Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹46.9 L+₹3.5 L (8.12%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹47.4 L+₹4.1 L (9.40%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹48.1 L+₹4.7 L (10.8%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹48.7 L+₹5.3 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
7 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
PROVISION OF GREASE TRAP ALONG WITH ITS ALLIED WORKS AND CERTAIN E/M SANCTIONED WORKS AT AF STATION CHABUA UNDER GE(AF) CHABUA
2023_MES_628480_1
532/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹91,000
Yes
12 Jan 2024
16 Nov 2023
9 Dec 2023
16 Nov 2023
7 Dec 2023
30 Nov 2023
16 Nov 2023 - 23 Nov 2023
Amount
SCH 'A' PART-I
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
Demolition of unreinforced concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC (1:3:6) type C-2, (using 40 mm graded aggregates) 75 mm thick as in levelling course / sub base complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick screed bed in CM (1:4) complete all as specified and directed.
Surface excavation nexc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavating over areas not exceeding 1.50m deep and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for precast reinforced cement concrete in baffle walls or manhole covers type B1, 1:2:4 (using 20mm graded stone aggregates) including necessary metal lathing or TMT bar having weight not less than 2% by volume of RCC inside and use and waste of formwork kept in position in brick masonry and set in cement mortar 1:3 complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 for internal/external wall surfaces and finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (20 mm graded stone aggregate) as in copings / bearing course over brick walls etc and like complete all as specified and directed.
M&L for 50mm thick cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in floor of septic tank finishing surface even and smooth without using extra cement complete all as specified and directed.
S&F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc of weight exc 5 Kg in each complete all as specified and directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290, Gde-E-165 complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coat of cement base paint, white or tinted over one coat of primer complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (40mm graded stone aggregates) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Excavating in trenches, nexc 1.5 m wide and nexc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sqm on plan and nexc 1.5 m in depth and getting out complete all as specified and directed.
M&L for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed complete all as specified and directed.
M&L for cement concrete type D-2 1:4:8 (using 40mm graded stone aggregates) bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in trenches for 150mm dia of pipe complete all as specified and directed.
M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified and directed.
SCH 'A' PART-II
Taking down Old burnt /Unserviceable LT UG Cable of size 150 sqmm after proper disconnecting of electric connection all as specified and directed.
Taking down Old burnt /Unserviceable LT UG Cable of size 70 sqmm after proper disconnecting of electric connection all as specified and directed.
Taking down Old burnt /Unserviceable LT UG Cable of size 16/ 25 sqmm after proper disconnecting of electric connection all as specified and directed at site.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs complete of size 300 Sqmm nominal cross section 3.5 core complete all as specified and as directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs complete of size 120 Sqmm nominal cross section 3.5 core complete all as specified and as directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs complete of size 35 Sqmm nominal cross section 3.5 core complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415 volt 250 Amps with breaking capacity 35 KA, 50 Hz complete all as specified and directed.
Supply and fix steel tubes, galvanised, light grade, ISI marked 40 mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 50 mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreting with PCC 1:3:6 to match with the adjacent surfaces complete all as specified and directed.
Material and labour for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) up to 180mm thickness complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
Materials and labour for brick work with Sub Class 'B' bricks well burnt laid breadth wise along the length or cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs / Main Switches, etc and making good to disturbed surface all as specified and directed.
Taking down serviceable MCB of any size/any type from existing MCB SPN 4 way DB after disconnection of electric connection carefully complete all as specified and directed.
Re-fixing of serviceable 6 to 32 Amps MCB SP obtained from item Sl No. 39 above with connection complete all as specified and directed.
Re-fixing of serviceable 32 Amps MCB SPN obtained from item Sl No. 39 above with connection complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Supply and draw submain wiring with two single core 6 sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn through in and including PVC concealed conduit pipe 25mm dia medium grade ISI marked including all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete all as specified and directed.
M&L Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole 20 amps MCB including cutting, chasses and making good disturbed surface to match with existing finish with plaster/distemper complete all as specified and directed.
M&L for point wiring with 4 Sqmm single core PVC insulated FRLS unsheathed copper multi stranded conductor in concealed PVC conduit of size 20mm dia medium grade ISI marked including all necessary fittings including 4 Sqmm single core PVC insulated FRLS unsheathed copper multi stranded conductor as earth wire to common earth dolly for connection including cutting, chasses and making good disturbed surface to match with existing finish with plaster/distemper for AC socket complete all as specified and directed.
M&L for earthing complete with galvanized mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole or wall with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth pit to top of earth plate electrode including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel, CI frame etc including taking down old unsv earthing complete all as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:2:4 type B-0, using 12.5 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply & Fix Factory made, distribution boards, sheet metal enclosure VTPN, 4 Ways, 415 Volts double door type, protection class (IP-43) suitable for mounting MCCBs, DBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar complete all as specified and as directed.
Supply and fixing MCBs Distribution board, sheet metal enclosure, SPN 240 Volts, 08 ways with 200 Amps rated bus bar, double door for MCBs, with IP 43 protection, complete all as specified and directed.
Supply and fixing MCCB, 4 Pole, 40 Amps, with breaking capacity 16KA, Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM), Ics=100% Icu, AC 415 volt, 50 HZ complete all as specified and as directed.
Supply and fix MCB, SPN 40 Amp 10KA braking capacity, 'C' curve 230/240 volt AC complete all as specified and as directed.
Supply and fix MCB, SP 25 Amp 10KA braking capacity, 'C' curve 230/240 volt AC complete all as specified and as directed.
Supply and fixing blanking plate suitable for MCB DB TPN/SPN complete all as specified and as directed.
M/s Sashi Enterprise
M/S RK Trading
M/s Pramillabh Construction
M/S K S Enterprise
M/S S. P. ENTERPRISE
FREEZCON
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .