Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | Accepted-Technical Documents in order |
| 2 | Rejected-Technical | Rejected-Technical Due to No uploading of MOU as per NIT/ Tender |
| 3 | Rejected-Technical H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | Rejected-Technical Due to No uploading of MOU as per NIT/ Tender |
| 4 | Rejected-Technical N A | NEW DELHI | DELHI | 110001 | Rejected-Technical Due to No uploading of MOU as per NIT/ Tender |
| 5 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | Rejected-Technical Due to No uploading of MOU as per NIT/ Tender |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
31 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
MISC REPAIR/REPLACEMENT TO SUMMER APPLIANCES, WINTER APPLIANCES, TOWER ACs AND CONNECTED MISC E/M WORKS UNDER GE (EAST) DELHI CANTT-10
2025_MES_742741_1
GE/DE-145/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Cat c (i)/ Class D
9 documents required · 9 mandatory
₹500
GE (EAST) DELHI CANTT-10
₹96,000
Yes
2 Feb 2026
3 Dec 2025
2 Jan 2026
3 Dec 2025
31 Dec 2025
24 Dec 2025
Each Set
Attending the break down complaint of all nature for window/split AC/tower AC/ cassette AC unit and their electrical wiring from main DBs of any capacity and make them functional and also carry out the required repair on all days including Sunday and holidays complete all as specified and directed. Notes- (i) Adequate resoures shall be deployed by the contractor for attending complaints being an essential services with adequate No of AC mechanics & helpers to attend day to day as per requiremetn and as directed by Engr-in-Charge. (ii) Any parts/ accessories required to be replaced shall be measured and paid separately under respective items of this Schedule/BoQ. (iii) All refrigerator mechanic to be deployed at work should have in possesion of ITI certificate in refrigeration and air conditioning or equivalent trade with at least 03 (Three) years experience in this field. (iv) Complaint should be attended within 2 hrs. (v) If complaint not attended within 2hrs, damage will be done as follows:- (a) For upto 12 hrs @ Rs 500. (b) for more than beyond 12 hrs @ Rs 1000 per 12 hrs.
Notes : (a) All repair/replacement work shall be carried out by authorised technicians duly certified by one of any OEM i.e LG/ Voltas/ Dakin/ Samsung/ Blue Star/ Carrier. (b) Contractor shall upload the valid experience certificate of minimum three AC mechanics issued by OEM, having technical qualification and minimum three years experience in the field of air conditioning and refrigeration alongwith tender documents on e-tender portal while biding. In addition contractor shall submit the hard copy of the same certificate in the office of accepting officer within 05 days of bid submission end date. Non complying of the above, the bid of contractor shall be rejected in tech evaluation.
M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and
Supply only of remote for window/ split type AC any type and any capacity as per existing make/ model at site cpmplete all as specified and directed.
S&F in replacement of PCB suitable for tower type AC of any capacity and model complete all as specified and as directed.
S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ Scroll type, suitable for 1.5 TR window type AC/ Split AC of existing capacity and make complete all as specified and as directed.
S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type, suitable for 3.0 TR tower type AC suitable for 3 phase supply of existing capacity and make complete all as specified and as directed.
Description all as per srl item No 3.00 here-in-before but Tower type split AC of any capacity complete all as specified and as directed.
Supply & fixing in replacement drain pipe PVC medium grade size 25 mm dia including fittings complete all as specified and as directed.
Supply & fixing in replacement drain pipe PVC flexible type 15/20 mm dia including fittings complete all as specified and as directed.
Supply & fixing in replacement running capacitor 50+6 MFD complete all as specified and as directed.
Supply & fixing in replacement indoor unit swing motor, suitable for split AC of existing capacity and model complete all as specified and as directed.
S&F in replacement of PCB, suitable for non-inverter type, split AC/ window AC of any capacity and existing make/ model complete all as specified and as directed.
S&F in repair Condenser Coil, made out of copper tube & Aluminium fins, suitable for Outdoor Unit of Tower type AC of 3.0/4.0/4.5 TR capacity of existing make and models complete all as specified and as directed.
Supply & fixing in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 2.5 sqmm complete all as specified and as directed.
Supply & fixing in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 4.0 sqmm complete all as specified and as directed.
Supply & fixing in replacement flexible copper conductor cable 4.0 Sqmm, 4 core, PVC insulated & PVC sheathed complete all as specified and directed.
Supply and charging R-22/R-290/R-404a refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply and charging R-410a refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply and charging R-32 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply & fixing in replacement Motor (copper wound) suitable for window type AC of existing capacity, double shaft complete all as specified & as directed.
Supply & fixing in replacement copper pipe 1/2” dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
Supply & fixing in replacement copper pipe 1/4" dia, wall thickness 0.030 mm including insulation complete all as specified & as directed.
M&L for shifting of Split type AC of any capacity, any type/make, with stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installing the same to new location using existing copper piping for suction and delivery with insulation, drain pipe and re-fixing arrangement i. e. lifting angle, fasteners, nut bolt, washer etc, testing & commissioning complete all as specified and directed. Notes: (i) The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) The additional copper piping & Gas charging, if required shall be measured and paid separately under respective items of this Schedule.
S&F in replacement of indoor unit complete set, suitable for 1.5 TR split AC, consisting of blower motor, blower, wiring kit complete with display, electronic card with remote assembly, evaporative /cooling coil, remoting system, and plastic housing with bracket frame suitable for R-32/ R-410 gases complete all as specified and as directed. Make : HItachi/ Camipro/ Carrier
S&F in replacement of indoor AC unit back plate for split type AC complete all as specified and directed.
S&F in replacement of Pin/service/ charging valve of size 3/8", 5/8'' for window AC and Split AC of existing model complete all as specified and as directed.
M&L for sleeve foam Protection with aluminium coating on top of insulation suitable for Split type Air Conditioner 1.5/2.0 TR for both suction and discharge line fixed as in repair complete all as specified and directed.
M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L in repair sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
S & F in replacement of MCB, SPN, 240 Volts, 32 to 40 Amps, C curve type complete all as specified and as directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tender145.pdf
Tender Documents • 1.26 MB
BOQ_831724.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .