Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹4.9 L
Closing Date
30 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Outsourcing of PSI maintenance activity of 25 KV AC Traction System over DLI-UMB area (PSI/NUR, PSI/PNP, PSI/KKDE) for a period of Two years.
02-TRD-NDLS-2026-27
02-TRD-NDLS-2026-27
Open
Works - General
24 Months
Delhi, Delhi
₹0
₹4.9 L
30 Apr 2026
9 Apr 2026
16 Apr 2026
103 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,64,79,502.74 | ||
| — | 200.00 | — | — | ||
| 1(a). Maintenance of Traction Power Transformer bay of 25kV AC Railway Traction Sub Stations. Monthly Maintenance of Traction Power Transformer bay at TSS. | — | — | — | 12,66,834 | |
| — | 20.00 | — | — | ||
| 1(b). Maintenance of Traction Power Transformer bay of 25kV AC Railway Traction Sub Stations. Half Yearly Maintenance of Traction Power Transformer bay at TSS. | — | — | — | 1,87,250 | |
| — | 20.00 | — | — | ||
| 1(c). Maintenance of Traction Power Transformer bay of 25kV AC Railway Traction Sub Stations. Yearly Maintenance of Traction Power Transformer bay at TSS. | — | — | — | 2,50,604.6 | |
| — | 330.00 | — | — | ||
| 2(a). Maintenance of 25kV Feeder Circuit Breaker bay of 25kV AC Railway TSS/SP/SSP. Monthly Maintenance of 25kV Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY) | — | — | — | 15,36,717.6 | |
| — | 30.00 | — | — | ||
| 2(b). Maintenance of 25kV Feeder Circuit Breaker bay of 25kV AC Railway TSS/SP/SSP. Yearly Maintenance of 25kV Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY) | — | — | — | 2,44,478.4 | |
| — | 82.00 | — | — | ||
| 3(a). Maintenance of Isolators of 25kV AC Railway Traction Sub Stations. Half Yearly Maintenance of 25kV Single Pole Isolator at TSS. | — | — | — | 1,79,671.84 | |
| — | 82.00 | — | — | ||
| 3(b). Maintenance of Isolators of 25kV AC Railway Traction Sub Stations. Yearly Maintenance of 25kV Single Pole Isolator at TSS. | — | — | — | 2,15,605.06 | |
| — | 64.00 | — | — | ||
| 3(c). Maintenance of Isolators of 25kV AC Railway Traction Sub Stations. Half Yearly Maintenance of 220kV or 132kV or 66kV Double Pole/Triple Pole Isolator at TSS. | — | — | — | 1,96,323.2 | |
| — | 64.00 | — | — | ||
| 3(d). Maintenance of Isolators of 25kV AC Railway Traction Sub Stations. Yearly Maintenance of 220kV or 132kV or 66kV Double Pole/Triple Pole Isolator at TSS. | — | — | — | 2,52,416 | |
| — | 120.00 | — | — | ||
| 4(a). Maintenance of Battery & Battery chargers of 25kV AC Railway Traction Sub Stations. Fortnightly Maintenance of Battery & Battery chargers at TSS. | — | — | — | 2,32,483.2 | |
| — | 80.00 | — | — | ||
| 4(b). Maintenance of Battery & Battery chargers of 25kV AC Railway Traction Sub Stations. Monthly Maintenance of Battery & Battery chargers at TSS. | — | — | — | 1,54,988.8 | |
| — | 30.00 | — | — | ||
| 4(c). Maintenance of Battery & Battery chargers of 25kV AC Railway Traction Sub Stations. Quarterly Maintenance of Battery & Battery chargers at TSS. | — | — | — | 81,369 | |
| — | 10.00 | — | — | ||
| 4(d). Maintenance of Battery & Battery chargers of 25kV AC Railway Traction Sub Stations. Yearly Maintenance of Battery & Battery chargers at TSS. | — | — | — | 31,317.1 | |
| — | 20.00 | — | — | ||
| 5. Half yearly Maintenance of AC & DC Distribution panel and Control & Relay panel at TSS. (EACH TSS) | — | — | — | 78,971.2 | |
| — | 20.00 | — | — | ||
| 6(a). Maintenance of Capacitor bank bay of 25kV AC Railway Traction Sub Stations. Quarterly Maintenance of Capacitor bank bay at TSS. | — | — | — | 1,32,211 | |
| — | 10.00 | — | — | ||
| 6(b). Maintenance of Capacitor bank bay of 25kV AC Railway Traction Sub Stations. Half Yearly Maintenance of Capacitor bank bay at TSS. | — | — | — | 79,326.5 | |
| — | 10.00 | — | — | ||
| 6(c). Maintenance of Capacitor bank bay of 25kV AC Railway Traction Sub Stations. Yearly Maintenance of Capacitor bank bay at TSS. | — | — | — | 93,942.5 | |
| — | 1700.00 | — | — | ||
| 7(a). Maintenance of 25kV Interrupters at TSS/SP/SSP. Monthly Maintenance of 25kV Interrupters at TSS/SP/SSP. | — | — | — | 39,58,212 | |
| — | 170.00 | — | — | ||
| 7(b). Maintenance of 25kV Interrupters at TSS/SP/SSP. Half Yearly Maintenance of 25kV Interrupters at TSS/SP/SSP. | — | — | — | 4,74,985.1 | |
| — | 170.00 | — | — | ||
| 7(c). Maintenance of 25kV Interrupters at TSS/SP/SSP. Yearly Maintenance of 25kV Interrupters at TSS/SP/SSP. | — | — | — | 5,54,149 | |
| — | 62.00 | — | — | ||
| 8(a)Yearly Maintenance of gantry at TSS/SP/SSP. Yearly maintenance of Category-A gantry. (EACH POST). | — | — | — | 9,79,245.36 | |
| — | 4.00 | — | — | ||
| 8(b). Yearly Maintenance of gantry at TSS/SP/SSP. Yearly maintenance of Category-B gantry. (EACH POST). | — | — | — | 91,650.08 | |
| — | 1430.00 | — | — | ||
| 9. Yearly Maintenance of Earthing station at TSS/SP/SSP. | — | — | — | 2,51,851.6 | |
| — | 672.00 | — | — | ||
| 10(a). Maintenance of Battery & Battery chargers at SP/SSP. Fortnightly Maintenance of Battery & Battery chargers at SP/SSP. | — | — | — | 5,99,444.16 | |
| — | 448.00 | — | — | ||
| 10(b). Maintenance of Battery & Battery chargers at SP/SSP. Monthly Maintenance of Battery & Battery chargers at SP/SSP. | — | — | — | 6,74,934.4 | |
| — | 168.00 | — | — | ||
| 10(c). Maintenance of Battery & Battery chargers at SP/SSP. Quarterly Maintenance of Battery & Battery chargers at SP/SSP. | — | — | — | 3,54,340.56 | |
| — | 56.00 | — | — | ||
| 10(d). Maintenance of Battery & Battery chargers at SP/SSP. Yearly Maintenance of Battery & Battery chargers at SP/SSP. | — | — | — | 1,31,531.68 | |
| — | 668.00 | — | — | ||
| 11(a). Maintenance of Auxiliary Transformer. Quarterly Maintenance of Auxiliary Transformer. | — | — | — | 14,92,245.2 | |
| — | 334.00 | — | — | ||
| 11(b). Maintenance of Auxiliary Transformer. Half Yearly Maintenance of Auxiliary Transformer. | — | — | — | 6,75,535.04 | |
| — | 334.00 | — | — | ||
| 11(c). Maintenance of Auxiliary Transformer. Yearly Maintenance of Auxiliary Transformer. | — | — | — | 6,97,325.2 | |
| — | 24.00 | — | — | ||
| 12(a). Maintenance of Transmission line bay of Railway Traction Sub stations. Quarterly Maintenance of Transmission line bay at TSS. (EACH BAY) | — | — | — | 2,24,688.72 | |
| 12(b). Maintenance of Transmission line bay of Railway Traction Sub stations. Yearly Maintenance of Transmission line bay at TSS. (EACH BAY) | — | 8.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022AC9.pdf
ATTACHMENT
GCCApril-2022AC10.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly.pdf
ATTACHMENT
GCCApril-2022AC11.pdf
ATTACHMENT
Tender022026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .