Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.4 L+₹42,873.65 (1.43%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹30.9 L+₹92,830 (3.10%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.9 L+₹1.9 L (6.42%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.7 L+₹2.7 L (8.87%)Rejected-Finance 369 KRISHNA BHAVAN DHARMSALA ROAD CINEMA CHURAHA HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹38.3 L
EMD Value
₹76,500
Closing Date
14 Oct 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPL REPAIR FOR CONVERSION OF OVERHEAD CONDUCTOR WITH UNDER GROUND CABLE INCLUDING CONNECTED ITEMS AT HUDSON LINE AND SINDHU MARG UNDER GE E/M LUCKNOW
2024_MES_674919_1
GE/EM/LKO/EXT(ELECT)/T-67 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹76,500
Yes
14 Nov 2024
17 Sept 2024
16 Oct 2024
17 Sept 2024
14 Oct 2024
1 Oct 2024
Amount
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Dismantling of GI wire any type and any size complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
Dismantling of insulators any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of stay assembly any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of steel poles of any type any size including GI pipe for cable protection, service cable / underground cable etc complete all as specified and as directed by Engineer -in-charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L for laying of well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
All as per srl item No 11 here-in-before but using old bricks obtained under srl item No 7 here in before.
M&L for demolition /cutting of road / path / hardstading / concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads / path / hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note- Excavation, earth works, and sand cushioning, protection bricks / tiles / blocks and pipe shall be measured and paid seprately.
All as per item No 19 above but LT UG cable of size 25 Sqmm 4 core.
All as per item No 19 above but LT UG cable of size 35 Sqmm 3.5 core.
All as per item No 19 above but LT UG cable of size 50 Sqmm 3.5 core.
All as per item No 19 above but LT UG cable of size 70 Sqmm 3.5 core.
All as per item No 19 above but LT UG cable of size 95 Sqmm 3.5 core.
All as per item No 19 above but LT UG cable of size 120 Sqmm 3.5 core.
All as per item No 19 above but LT UG cable of size 185 Sqmm 3.5 core.
M&L for earth continuity conductor or main earthing lead laying to treanches & fixed to pole 4 mm dia galvanised iron wire complete all as directed by Engr-in-charge.
Supply & fix in replacement automatic street light timer panel 12 KW /40 Amp switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of ingress three phase 8 KW lightening load capacity including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
Supply, installing, testing and commissioning factory made, CPRI approved, confirming to IS 5039, LT Panel board (Dimention of Cubical / enclosure not less than 1200 mm x 900 mm x 500 mm), cubical compartmentalized, out door type, double door, plateform mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of 3.15 mm thick CRCA sheet, inner shell made of 2.0 mm thick CRCA sheet, 50 x 50 x 6 mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm duly, overall powder coated, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 400 Amps, 50 Hz,415 Volts, 36 KA, with Adjustable thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA Adjustable thermal magnetic release - 01 Nos (iii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 27 KA Adjustable thermal magnetic release - 01 Nos (iv) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 27 KA Adjustable thermal magnetic release - 03 Nos
(c)- Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
All as per item No 29 above but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with Adj thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 320/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA Adj thermal magnetic release - 01 Nos (ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA Adj thermal magnetic release - 01 Nos (iii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 27 KA Adj thermal magnetic release - 05 Nos
All as per item No 29 above but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with Adj thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 36 KA Adj thermal magnetic release - 01 Nos (ii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA Adj thermal magnetic release - 04 Nos
M&L for out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
M&L out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 125 Amps 25 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed, copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333 x 233 x 120 mm, inside dimention 300 x 200 x 105mm, single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing / painting of danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Material and labour for renewal earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Supply and fixing in replacement MCCB FP 125 Amps, 25 kA, 415 Volt AC, 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.
abhinav enterprises (BID ID -3138532)
M I & CO. (BID ID -3138099)
Diamond Electric Co. (BID ID -3137642)
Sai Solar Power (BID ID -3128215)
OMVIN ENTERPRISES LLP (BID ID -3131465)
Unnati Engineers (BID ID -3131006)
Ajanta Associates (BID ID -3131306)
GYAN ENTERPRISES (BID ID -3130431)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .