Tender Value
₹3.5 L
EMD Value
₹7,000
Closing Date
11 Feb 2023, 6:00 pmClosed
AGE I CG
Noida
PROVN OF UG CABLE FOR STANDBY SUPPLY TO DSC BLOCK AND GARDEN LIGHT IN FRONT OF DSC BLOCK AT SECTOR 62 NOIDA UNDER AGE (I) CG NOIDA.
2023_MES_574661_1
AGE I CGN 39 22 23
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Noida
b (i)
7 documents required · 7 mandatory
₹300
AGE I CG
₹7,000
30 Aug 2023
13 Jan 2023
13 Feb 2023
13 Jan 2023
11 Feb 2023
28 Jan 2023
Amount
Supply, laying and testing cable XLPE insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core complete all as specified and directed.
Excavation in trenches not exc. 1.5 m in depth and not exc. 1.5 m wide for taking out or laying PVC cable/ GI pipe of any size in soft/loose soil complete all as specified and directed.
Material and labour for sand cushioning in layer not exc. 25 cm thick spreading out, levelling complete all as specified and directed.
Supplying and laying bricks,common burnt clay building bricks, sub-class ‘B’ designation 75 all as per specified and directed.
Returning, filling in trenches including spreading levelling, watering and well ramming in layers n.exc. 25 cm thick in soft/loose soil complete all as specified and directed
Removing of surplus soil/excavated material to a distance not exc. 50 m away from the starting point and depositing where directed at al level not exc. 1.5 m above thestarting point complete all as specified and directed.
Supply and fixing of Galvanised steel tubes, 40 mm bore, light grade passing through electric cable for crossing road, drain or vertical support to wall or protection for cable complete as specified and directed by Engr-in-charge complete.
Supply and fixing LED bollard light fitting 10 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make : BAMBOOBLS8WLED830PSYMTOPC of make Havells or equivalent of make Baja/Polycab
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure.
M&L for PCC (1:2:4 ) type B1 using 20mm graded stone aggregate for coping of poles complete all as specified and directed.
Supply, laying, jointing, testing and commissioning LT underground cables, of size 35 Sqmm 3.5 Core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed.
Supply and fixing of Galvanised steel tubes, 50 mm bore, light grade passing through electric cable for crossing road, drain or vertical support to wall or protection for cable complete as specified and directed by Engr-in-charge complete.
S & F Double door sheet metal enclosures factory made Tripple pole and neutral DBs 4 way, 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 A Copper Busbar, with neutral bar, earthbar and cable ties for cable management, fully shrouded neutral bars, prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent in Simens/ Hager/ L & T
MCB Single Pole of 240 volts 5-32 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4085-87 to 90,92,93,94,95 or equivalent in Hager/ L & T
MCB Single pole & Neutral 240 volts, 40 -63 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4086-17 to 20 or equivalent in Simens/ L & T
MCB Triple pole & Neutral 415 Volts ,40 -63 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4086-81 to 83 or equivalent in Simens/ Hager/ L & T
GLIBS CONSTRUCTION
AARYANS GLOBAL INDIA
M/S BEE ESS ENTERPRISES
BLUE HILL ELECTRICAL AND ELECTRONICS
DP COMPLEX
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .