Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.7 LAccepted-AOC | ₹97.7 L Quoted ₹99.9 L | L1 | Accepted-AOC Accepted being lowest quoted tenderer |
| 2 | L2₹1.1 CrRejected-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.1 Cr | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| 3 | L3₹1.2 CrRejected-AOC 28 A 4A DHARAMVIL MARG SULEM SARAI PRAYAGRAJ PIN 211011 UP | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹1.2 Cr | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| 4 | L4₹1.2 CrRejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹1.2 Cr | L4 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| 5 | L5₹1.2 CrRejected-AOC | ₹1.2 Cr | L5 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| Sl No | Description | Qty | Unit | M/S MALHOTRA ENGINEERING WORKS L1 | Amit Engineering L5 | SATISH AND CO L4 | GUPTA ENGINEERING WORKS L6 | GEPS PROJECTS L2 | M/S Amar Enterprises L3 | BRIJ MOHAN LAL AND CO. L7 | R.K.ASSOCIATES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing and commissioning of outdoor type, floor mounted metal clad, 11 KV VCB Panel (RMU) with 6 Nos VCB’s (02 Nos incoming + 04 Nos outgoing), totally enclosed and fully interlocked horizontal draw out, horizontal / vertical isolation type breaker as per IS 131148, as amended up to date and addition specification, having capacities mentioned below, single break, trip free mechanism, manually charged and auto, manually closing breakers suitable for use on 11 KV 3 Phase, 50Hz, AC Supply with short circuit fault level of 350 MVA internal Arc 21KA/1-Sec, short circuit with stand current 26.3KV/3 Sec complete with self-contained fully interlocked, rack in and rack out mechanism, Air insulated but in capsulated copper bus bar of 630AMP capacity, breaker featured with mechanical on /off indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 Nos + 4 NC and equipped with following switch gears and accessories including connections suitable for 3 x 95/12/150Sqmm XLPE 11 KV Cable (Cable entry from bottom), end terminal head shrinkable jointing material etc as required. (Cost of end termination is not included in this items).
(a) Incoming :2Nos 630 AMP VCB.
(i) 2 Nos: 11 KV/110 Volt PT Class 0.5 accuracy and 100 VA burden and protection and fuses/MCB for HT metring up to 12KV on incomer.
(ii) 2 Nos: Digital load manage with built in selector switch.
(iii) 2 Nos : Microprocessor based numerical relay with O/L,E/F and S/C Protection.
(iv) 2 Nos: Set of Dual core Dual ratio 3CT’s 100/50/1+1A Class 1 of 2.5 VA Burden and accuracy class -0.5 for metering and class 5P10 for protection. | 2 | Each | 21,50,000 ₹43 L | 25,76,000 ₹51.5 L | 23,75,000 ₹47.5 L | 25,90,000 ₹51.8 L | 23,50,000 ₹47 L | 21,95,000 ₹43.9 L | 26,01,000 ₹52.0 L | 23,50,000 ₹47 L |
| 1.01(b) Out going- 3 Nos 630 AMP VCB. (i) 3 Nos : Digital multifunction meter for measuring HT Voltage up to 12 KV, current, power factor KVA, KVAh, KW, KWh, Energy with suitable CT’s & MCB,s for protection. (ii) 3 Seal of duel core dual ratio 3 nos CTs 150/50/5/5A of 15 VA burden and accuracy class 1.0 for metering and class 5P10 for protection. (c) Power Pack. Power pack with 220 VAC Input and 24 VDC continues output suitable for closing / tripping / indication of 4 Nos HT Panel board with 2 Nos 12 V Each AMF Batteries of 100 AH Capacity, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of ammeter and voltmeter including connection with 2.5 Sqmm FRLS insulated copper conductor cable etc as required. (d) CFL Illumination in each compartment. (e) Space heater for each compartment. (f) 3 Phase indictor for each compartment. (g) Suitable connection for measuring and protection device with indication. (h) Necessary interlocking arrangement for safety and operation. (j) Operation remote handle for switches are charging spring and test arrangement. (k) Suitable protection as per manufacturing recommendation with PCC 1:4:8 B1 using 20mm aggregate for foundation. (l) Thickness 3mm internal Arc 21KV for 1 Sec. (m) Short circuit with stand current – 26.3 KV for 3 Sec. | |||||||||||
| 1.02(n) Bus Connected PT Unit-01 No for metering consisting of following :- (i) Type M : Air insulated metering module 12 KV, 630A 20 KA for 3 sec. (ii) Three phase transformers of the ratio 11 KV/1.732/110 V/1.732.25 VA Class 1.0 with HT fuses on primary side and MCB on secondary side. (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVRA (iv) 1 CFL illumination. (v) 1 Space heater with thermostate. (vi) 1 RYB phase indicator (vii) 1 Cable support busbar, stand for 3 way unit, 1 manometer & 1 perating handle. (viii) 1 Set bushing for external bushbar connection along with bushbar cover & sleeved bushbars for coupling. (ix) 2x12 V Battery with battery charger of suitable burden for motor operation. Input 230 V AC & output 24 V DC. (o) Capacitive voltage indicator fixed type VPIS 9-15KV. (p) necessary interlocking arrangement for sefty and operation. (q) One No operating handle for manual operation. (r) One No Mono meter. (s) Safety interlock shall be provided as per relevant IEC/IS standard and manufactures directions. (t) Safety interlocks shall be provided as relevand IEC/IS standard and manufactures directions. (u) Above switchgear shall confirm to all relevant IEC/IS standard. (v) Manual operation of vaccum circuit breaker should be possible without dismantling the motor from RMU. the motor should be fitted in such a way that it should not be outside from covers of RMU. Make:- Schneider/ABB/Siemens | |||||||||||
| 2.00 | Supplying, installation, testing and commissioning of outdoor type, floor mounted metal clad, 11 KV VCB Panel (RMU) with 5Nos VCB’s (02 Nos incoming + 03Nos outgoing), totally enclosed and fully interlocked horizontal draw out, horizontal / vertical isolation type breaker as per IS 131148, as amended up to date and addition specification, having capacities mentioned below, single break, trip free mechanism, manually charged and auto, manually closing breakers suitable for use on 11 KV 3 Phase, 50Hz, AC Supply with short circuit fault level of 350 MVA complete with self-contained fully interlocked, rack in and rack out mechanism, Air insulated but in capsulated copper bus bar of 630AMP capacity, breaker featured with mechanical on /off indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 Nos + 4 NC and equipped with following switch gears and accessories including connections suitable for 3 x 95/12/150Sqmm XLPE 11 KV Cable (Cable entry from bottom), end terminal head shrinkable jointing material etc as required. (Cost of end termination is not included in this items).
(a) Incoming: 2 Nos 630 AMP VCB.
(i) 2 Nos: 11 KV/110 Volt PT Class 0.5 accuracy and 100 VA burden and protection and fuses/MCB for HT metring up to 12KV on incomer.
(ii) 2 Nos: Digital load manage with built in selector switch.
(iii) 2 Nos : Microprocessor based numerical relay with O/L,E/F and S/C Protection.
(iv) 2 Nos: Set of Dual core Dual ratio 3CT’s 100/50/1+1A Class 1 of 2.5 VA Burden and accuracy class -0.5 for metering and class 5P10 for protection.
(b) Out going- 3 Nos 630 AMP VCB.
(i) 3 Nos : Digital multifunction meter for measuring HT Voltage up to 12 KV, current, power factor KVA, KVAh, KW, Energy with suitable CT’s & MCB,s for protection.
(ii) 3 Seal of duel core dual ratio 3 nos CTs 150/50/5/5A of 15 VA burden and accuracy class 1.0 for metering and class 5P10 for protection. | 1 | Each | 17,50,000 ₹17.5 L | 23,84,000 ₹23.8 L | 20,95,000 ₹20.9 L | 23,20,000 ₹23.2 L | 21,08,000 ₹21.1 L | 19,90,000 ₹19.9 L | 23,10,000 ₹23.1 L | 22,00,000 ₹22 L |
| 2.01(c) Power Pack. Power pack with 220 VAC Input and 24 V DC continues out put suitable for closing / tripping / indication of 4 Nos HT Panel board with 2 Nos 12 V Each AMF Batteries of 100 AH Capacity, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of ammeter and voltmeter including connection with 2.5 Sqmm FRLS insulated copper conductor cable etc as required. (d) CFL Illumination in each compartment. (e) Space heater for each compartment. (f) 3 Phase indictor for each compartment. (g) Suitable connection for measuring and protection device with indication. (h) Necessary interlocking arrangement for safety and operation. (j) Operation remote handle for switches are charging spring and test arrangement. (k) Suitable protection as per manufacturing recommendation with PCC 1:4:8 B1 using 20mm aggregate for foundation. (l) Thickness 3mm internal Arc 21KV for 1 Sec. (m) Short circuit with stand current – 26.3KV for 3 Sec. | |||||||||||
| 2.02(n) Bus Connected PT Unit-01 No for metering consisting of following :- (i) Type M : Air insulated metering module 12 KV, 630A 20 KA for 3 sec. (ii) Three phase transformers of the ratio 11 KV/1.732/110 V/1.732.25 VA Class 1.0 with HT fuses on primary side and MCB on secondary side. (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVRA (iv) 1 CFL illumination. (v) 1 Space heater with thermostate. (vi) 1 RYB phase indicator (vii) 1 Cable support busbar, stand for 3 way unit, 1 manometer & 1 perating handle. (viii) 1 Set bushing for external bushbar connection along with bushbar cover & sleeved bushbars for coupling. (ix) 2x12 V Battery with battery charger of suitable burden for motor operation. Input 230 V AC & output 24 V DC. (o) Capacitive voltage indicator fixed type VPIS 9-15KV. (p) necessary interlocking arrangement for sefty and operation. (q) One No operating handle for manual operation. (r) One No Mono meter. (s) Safety interlock shall be provided as per relevant IEC/IS standard and manufactures directions. (t) Safety interlocks shall be provided as relevand IEC/IS standard and manufactures directions. (u) Above switchgear shall confirm to all relevant IEC/IS standard. (v) Manual operation of vaccum circuit breaker should be possible without dismantling the motor from RMU. the motor should be fitted in such a way that it should not be outside from covers of RMU. Make:- Schneider/ABB/Siemens | |||||||||||
| 3.00 | Supply, laying & testing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed . | 12 | Each | 3,800 ₹45,600 | 6,000 ₹72,000 | 2,950 ₹35,400 | 9,500 ₹1.1 L | 9,000 ₹1.1 L | 7,000 ₹84,000 | 5,000 ₹60,000 | 6,500 ₹78,000 |
| 4.00 | Supply, laying & testing cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed . | 18 | Each | 3,800 ₹68,400 | 5,000 ₹90,000 | 2,600 ₹46,800 | 9,000 ₹1.6 L | 8,400 ₹1.5 L | 7,000 ₹1.3 L | 5,000 ₹90,000 | 7,500 ₹1.4 L |
| 5.00M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable including necessary excavation and retuening filling work complete all as specified & directed of following size :- | |||||||||||
| 5.01 | Size 50 sqmm to 95 sqmm | 5 | Each | 10,800 ₹54,000 | 10,000 ₹50,000 | 5,000 ₹25,000 | 14,500 ₹72,500 | 18,000 ₹90,000 | 9,500 ₹47,500 | 7,000 ₹35,000 | 12,000 ₹60,000 |
Updated dates
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
13 Nov 2025, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
SPECIAL REPAIR FOR REPLACEMENT OF HT DISTRIBUTION NETWORK AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2025_MES_727658_2
82012/W/E8
Open Tender
Civil Works
180 days
Prayagraj
Class B and Category b(ii)
6 documents required · 6 mandatory
₹1,000
GE (West) Prayagraj
₹2.1 L
Yes
11 Feb 2026
23 Oct 2025
20 Nov 2025
23 Oct 2025
13 Nov 2025
30 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tenderdocument.pdf
Tender Documents • 0.72 MB
Makes.pdf
Additional Documents • 0.56 MB
Particularspecifications.pdf
Additional Documents • 0.58 MB
Specialcondition.pdf
Additional Documents • 0.49 MB
Errata2.pdf
Additional Documents • 0.18 MB
BOQ_824684.xls
BOQ • 0.83 MB
Download all tender documents and submit your bid