| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAdmitted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Admitted-Finance | |
| 2 | L2₹47.5 L+₹60,480 (1.29%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹48.0 L+₹1.1 L (2.24%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹48.9 L+₹2.0 L (4.22%)Admitted-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Jawandha Enterprises L4 | R D Bansal L1 | SHIVAM ENGINEERS & FABRICATORS L3 | m/s k.k. construction co. L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed by the Engineer-in-Charge. | 300 | Per point | 7 ₹2,100 | 10 ₹3,000 | 5 ₹1,500 Lowest | 20 ₹6,000 |
| 2.00Material and labour Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLSH, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 in existing PVC conduit etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 12 modules with inner and outer modular cover plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and as directed by the Engineer-in-Charge.for the following: - Note:- (i) Modular GI metal flush/sunken Box along with modular base/front cover plate are deemed to be included in the quoted rate of this item. (ii) Only switches,sockets and fan regulators shall be measured and paid separately. | |||||||
| 2.01 | One light/fan/exhaust fan/callbell controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. | 30 | Per Point | 400 ₹12,000 | 320 ₹9,600 Lowest | 350 ₹10,500 | 400 ₹12,000 |
| 2.02 | One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge. | 10 | Per Point | 150 ₹1,500 Lowest | 150 ₹1,500 Lowest | 250 ₹2,500 | 200 ₹2,000 |
| 2.03 | One 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 15 | Per Point | 400 ₹6,000 | 320 ₹4,800 Lowest | 350 ₹5,250 | 400 ₹6,000 |
| 3.00 | All as per item No. 2 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 15 | Per point | 650 ₹9,750 | 420 ₹6,300 Lowest | 450 ₹6,750 | 800 ₹12,000 |
| 4.00Material and labour for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLSH, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 ,marked in and including heavy duty PVC concealed conduit medium grade ISI marked 20 mm dia with all its fittings,PVC junction boxes etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 18 modules with inner and outer modular cover plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and as directed by the Engineer-in-Charge. for the following: - Note:- (i) Cutting/chasing of wall etc. deemed to be included in quoted rate of this item. (ii) Modular GI metalflush/sunken Box along with modular base/front cover plate are deemed to be included in quoted rate of this item (iii) Only switches,sockets and fan regulators shall be measured and paid separately | |||||||
| 4.01 | One light/fan/exhaust fan/callbell controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. | 100 | Per Point | 400 ₹40,000 | 320 ₹32,000 Lowest | 350 ₹35,000 | 410 ₹41,000 |
| 4.02 | One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge. | 30 | Per Point | 150 ₹4,500 Lowest | 150 ₹4,500 Lowest | 250 ₹7,500 | 250 ₹7,500 |
| 4.03 | One 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 50 | Per Point | 400 ₹20,000 | 320 ₹16,000 Lowest | 350 ₹17,500 | 410 ₹20,500 |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
12 Sept 2026, 6:00 pmClosed
CWE Patiala
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact - 01712200082
COMPREHENSIVE REPAIR TO CERTAIN MD and OTM ACCN AT NABHA UNDER GE (S) PATIALA
2026_MES_783356_1
CWE/PAT/T-45/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (South) Patiala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹1.1 L
18 Sept 2026
8 Aug 2026
14 Sept 2026
8 Aug 2026
12 Sept 2026
29 Aug 2026
8 Aug 2026 - 13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed by the Engineer-in-Charge. | - | Per point | 1.25 | - |
| 2Material and labour Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLSH, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 in existing PVC conduit etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 12 modules with inner and outer modular cover plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and as directed by the Engineer-in-Charge.for the following: - Note:- (i) Modular GI metal flush/sunken Box along with modular base/front cover plate are deemed to be included in the quoted rate of this item. (ii) Only switches,sockets and fan regulators shall be measured and paid separately. | |||||
| 2.01 | One light/fan/exhaust fan/callbell controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. | 30 | Per Point | - | - |
| 2.02 | One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge. | 10 | Per Point | 100 | ₹1,000 |
| 2.03 | One 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 15 | Per Point | 53 | ₹795 |
| 3 | All as per item No. 2 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 15 | Per point | 10 | ₹150 |
| 4Material and labour for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLSH, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 ,marked in and including heavy duty PVC concealed conduit medium grade ISI marked 20 mm dia with all its fittings,PVC junction boxes etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 18 modules with inner and outer modular cover plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and as directed by the Engineer-in-Charge. for the following: - Note:- (i) Cutting/chasing of wall etc. deemed to be included in quoted rate of this item. (ii) Modular GI metalflush/sunken Box along with modular base/front cover plate are deemed to be included in quoted rate of this item (iii) Only switches,sockets and fan regulators shall be measured and paid separately | |||||
| 4.01 | One light/fan/exhaust fan/callbell controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. | 100 | Per Point | 22 | ₹2,200 |
| 4.02 | One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge. | 30 | Per Point | - | - |
| 4.03 | One 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. | 50 | Per Point | 10 | ₹500 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
tender45.pdf
Tender Documents • 0.96 MB
BOQ_877775.xls
BOQ • 2.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .