Ex.Engineer Electrical SKIMS
Ex.Engineer Electrical SKIMS Soura
Fresh Electrification which includes providing and fixing of LED Luminaries Fans and safety Devices etc in Newly Proposed first floor of Attendants Shelter Shed near Central Lab IPD Block at SKIMS MCH Bemina
2020_SKIMS_96066_1
eNIT SIMS HEE EET 09 of 2020-21 Dt.23.04.2020
Open Tender
Electrical Works
Item Rate
30 days
SKIMS MCH Bemina
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
CAO SKIMS MCH Bemina
₹4,800
Yes
17 Sept 2020
24 Apr 2020
20 May 2020
25 Apr 2020
15 May 2020
26 Apr 2020
Amount
Wiring to be carried out for fixing of fresh lighting point using 3x1.5 mm2 (P+N+E)pvc insulated multi-strand FR copper wire (Havells /Polycab/Paramount/Finolex make) in pvc Conduit. Conducting system including cost of cutting/making good chases in brick work,rough plastering and including the cost of supplying &fixing G.I box mounted by 6 Amp switch.
Wiring to be carried out for fresh heating point in concealed manner through PVC conduit of 25 mm dia 2 mm thick. using multi strand 3 x 2.5 mm.sq pvc insulated copper wire (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch socket combine 15/16 amps 5 pin F/T SSK/Havell's make to be fitted on Bakelite sheet suitable size, M.S/Wooden box, rowel plugs & screws etc. complete Point with civil work .
Circuit wire to be laid / Replacement of damaged wire as per site requirements using multi strand pvc insulated copper wire (Havells /Finolex/ Polycab/Paramount make FR) (excluding the cost of conduit)
a) 1 x 4 sq.mm copper wire for heating points (P+N+E) for secondry point. ( for circuit wires.( 5 ckt))
b) 1 x2.5 sq.mm copper wire for light points ( 11 ckts )
P/laying of 25mm medium class PVC conduit 2mm thick along with all accessories including cutting the wall and making good the same plastering complete as required at site.(in recessed manner) (Ravindra /Polycab Atul make)
P/fixing of Double locked medium duty pvc channel 25x 2mm. (Flair/polycab/Ravindra make)
Providing and fixing of Switch socket combine 15 amps 5 pin( SSK/ Havell,s make) for secondry heating point.
P/F of 3 pin socket 5/6 amps 5 pin (SSK/ Havells make )
P/f of bakelite /Phenolic Laminated Sheet 3 mm thick for fixing of S.S comb. 16 amps and inspection holes etc.
P/fixing of Led 1200 mm long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 85 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable etc as required at site.( Philip's/ Havel's/Wipro/ Trilux make )
P/fixing of Led 2feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 85 with minimum sytem lumens 1300 and maximum wattage 12 including connection with multistrand copper conductor 3 core cable etc as required at site.( Philip's/ Havel's/Wipro/ Trilux make )
P/installation of Ceiling fans copper wound 1200 mm heavduty.(Havells/crompton/Bajaj )
P/installation of Exhaust fans 12" copper wound heavduty.(Havells/crompton/Bajaj )
providing and fixing of Fan regulater stepped type one way complete as required.(Havells Reo/ SSK/Anchor penta pc make)
Providing fixing of ply board 12 mm thick suitable size for above mentioned exhaust fans ( 12"x 12") with central hole and screws etc. complte with civil work.
Supplying and fixing 10 way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts TPN, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (SSK/Havells/Indo Asian /Schneider make)
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker TPN 63 amps suitable for inductive load the MCB DB should be complete with connections, testing and commissioning etc. as required. (Legrand/Schneider acti -9/Siemens make)
P/F of MCB SP 10A to 16A for lighting and heating points in above D.B
Supply & Laying,Testing, connecting and commissioning of one number PVC insulated and PVC sheathed/ XLPE power cableof 1.1 KV grade of 35 sq mm 3.5 core cable( Havell's / Polycab/Glioster make) from main substation to Sub above D.B The job including cost of thimbling and crimping etc. complete as required at site.
Providing and fixing G.I round bear wire 8 SWG for earthing from Main substation up to Sub D.B Attendent Shelter Shed
M/S BHAT SYNDICATE
M/s BILAL ELECTRIC GOODS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .