Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC KHUKURANI MANDAL | MEDINIPUR EAST | WEST BENGAL | 721130 | ₹4.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.8 LRejected-Finance 869 0 NIVEDITA PALLY NAIHATI NORTH 24 PARGANAS | NAIHATI | NORTH 24 PARGANAS | WEST BENGAL | 743165 | ₹4.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹5.2 LRejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹5.2 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | KAR ENTERPRISE L1 | M/S R. K. ENTERPRISE L3 | DEPALI CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14] | ||||||
| 1.01 | 6 Way Enclosure [Make: Legrand Enclosure (607716) or equivalent model of L&T/ABB/Siemens/Crabtree as approved by E.I.C] | 1 | Each | 3,208 ₹3,208 | 3,200 ₹3,200 | 3,504 ₹3,504 |
| 2.00Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. | ||||||
| 2.01 | 2+12 way Enclosure [Make: Legrand Enclosure (607712) or equivalent model of L&T/ABB/Siemens/Crabtree as approved by E.I.C] [D-9/13] | 2 | nos | 1,572 ₹3,144 | 1,600 ₹3,200 | 1,757 ₹3,514 |
| 3.00Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6] | ||||||
| 3.01 | 40 Amp DP Isolator | 2 | Nos | 325 ₹650 | 320 ₹640 | 349 ₹698 |
| 3.02 | 63 Amp FP Isolator | 1 | Nos | 810 ₹810 | 820 ₹820 | 845 ₹845 |
| 4.00Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7] | ||||||
| 4.01 | (a) 6-32 Amps SP MCB | 42 | nos | 175 ₹7,350 | 180 ₹7,560 | 190 ₹7,980 |
| 5.00Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan /call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] | ||||||
Tender Value
Refer Docs
EMD Value
₹9,700
Closing Date
18 Feb 2026, 1:00 pmClosed
AE/KRESD/PWDte
Office of The Assistant Engineer, Kolkata Raj Bhavan Electrical Sub Division, P.W.Dte., 2 Larkin Lane, Kolkata-700062
Special Repairing and replacement of old electrical installation work at Sagar Kaksh(erstwhile Wellesley Suite) at Second Floor Main Building of Kolkata Raj Bhavan in parity with related Civil renovation works.
2026_WBPWD_1000382_1
WBPWD/AE-KRESD/NIQ-49/2025-26
Open Tender
ELECTRICAL WORKS M/R
45 days
Kolkata Raj Bhavan
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,700
15 May 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
18 Feb 2026
6 Feb 2026
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14]
6 Way Enclosure [Make: Legrand Enclosure (607716) or equivalent model of L&T/ABB/Siemens/Crabtree as approved by E.I.C]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+12 way Enclosure [Make: Legrand Enclosure (607712) or equivalent model of L&T/ABB/Siemens/Crabtree as approved by E.I.C] [D-9/13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6]
40 Amp DP Isolator
63 Amp FP Isolator
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7]
(a) 6-32 Amps SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan /call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
i) Average run 12 mtr [E-25/4(g)]
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.
25 mm dia 3 mm thick polythene pipe without earth continuity wire [E-2/4(a)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm) [E-9/C1(b)]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [E-9/C1(s)]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [E-9/C1(v)]
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9/C1(g1)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
2.5sqmm [F-5/9(i)]
4 sqmm [F-5/9(ii)]
10 sqmm [F-5/9(ii)]
16 sqmm [F-5/9(ii)]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
4 Module [E-17/F1(a)]
6 Module [E-17/F1(b)]
8 Module [E-17/F1(c)]
2 Row 12 Module [E-17/F1(e)]
2 Row 18 Module [E-17/F1(f)]
Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(a)]
Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)]
Supply & Fixing 240 V, 6 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)]
Supply & Fixing 240 V,16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
Supply & Fixing 240 V, 25A Modular switch type SP MCB (C-Curve) ((Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[E-19/19(a)]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [D-13/22]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [E-18/10]
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. [C-3/21(b)]
Supply & fixing of Blank Plate for modular box
Supply and Fixing of 10/12W LED Mirror light fitting necessary connection & necessary arrangement for fixing the same as per direction of EIC. (Philips, Model No. 31403 (Muziris) or equivalent model of wipro/Jaquar/Havells/ Bajaj/CG as approved by EIC)
Supply and Fixing of 3/7W LED Bedside light fitting necessary connection & necessary arrangement for fixing the same as per direction of EIC. (Philips, Model No. 48042 or equivalent model of wipro/Jaquar/Havells/ Bajaj/CG as approved by EIC)
Disconnection & dismantling existing old Electrical installation, Switch-board, wiring, Ceiling fans, Electrical fitting/fixtures etc. with owns tools & takles incl. mending good damages as per GS and clearing/removing from the site as per direction of EIC
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_2450947.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid