Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.8 L+₹1.9 L (7.48%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹29.1 L+₹3.2 L (12.3%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.5 L+₹14.6 L (56.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Jun 2023, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP ComplexNear AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2023_MES_595560_1
GE/NRC/8969/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹80,000
Yes
22 Jun 2023
15 May 2023
14 Jun 2023
15 May 2023
12 Jun 2023
29 May 2023
Amount
Taking down/maintenance for parts of geysers of any capacity /make after disconnecting the wire from existing power point and refixing the same after repair of / replacement of heating element, thermostate, geyser assembly, PVC pipe & anchor bolts (if required) complete including providing T-3 core copper conductor cord from power point to geyser input upto 1 mtr length complete all as directed by Engr -in- charge, Notes :- (i) Work shall be carried out at the site on routine basis , (ii) Spares (heating element, thermostate, ARV, NRV, PVC pipe, gasket and anchor bolts will be measured separately)
Taking down and fixing on the site of old & unserviciable geyser after replacement of to verticle/horizontle tank of any Make, capacity 25 to 50 ltr all as specifide and directed .
S& F in replacement of cable PVC insulatd 3 core 2.5 Sqmm with stranded copper conductor 1100Volts grade from socket /switch to geyser.
M&L for repair of geyser inner tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete
Supply and fix in replacement of 20A SP/SPN plug and socket inclosure in sheet steel inclosures without SP/SPN MCB complete all as specified and directed.
S&F in replacement of Geyser water storage tank vertical/horizental type capacity 25 ltr make of metal copper/stainless steel as specified and directed
S&F in replacement of of Geyser water storage tank verticle/horizental type campicity 50 ltr make of metal copper/stainless steel as specified and directed
Taking down and refixing on the site after replacement of of geyser (new generation) of any make and capacity including providing heating element, thermostate, neno lamps, NRV, ARV, gas welding /brazing and any other important part as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge.
Taking down and refixing on the site after replacement of of solar geyser of any make and capacity including providing heating element, thermostate, neno lamps, NRV, ARV, gas welding /brazing and any other important part of solar plate as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Glass wool PF any colour complete all as directed by Engineer-in-Charge
S&F in replacement of heating element tringle type 1500 watt , complete all as specified and directed by Engineer –in-Charge.
S&F in replacement of heating element cup type1500 watt, complete all as specified and directed by Engineer –in-Charge
S&F in replacement of heating element thread type 1500 watt , complete all as specified and directed by Engineer –in-Charge
S&F in replacement of heating element tringle type 2000 watt , complete all as specified and directed by Engineer –in-Charge
S&F in replacement of heating element cup type 2000 watt, complete all as specified and directed by Engineer –in-Charge
S&F in replacement of heating element thread type 2000 watt, complete all as specified and directed by Engineer –in-Charge
S&F in replacement of themostate for geyser, complete all as specified and directed by Engineer –in-Charge
S&F in replacement of neon lamp for geyser yellow /red/green, complete all as specified and as directed by Engineer –in-Charge
S&F in replacement of air realese valve for geyser as specified and as directed
S&F in replacement of Non returned valve 15mm for geyser all specified and as directed
Supply and fixing in replacement of flexi PVC connection armoured type both side brass union type nuts 45/60/90cm length complete all as specified and directed.
S&F in replacement of anchor bolts 75mm long made out of stain less steel complete all as specified and directed
Supply and fixing in replacement of gasket rubber ring of Heater plate of any size geysers.
Supply and fix in replacement of new geyser assembly for any make/model/capacity of geysers including all necessary replacement of required to make it serviceable. complete all as specified and directed by Engr-in-Charge.
Taking down and dismantling of 1200MM ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items ( Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No) and including necessary transportion to workshop, for following sweeps of ceiing fan .
All as per Item No. 25.00 but size 1400MM.
Fixing or hanging only ceiling fan after rewinding fan under item No. 25 above and , connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Taking out defective /burnt winding of air ventilator/exhaust fan of various make of size 225 mm sweep working on 230 to 380 volts single phase /AC supply and Rewinding with supper enamiled new copper wire of apropriate Gauge including warnishing good quality varnish heating and re assembling the fan /testing /transpotation /placment/of connector flexible copper wire size 23/0.0040, 3 core up to one metre/reqd at site complete all as specifiede and directed.
All as Item No 28.00 above but for exhaust fan rewinding of size 250mm sweep
All as Item No 28.00 above but for exhaust fan rewinding of size 380mm sweep
All as Item No 28.00 above but for exhaust fan rewinding of size 450mm sweep
Fixing only exhaust fan after winding fan any height under item No. 28 to 31 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassembling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (i) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (ii) The spares required shall be measured and paid separately in the relevant items).
Takning down/Overhauling exhaust/wall mounted fan of any type and size after disconnecting the conection from exiting ceilling to connector and transpotation to work shop /cleaning externally dismantlling and examining the rotter /stator /bearing/bushing etc for serviciablity /replacement ofing/replacing/defective part subsequntly oiling /greasing/asembling/ testing of propper functoining cheking for sefty/ security and propper locking transporting back to building /site to workshop/hanging /fixing/and connecting /the electrical conection testing of noise free smooth runing etc.all as directed
Taking down of ceiling fan/exhaust fan of any size /sweep after disconecting the wire from existing ceilling rose and refixing the same after cleaning dust ,oiling, greasing & hanging clamps (if required) complete including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engr -in- charge,Notes :- Works will be carried out at the site on routine basis.
Taking down old unserviceable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1200mm sweep size complete all as specified and directed.
Taking down old unserviceable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1400mm sweep size size complete all as specified and directed.
Taking down old unserviceable rusted exhaust fan blades and providing new exhaust fan blades with fixing new screw as apporpriate shape /size suitable for exhaust fan of any make and size of sweep complete all as specified and directed.
Painting of ceiling fan/ 1200/1400 mm sweep/exhaut fan 225 to 450 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
Taking out worn out gun metal bush and supply and fix new gun mettal bush for various make of ceilling fan of size 1200 to 1400 mm sweep complete all as specifide and as directed.
Supply and fix bearing for ceiling fan (Bearing No.6201 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6202 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6203 Z Type).
Supply and fix bearing for ceiling fan (Bearing No.6204 Z Type).
Taking out defective capacitor and supply and fix new capocitor of 2.5 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts , as approved make for various make of ceilling fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 4 MFDas approved make for various make of exhaust fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 6 MFD as approved make for various make of exhaust fan complete all as specified as directed.
Supply only Split pin.
Supply, fixing in replacement and connecting up flexible copper cable twin core of 0.75 Sqmm.
Taking out rusted /defective down rod and supply and fix new down Rod of midium grade GI tubing 15mm bore having hole and threading at ends as per site requirement complete specified all as directed.
Removing broken /cracked Canopy of any make and type and supply and fix new canopy of existing make and size all as directed.
S&F in replacement of Rubber real for fans clamp complete all as per sample
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS.322912.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
metro electrical services
Shree Sai Samarth Enterprises
M/S SVOJAS ELECTROMECH ENTERPRISES
Bidder Name
sapana enterprises
metro electrical services
Shree Sai Samarth Enterprises
M/S SVOJAS ELECTROMECH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .