Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.2 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹1.3 Cr+₹47.5 L (55.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹80 L
EMD Value
₹80,000
Closing Date
19 Oct 2023, 5:00 pmClosed
Superintending Engineer
EDC, Ayodhya
Maintaning of 11 KV Feeder line ans Interpoling of Different Places, Incrising Capacity of Transformer and Cable Laying Under Electricity Distribution Division-IInd, Ayodhya
2023_MVVNL_849051_1
90 H(F)(W)/2023-24
Open Tender
Electrical Works
Item Wise
90 days
Ayodhya
As Per TenderSpecifcation
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EDC
₹80,000
31 Oct 2023
11 Oct 2023
20 Oct 2023
11 Oct 2023
19 Oct 2023
11 Oct 2023
Amount
Part - A ( Material) Following Material Supplied by the Contractor:-
Supply of G.I. Pipe 6'' Dia
Alluminum Lug
LT Clamp
LT Shackle Insulator
11 KV X- Arm Holding Clamp
11 KV F Clamp for PCC Pole
Holding Clamp Top & Dropper Channel
Fuse Set Unit Clamp
Different Size of Clamp for Supporting (Top, tEE off, Dropper GI Pipe ETC) Rs. 213
Nut & Bolt
Carriage including loading,unloading & Proper stacking of following Stock materials from store/departmental store to Dump site distance 0 to 20 Kms. (distance approx)
PCC Pole 8.5 Mtr. Long
ST Pole 11 Mtr. Long
11 KV XLPE Cable 3x70 sqmm
11 KV XLPE Cable 3x120 sqmm
11 KV XLPE Cable 3x185 sqmm
11 KV outdoor Cable Jointing kit 3x70 sqmm
11 KV outdoor Cable Jointing kit 3x120 sqmm
11 KV outdoor Cable Jointing kit 3x185 sqmm
11 KV Staight Through Cable Jointing kit 3x120 sqmm
Three Phase DO Fuse Set Unit
AB Cable (3x120+1x95+1x16)
ACSR Weasel Conductor
ACSR Rabbit Conductor
L T PVC Cable 1x400 sqmm
11 KV Outgoing Pannel CTR (200/100/5A)
T/F 63 KVA
T/F 100 KVA
T/F 250 KVA
T/F 400 KVA
Other matching Materials
Dragging of PCC/ST Pole from dump site to pit site
Fabrication and Errection of Double Pole Support on PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Fabrication and Errection of Single Pole Support on PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Stringing, Sagging, Binding and jumpering of ACSR Weasel Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of ACSR Rabbit Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable 3x120 Conductor as per RESSPO Norms
Grouting and Binding of Stay with in 1:4:8 ratio with cement, sand and brick ballast including cost of all grouting materials as per RESSPO Norms
Earthing of Poles as per RESPO Norms
Mounting of 63 KVA Transformer as per RESSPO Norms.
Mounting of 100 KVA Transformer as per RESSPO Norms.
Mounting of 250 KVA Transformer as per RESSPO Norms.
Mounting of 400 KVA Transformer as per RESSPO Norms.
Construction of Plinth of Transformer Size 2x2x2.5 Mtr including excavation of foundation, base concreting of 1:6:12 (Cement mortar of Ratio 1:4 foundation, CC in 1:4:8 ratio (Cement fine sand and brick ballast ) and RCC work with ratio 1:2:4 Cement, Coarse sand and Stone Grit of 20 mm gause as per RESSPO norms
Fencing of Transformer Plinth with the help of wire mesh/Barbed wire after grouting proper size of angle as per RESSPO Norms. Inclusive of all material such as Wiremesh/Barbed Wire, Angle Flats, Nut Bolts etc.
Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm dia 20 mtr. Long from ground upto the water lavel it will be connected to the G.S. Strip for T/F nutral connection the earth strip will be welded to the G.I. pipe the work also included top cap and clamps for pouring water the cost of all material will all labour and T n P etc. complete in all respect . (all the material will be supplied by the contractor.)
Laying of underground 11 KV 3x70 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Laying of underground 11 KV 3x120 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Laying of underground 11 KV 3x185 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x70/120/185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Staight Through end Termination suitable for 11 KV XLPE cable 3x120 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Four Wheel Trolly Complete for Transformerr
Installation of 11 KV Outgoing Pannel CTR (200/100/5A)
Fixing of Three Phase DO Fuse Set Unit
Railway Crossing Permission Fee
Rect. Old and Used Scrap Conductor from site to Store Center
Rect. Back 25 KVA Transformer
Rect. Back 63 KVA Transformer
Rect. Back 100 KVA Transformer
M/S R.G. TRADERS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .