Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
12 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
CWE NW MUMBAI
CWE NW MUMBAI
SR REPLACEMENT OF 11 KV TRANSFORMERS AND HT OCBs AGAINST BER AT INS ANGRE AND INS TRATA UNDER HQ MNA AND SR UPGRADATION OF 750 KVA TRANSFORMER TO 1000 KVA CAPACITY AGAINST BER AT INS VAJRABAHU, NAVAL DOCKYARD, MUMBAI
2026_MES_798854_1
8571/CWE(NW)MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE NW KUNJALI
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE NW KUNJALI
₹1.8 L
Yes
16 Nov 2026
16 Nov 2026
14 Dec 2026
16 Nov 2026
12 Dec 2026
7 Dec 2026
16 Nov 2026 - 4 Dec 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: COMMANDER WORKS ENGINEER (NAVAL WORKS) MUMBAI
Name of Work : SPECIAL REPAIR/REPLACEMENT OF 11 KV TRANSFORMERS AND HT OCBs AGAINST BER AT INS ANGRE AND INS TRATA UNDER HQ MNA AND SPECIAL REPAIR/UPGRADATION OF 750 KVA TRANSFORMER TO 1000 KVA CAPACITY AGAINST BER AT INS VAJRABAHU (A-14 BUILDING), NAVAL DOCKYARD, MUMBAI.
Contract No: 8571/CWE (NW) MUMBAI/E8
Sl. No. Item Code / Make Quantity Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1.02 (d) Dehydrating breather with initial filling of silica gel. (e) Explosion vent/pressure relief device, thermometer pocket, oil drain valve, lifting lugs, oil filling arrangement, air release valve and four numbers detachable solid cast-steel rollers. (f) One number 100 mm diameter dial-type thermometer with 0–120°C range, maximum temperature indicator and resetting arrangement. (g) Two numbers earthing terminals on transformer tank suitable for connecting 50 mm × 6 mm GI earth strips. (h) Rating plate and terminal marking plate. (j) Additional neutral bushing in LV cable box for independent neutral earthing. The transformer shall be supplied complete with insulating oil, all necessary fittings, accessories and hardware, installed, tested and commissioned at site, complete in all respects, as specified and directed by the Engineer-in-Charge. 0 Excess(+) Full Conversion INR
1.03 Notes for Item No. 1.01: (i) A suitable platform for mounting the transformer shall be provided as per the OEM's recommendations, and the cost thereof shall be deemed to be included in the quoted rates. (ii) The General Arrangement (GA) drawing of the transformer shall be submitted by the contractor and got approved from GE before commencement of manufacturing. (iii) Pre-dispatch factory inspection of the transformer shall be carried out by the representative of Accepting officer at the OEM's premises before dispatch. (iv)The cost of providing trained manpower, materials, testing equipment, relay setting arrangements and all other necessary resources required for the inspection and testing shall be deemed to be included in the quoted rates. 0 Excess(+) Full Conversion INR
1.06 Notes: (i) The General Arrangement (GA) drawing of the HT panel shall be submitted by the contractor and got approved from GE before commencement of manufacturing. (ii) Factory inspection of VCB panels shall be carried out by the representative of Accepting Officer at the OEM's premises before dispatch. (iii)The cost of providing trained manpower, materials, testing equipment, relay setting, calibration and all other necessary arrangements required for inspection and testing shall be deemed to be included in the quoted rates. 0 Excess(+) Full Conversion INR
5 (c) Oil conservator with oil level gauge and filter-type drain valve. (d) Dehydrating breather with initial filling of silica gel. (e) Explosion vent/pressure relief device, thermometer pocket, oil drain-cum-filter valve, lifting lugs, oil filling arrangement with cap/plug, connection plate, air release valve and four numbers of detachable solid cast-steel rollers. (f) One number 100 mm diameter, dial-type, vapour-pressure thermometer having a range of 0–120°C, with metal protective guard, maximum temperature indicator and resetting arrangement. (g) Two numbers of earthing terminals on transformer tank suitable for connecting 50 mm × 6 mm GI earth strips for body earthing. (h) Rating plate and terminal marking plate. (i) One additional neutral bushing in the LV cable box for independent neutral earthing. The transformer shall be supplied complete with insulating oil, all necessary fittings, accessories and hardware, installed, tested and commissioned at site, complete in all respects, as specified and directed by the Engineer-in-Charge. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole. 0 Excess(+) Full Conversion INR
6 Notes: (i) A suitable platform for mounting the transformer shall be provided as per OEM recommendations, and the cost thereof shall be deemed to be included in the quoted rates. (ii) The cost of disconnecting and dismantling the existing transformer from the powerhouse, including necessary arrangements such as cutting/alteration of the shutter door and wall for removal, shifting and depositing the dismantled transformer at MES store yard, and making good the disturbed portions to match the existing condition, shall be deemed to be included in the quoted rates. (iii) The General Arrangement (GA) drawing of the transformer shall be submitted by the contractor and got approved from GE before commencement of manufacturing. (iv) Pre-dispatch factory inspection of the transformer shall be carried out by the representative of Accepting officer at the OEM's premises before dispatch. (v) The cost of providing trained manpower, materials, testing equipment, relay setting arrangements and all other necessary resources required for inspection and testing shall be deemed to be included in the quoted rates. 0 Excess(+) Full Conversion INR
8 A. Incoming: (a) 1600 A, 4-pole, 415 V, 50 kA, manually operated draw-out type ACB with thermal-magnetic release – 01 No. B. Outgoing: (a) 630 A, 4-pole, 25 kA, thermal-magnetic MCCB – 01 No. (b) 400 A, 4-pole, 16 kA, thermal-magnetic MCCB – 02 Nos. (c) 320 A, 4-pole, 16 kA, thermal-magnetic MCCB – 06 Nos. (d) 250 A, 4-pole, 16 kA, thermal-magnetic MCCB – 09 Nos. (e) 125 A, 4-pole, 16 kA, thermal-magnetic MCCB – 03 Nos. (f) 350 A, 440 V, manually operated off-load changeover switch – 01 No. C. Metering and Indication: (a) Digital voltmeter – 01 No., (b) Digital ammeter with suitable CTs – 01 No., (c) LED-type phase indication lamps (R, Y & B) – 01 Set. The complete LT panel shall be supplied with all necessary internal connections, busbar supports, insulators, control wiring, terminals, protective devices, interconnections and hardware required for satisfactory operation, complete in all respects, as specified and directed by the Engineer-in-Charge. 0 Excess(+) Full Conversion INR end
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8571_8571generaltender.pdf
Tender Documents • 0.93 MB
8571_8571nit.pdf
Tender Documents • 0.39 MB
8571_APPx B to PS.pdf
Tender Documents • 0.52 MB
8571_appxA.pdf
Tender Documents • 0.39 MB
8571_AppxCto PS.pdf
Tender Documents • 0.80 MB
8571_PS.pdf
Tender Documents • 0.49 MB
BOQ_896196.xls
BOQ • 13.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .