Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | l2₹22.8 L+₹1.7 L (8.25%)Rejected-Finance | l2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹23.8 L+₹2.8 L (13.1%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹25.8 L+₹4.7 L (22.3%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
21 Dec 2022, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND ALLIED ITEM(S) AT MH, JCOs/ORs MD ACCN AND ZONE D AREA UNDER GE (E) MATHURA
2022_MES_564934_1
8200-1308/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUEMTNS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
16 Jan 2023
24 Nov 2022
23 Dec 2022
24 Nov 2022
21 Dec 2022
9 Dec 2022
24 Nov 2022 - 14 Dec 2022
Amount
Taking down carefully copper/aluminum copper point wiring (light, fan, socket or power, bell etc.) complete including fixtures & fittings such as ceiling rose, socket, Pendant, regulator, sockets, light fitting etc and removing the material from site and making good the disturbed surfaces of walls, ceiling etc complete all as directed.
Taking down carefully old unserviceable submain wiring of any type complete all as specified and as directed.
Taking down old unserviceable existing SP/SPN/TPN DB/ enclousers any size and type/any descriptions MCB and making good disturbed surface of walls to match the surrounding surface complete all as specified and as directed.
Taking down existing unserviceable tube light fittings/ bulkhead fitting/ building street light fitting/ ceiling fittings of any type/make from wall/ ceiling etc complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC single core PVC unsheathed (FRLS) copper conductor cable, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less than 20mm dia) and its all accessories complete concealed in wall including cutting & chases and making good all to the disturbed surfaces to match the existing surface, land providing modular flush metal boxes including base plate and cover plate for mounting modular switches, sockets, regulators etc including earth wire of PVC single core sheathed (FRLS) copper conductor cable of 1.5 Sqmm size in green colour complete all as specified in SSR Part-I & II & directed by the Engineer-in-Charge for the followings:-
One light/fan point controlled by one way modular switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way modular switch 5 amp on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way modular switch on independent board complete all as specified and as directed.
One bell point controlled by one push button on independent board complete all as specified and as directed.
One light point controlled by 2 way modular switch complete all as specified and as directed.
All as per item No. 5 here-in-above but surface conduit wiring complete all as specified and as directed .
All as per item No. 5 here-in-above but for 3/5 pin 16 Amps socket outlet independent with 4 Sqmm PVC unsheathed (FRLS) copper conductor cable complete all as specified and as directed .
All as per item No. 5 here-in-above but for 25 Amps AC enclosure independent with 4 Sqmm PVC sheathed (FRLS) copper conductor cable complete all as specified and as directed .
S&F Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F bell push single pole one-way, 6 Amps 1 Module with indicator complete all as specified and as directed.
S&F Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F Modular fan Regulator electronic step type 1 Module complete all as specified and as directed.
S&F modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
S&F Modular switch single pole two-way, 6 Amps 1 Module complete all as specified and as directed.
S&F modular type box with socket plug top and MCB with two pin and one pin for earth plug and socket complete with one single pole MCB 16 Amps complete all as specified and as directed.
S&F in repair switch piano type, SP, one way, flush type 5 Amps complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 5 pin 5 Amp complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 3 pin 5 & 15 Amp complete all as specified and as directed.
S&F in repair switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair bell push siwtch piano flush type, SP, one way, 5 Amps complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair Bell Multi Music type, 230 Volts including connection complete all as specified and as directed
S&F in repair Bell Ding dong type, 230 Volts including connections complete all as specified and as directed.
S&F in repair step type electronic fan Regulator piano flush type, on existing phenolic laminated sheet etc complete all as specified and as directed.
S&F Sub main wiring with two single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranderd copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 20 mm dia and all its accesories concealed in wall/roof including cutting & chases and making good the disturbed surface, including PVC insulated 4 sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one RM.
S&F of Sub main wiring with two run of single core 6 Sqmm cable PVC insulated unsheathed (FRLS) cable with stranderd coper conductor, 1100 votls grade drawn through and including PVC conduit 25 mm dia and its all accessories concealed in wall/roof including cutting & chases and making good the disturbed surface including PVC insulated 6sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire & 25mm PVC Conduit shall be measured as one RM.
S&F Sub main wiring with two run of single core 10 Sqmm cable PVC insulated unsheathed (FRLS) cable with strandard copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 25 mm dia including all its acessories concealed in wall/roof including necessary cutting/chase and making good distured surface including 10 Sqmm PVC insulated unsheathed stranded (FRLS) cable for earth wire complete all as specified and as directed. Note : Two runs of 10 Sqmm cable, one run of 10 Sqmm earth wire & 25mm PVC Conduit shall be measured as one unit length.
S&F submain wiring with two runs of single core 6 sqmm PVC insulated unsheathed (FRLS) cable with standard copper conductor 1100 volt grade drawn through existing PVC conduit including 6 Sqmm PVC insulated unsheated strandard (FRLS) copper conductor cable as earth complete all as specified and as directed. Note : Two runs of 6 Sqmm single core cabe, one run of 6 Sqmm earth wire shall be measured as one RM.
S&F indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with 1x 20 watt LED Tube including polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified and as directed.
S&F of indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete all as specified and as directed.
S&F building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
S&F MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F MCB SPN 63 Amps, 'C' series , breaking capacity10KA, 240V complete all as specified and as directed.
S&F of MCB SPN 40 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F of MCB SPN 6-32 Amps, 'C' series , breaking capacity 10KA, 240V complete all as specified and as directed.
S&F of MCB SP 6 - 32 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F SP enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 1/2 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 3/4 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 6/8 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and directed.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc required to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch / socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc reqiored to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F PVC insulated FRLS, unsheathed cable multi stranded copper conductor of size 4.0 Sqmm with and including PVC pipe/Casing -Caping as per site requirement during wiring complete all as specified and as directed.
S&F in repair Modular metal flush box 1/2 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 3 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 4 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 6 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 8 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 12 Module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 1/2 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 8 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 12 module complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, unsheathed, (FRLS) 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing having provision for gang box for fixing switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light point/fan point/bell point controlled by one switch.
One 3 pin 5 Amps socket point controlled by one way switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board.
All as per item No. 60 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S&F switch piano flush type 5 Amps, SP, one way complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 5 pin 5 Amp complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 3 pin 5/15 Amp complete all as specified and as directed
S&F in repair ceiling fan 1200 mm sweep AC 230 Volt single phase five star rating including all fixing accessories complete and depositing the old one in MES store yard complete all as and as directed.
S&F in repair exhaust fan 300 mm heavy duty metallic body AC 230Volt single phase including louvers and fixing accessories including depositing the old one in MES store yard complete all as directed.
S&F switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair bell push single pole one-way, 6 Amps 1 Module with indicator complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
Taking down carefully service connection of any type complete all as and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables etc and getting out complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each after cables have been laid and tested complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/duct/fixing on walls/poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box and testing complete all as specified and as directed of following sizes :- Note:- HDPE pipe rate shall be deemed to be included in quoted rate above.
10 sqmm 2 core.
16 sqmm 2 core.
16 sqmm 4 core.
25 sqmm 4 core.
S&F MCB TPN 40 to 100 Amps, 'C' series , breaking capacity 10KA, 415V complete all as specified and as directed.
S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder coated with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable MCBs with connections complete all as specified and as directed. Note : MCB /MCCB, DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
S&F MCCB 4 pole 415 Volts thermal magnetic based adjustable type 125 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
S&F MCCB 4 pole 415 Volts thermal magnetic based adjustable type 160 Amp, with breaking capacity 25kA Complete all as spccified and as directed.
S&F MCCB 4 pole 415 Volts thermal magnetic based adjustable type 250 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
S&F ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Taking down old unserviceable existing MCB any type/size and making good disturbed surface/wall as per existing complete all as specified and as directed.
S&F switch piano flush type single pole one-way, 15 Amps 240 Volt complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 15 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete all as specified and as directed.
S&F in repairs Sub main wiring with two single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranderd copper conductor, 1100 votls grade drawn through existing PVC conduit, including PVC insulated 4 sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one RM.
S&F in repair fresh air/ventilator fan made of sturdy engineering plastic with built in louvers, AC, 230Volt single phase, 50 Hz, including depositing the old one in MES store yard complete of following sizes :-
150 mm Sweep
200 mm Sweep
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified and as directed.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC single core PVC unsheathed (FRLS) copper conductor cable, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less than 20mm dia) and its all accessories complete concealed in wall including cutting & chases and making good all to the disturbed surfaces to match the existing surface and modular flush metal boxes including base plate and cover plate for mounting modular switches, sockets, regulators etc including earth wire of PVC single core sheathed (FRLS) copper conductor cable of 2.5 Sqmm size in green colour complete all as specified in SSR Part-I & II & as directed.
S&F in repair siwtch piano flush type, SP, two way, 5 Amps complete all as specified and as directed.
S&F in repair Modular switch single pole two-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair PVC insulated sheathed 1.5 sqmm 3 core cable 1100 volts grade ISI marked copper conductor complete all as specified and as directed.
S&F in repair SPN/2P RCBOs 32 Amp, 100 Ams, 230volt 10kA complete all as specified and as directed.
S&F in repair LED Round recess mounted downlighter with die cast aluminium housing 24w complete all as specified and as directed.
S&F in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light fitting 1X18 watt 4' LED Tube fitting complete all as specified and as directed.
S&F in repair of LED T-5 intergrated Batten PC housing extruded 2' light fittings 9W complete all as specified an as directed.
S&F in repair of Recess Type LED light fitting 2X2, Square shape 36W, 230V, complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed.
S&F in repair LED T8 Tube 20w with aluminium extrusion heat sink for optimum performance complete all as specified and as directed.
S&F in repair LED retrofit lamp 9 Watt complete all as specified and as directed.
S&F in repair of LED PLL Lamp 18w complete all as specified and as directed.
S&F in repair Decorative wall light fitting incl 9w LED lamp complete all as specified and as directed.
S&F in repair Decorative wall light fitting stainless steel rust free fixture with white glass diffuser with 7.5/9w LED lamp complete all as specified and as directed.
S&F in repair environmental friendly, ultra modern, energy saving, surface mounted, LED Bulk Head fitting of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed.
S&F in repair building street light fitting, IP66 powder coated pressure die cast aluminium with heat resistant toughened glass complete of 40 Watt capacity including fixing arrangement complete with all accessories including connecting up with twin core copper conductor cable with suitable size all as directed.
S&F LED Bollard flare fitted with low glare diffuser 12 watt with integrated driver with uniform light distribution complete all as specified and directed.
S&F in replacement Post top lantern LED type 20 Watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F factory made epoxy powder coated Distribution Board TP & N 4 ways (TPN MCB DB ) with metal door ( IP-43 protection ) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts complete all as specified and as directed.
S&F in repair 4 Pole TPN MCB 63 Amps ,415 V, 50Hz, with repturing capacity 16 KA complete all as specified and as directed.
M&L for Sand filling in trenches with clean dry fine sand including gently punning around cables complete all as specified and as directed. Note : Punned depth shall only be measured for payment as specified.
Supply and Laying Unreinforced precast concrete cable cover class LV type 1, size 250mmx150mmx40mm complete all as specified and as directed.
Taking down existing energy meter with box from panel/wall and refixing the same with all connection both input and output supply from DB complete all as specified and as directed. Note : Required copper conductor (FRLS) of suitable size for connection shall be included in quoted rate.
M/s RCC
Ms Kamal Kant Agarwal
B S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .