.0mm thick pin head type and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F 12 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws including 6mm thick teak wood lipping etc complete all as specified and directed by Engineer-in- charge.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Supply and fixing drapry curtain rod 25mm dia, fancy type, fabricated out of mild steel sheet not less than 20 guage, including brackets and pair of decorated end knobs (finials), stop roller etc, pretreated powder coated natural color complete all as specified & directed by Engineer-in- charge.
S&F in repair brass hat peg set of solid body of 125mm to 175mm (4 legs) fixed with brass chromium plated screws complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet pan padestel pattern white including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and including plastic seat with cover white in colour, bottom recessed with mild steel chromium plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair PVC low level flushing cistern 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and making connection including making good disturbed portion complete all as specified and directed by Engineer-in-Charge.
S&F in repair chromium plated fancy type health faucet with 1mtr tube & hook complete all as specified and directed by Engineer-in-Charge. (Make-Prayag) Model No-DROPLETS -Cat No-BEA-85)
S&F vitreous china wash hand basin white, flat back of size 300x300mm (corner type) including brackets, PVC connection 15mm dia PTMT 450 mm long, 32 mm dia full threaded PTMT waste coupling and 90cm including cutting for and pinning in end of brackets or erecting stand etc and including 15mm dia fancy type chromium plated pillar tap cast copper alloys with capston heads, screwed down with long screwed shanks and fly nut screwed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib tap, fancy type, long body cast copper alloy, chromium plated, with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule & fixed suitable for 15mm bore iron pipe complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
S&F in repair 15mm dia stop valve, cast copper alloy, with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia stop valve, fancy type chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, scrwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. Make- Model No APR - ESS - 101069 Make-JAQUAR)
S&F brass chromium plated shower rose of size 125mm with or without swivel joints including fixing to iron pipe complete all as specified and directed by Engineer-in-charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified & directed by Engineer-in-charge.
S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 500 litres including 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 0.20 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 0.20 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair 20mm dia gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipes having minimum weight 210gms complete all as specified & directed by Engineer-in-Charge
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing complete all as specified and directed by Engineer-in-Charge.
S&F mild steel water tubing of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 105 here-in-before but fixing only (except pipe) old mild steel tubes with new fittings complete all as specified and directed by Engr-in-charge.
S&F mild steel water tubing of size 20mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 107 here-in-before but fixing only (except pipe) old mild steel tubes with new fittings complete all as specified and directed by Engr-in-charge.
Dismantling 100mm bore cast iron drain pipes including fittings jointed in cement mortar and taking out from trenches all as specified & directed by Engineer-in- charge.
Dismantling 75mm bore cast iron drain pipes including fittings jointed in cement mortar and taking out from trenches all as specified & directed by Engineer-in- charge.
S&F 100mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 111 here-in-before but fixing only complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears ,fixed to walls, with cement joints complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 113 here-in-before but fixing only complete all as specified and directed by Engineer-in-charge.
M&L for 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F in repair 100mm bore cast iron branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch with oval access door complete all as specified and directed by Engineer-in- charge.
S&F in repair 75mm bore cast iron branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch with oval access door complete all as specified and directed by Engineer-in- charge.
S&F in repair 75mm dia cast iron sanitary connection, short connections pipe of length upto 300mm complete all as specified and directed by Engineer-in-charge .
S&F in repair 100mm dia cast iron sanitary connection, short connections pipe of length upto 300mm complete all as specified and directed by Engineer-in-charge .
S&F in repair 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer-in-charge .
S&F in repair 100mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer-in-charge .
Taking down eaves gutters and rain water pipe,soil waste and vent pipe with fittings of any size complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls inlcuding mild steel flat iron clamp of required size complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore door type PVC (SWR) bends of any radius complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel sink with draining board made out of 1.00mm thick for kitchen or laboratory with plugs, washers, waste pipe, cast iron cantilever brackets and connecting union to waste pipe; overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge. (Make : Prayag Model No 1128, Blue Star Model No BSSBSD-49, Jayana Model No SBSD-05)
Repair to damaged concrete in RCC Coloumns/Beam/slab/parapet by using micro mortar and concrete in following stages as approved by GE:- (a) Removing the loose/scale falling mortar and concrete from RCC slab and cutting the affected area in geometrical shape. (b) Cleaning the rusted reinforcement and applying rust removal. (c) Inserting addl reinforcement in case the cross sectional area reduction is more than 20 percent. Welding the reinforcement with existing one and supporting adequetly on walls if required with grout. (d) Providing micro mortar and concrete over bond coat of cover the reinforcement and slab surface. (e) Providing adequate formwork and scaffolding if required. (f) Curing the surface. Rust removal, Bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/ Fosroc and STP and work to be got executed from the authorised applicators of material manufacturer company as approved by GE & as directed. Note : (i) Only net affected treated plain area of slab shall be measured & paid. (ii) All precautions shall be taken by the contractor. Any damage to the existing structure shall be responsibilityof the contractor and shall be made good by the contractor.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping, bed plates including necessary form work with plain fair faces, including chamfers, weatherings, throating etc complete with joints to match complete all as specified and directed by Engineer-in-Charge.
M&L for Precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in landing, cover slab for manholes, chullah hood, chajjas, water troughs, mangers, shelves cover to drains and similar articles with plain fair faces including chamferred, weatherings, throating etc and set in cement mortar (1:6) including necessary form work complete all as specified and directed by the Engineer-in-Charge.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement with WPC complete all as specified and directed by Engineer-in-Charge.
M & L for moorum bed to drain pipes, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Alom Poly Extrusions Ltd (ALCORR) (Note : Excavation, Earth work and Moorum bed shall be measured and paid separately)
M & L for cutting into existing manholes for connecting new 150mm internal dia drain pipe, making good pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required complete all as specified and directed by Engineer-in-Charge.
Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the Engineer-in-Charge. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, gusset plates, etc conforming to Gde Fe-410-W (Gde E- 250) quality 'B' complete all as specified & directed by Engineer-in-charge.
S&F 32 mm bore low density polythelene (LDPE) flush pipe of pressure rating 6 Kgf/Sqm cm complete all as specified & directed by Engineer-in-charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down carefully old distribution boards with MCB's by unscrewing from boards complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable drawn in and including concealed PVC regid conduit including provision of 1.2mm thick pressed steel sunken terminal boxes 60mm deep, suitable length and painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch, bell push or one fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 140 here in before, but for one 3 pin socket outlet 5 Amps on same board complete.
All as per Srl item No 140 here in before, but for one 3 pin socket outlet 5 Amps on independent board complete.
All as per Srl item No. 140 above, but for one light point controlled by two Nos, 2 way switches complete all as specified & directed by Engineer-in-Charge.
All as per Srl item No. 140 above, but with multi-stranded copper conductor FRLS PVC sheathed cable of cross sectional area 4 Sqmm including 4 Sqmm PVC insulated solid copper conductor wire as earth continuity to common earth dolly for 5 Pin 15 amp socket outlet on independant board complete all as specified & directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 5 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F socket outlet two-in-one, 2/3 pin, 6 Amp flush type 230 volts AC complete all as specified & directed by Engineer-in- charge.
S&F socket outlet two-in-one, 3 pin, 15 Amp flush type 230 volts AC complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 15 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F switch piano flush type single pole two way 6 Amps, 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Baton integrated LED 1x 18 channel (Integral sleek extruded aluminium LED channel with white acrylic cover ) tube light fitting wall mounted complete with rod, driver and all other accessories including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge. Make : BCLSB 18 WH of Bajaj or equivalent in Havells/CG
S&F PVC Lamp holder, insulated body with back plate etc suitable for and including LED lamp 9 watt complete all as specified and as directed by Engineer-in-Charge.
S & F bell push flush type 5/6 Amps 230 volts complete all as specified and directed by Engineer-in-Charge.
S & F bell AC type 230 volts single pole complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose polycarbonate surface bakelite 65 x 50mm size three terminals complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator flush type suitable for ceiling fan 1200mm/ 1400mm complete all as specified and directed by Engineer-in-Charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 8 way, protection class IP-43 suitable for mounting MCB/MCCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge.
S&F MCB 05 to 32 Amp, 240 volts, single pole with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F MCB 40 Amp, 240 volts, SP & N with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F MCB 63 Amp, 240 volts, SP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F PVC blanking plate one way with internal lock complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fittings 25 watt LED drawn aluminium housing in grey finish with clear acrylic and cast aluminium pipe mounting attachment including fixing to wall/ on pole including fixing arrangement with suitable galvanized iron pipe 25mm boe light grade brackets 2 mtr length bent to shape required including clamps, buts/ bolts/ washers etc connecting with suitable flexible copper wire of size 23/0.0076 testing complete all as specified and directed by Engineer-in-Charge. Makes:- Bajaj Cat Part No. BRLEP 25 W LED WH or equivalent in Crompton/Havells
M& L for in replacement of sub-main wiring with two runs of single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into and including PVC concealed conduit, including one run of 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 Sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F sheet metal enclosure SP & N with 2 pin earth plug and socket with 20 Amps rated MCB suitable for working on 240 volts AC complete all as specified & directed by Engineer-in-Charge.
M&L for taking down exhaust fan 300 mm sweep single phase 240 volt, 50 Hz and refixing the same incl all electrical connection, fastners of required size complete all as specified & directed by Engr-in-charge.
Supplying, laying, jointing and testing and commissioning of 16 sqmm, 4 core XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
Supplying, laying, jointing and testing and commissioning of 16 sqmm, 2 core XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
S&F Vertical MCB DB distribution box 3 phase TPN 4 ways double door as MCCB 125 Amp 16 KA as incommer with bus bar rating 200 Amps vertical type dust and vermin proof complete all as specified and directed by Engineer-in-Charge.
S&F MCB 100 Amp, 240 volts, four pole with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
M & L for repair to door hinges of MS housing of size 0.90m x 0.60m m including necessary welding and painting the panel with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for taking down Hot water heater (Geyser) storage type AC 230 volts of capacity 25 ltrs of ISI mark refixing and after repair including making connectoin and 02 Nos PVC connection complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, for taking out old pipe and laying new pipe, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of GI pipe 40 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge. Note : (i) Excavation & earth work shall be measured and paid separately under respective item of this Schedule.
Supply and fixing cable route indicator made out of pre-cast RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia MS bars of semi circular shape 15cm dia and 10cm thick duly engraved "MES LT Cable" having RCC pillar of size 10cm x 10cm x 60cm embeded 45cm below ground level and 15cm above ground level and painted with two coats of synthetic enamel paint on concrete surfaces above ground level including necessary excavation and earth work complete all as specified and directed by Engineer-in-Charge. Note: Minimum one Kg reinforcement shall be used for this item and cost of the same is deemed to be included in the unit rate quoted for this item.
M&L for point wiring with 1.5 Sqmm, FRLS, single core PVC insulated, unsheathed, multistranded copper conductor cable, with universal colour code drawn in existing steel / PVC conduit / casing in existing sunken pressed steeel terminal boxes, providing 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated, unsheathed, multistranded copper conductor cable as earth wire in green colour and making good the distrubed surfaces in cement mortar (1:3) for light point controlled by one switch complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 178 above, but for one ceiling / exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 178 above, but for bell point controlled by one bell push complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 178 above, but for 3 pin 5 Amp socket outlet on the independent board with other switch, sockets complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 178 above, but for wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 4 Sqmm for 15 Amps power point complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame 40 x 40 x 6mm on top and excavation/ earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe upto earth pit shall be provided in slantling position as included in this item. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,47,075.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 40 & 41(R) (Schedule of Credit) of Tender document
M/s Balvinder Singh Engineer and Contractors
AJAY CONSTRUCTION COMPANY
NATIONAL ENTERPRISES
PAREEK AND COMPANY
KHANNA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .