| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | L1 | Accepted-AOC Due to being L1 | |
| 2 | L2₹27.1 L+₹1.7 L (6.57%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.4 L+₹2.0 L (7.88%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹28.8 L+₹3.4 L (13.4%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹33.4 L+₹8.0 L (31.3%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Maint of LT infrastructure and connected accessories in AOR of AGE (E/M) under GE (Utilities) Udhampur
2022_MES_507573_1
GE/U-64/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹60,000
Yes
29 Mar 2022
12 Feb 2022
14 Mar 2022
12 Feb 2022
12 Mar 2022
26 Feb 2022
90 days
Amount
Supply, installation, testing and commissioning (testing factory made and tested CPRI type test certified) of LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made out of 3.15mm thick CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings, base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming (a) ACB 800 amps, fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 50 KA-01 No. Make :- L&T, Legrand, Scheineiders, Havells, ABB,C&S (b) Bus bar electrolytic grade copper 1000Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing (a) MCCB 315/320 amps, 4 pole, 35/36 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- &T, Legrand, Scheineiders, Havells, ABB,C&S (b) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade - 2 Nos. Make :- &T, Legrand, Scheineiders, Havells, ABB,C&S Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suitable gun metal /SS glands.
All as per serial item No.1 here-in-before but with following accessries complete for Sub Panel :- Incoming (a) MCCB FP, 400 Amp, 50 KA -01 Nos Make: H&T, Legrand, Scheineiders, Havells, ABB,C&S (b) Bus bar electrolytic grade copper 600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set. Outgoing (a) MCCB TPN, 315 Amp , 36 KA Make: H&T, Legrand, Scheineiders, Havells, ABB,C&S- 01Nos. (b) MCCB TPN, 250 Amp , 36 KA Make: H&T, Legrand, Scheineiders, Havells, ABB,C&S- 01Nos. (c) MCCB TPN, 200 Amp , 36 KA Make: H&T, Legrand, Scheineiders, Havells, ABB,C&S- 01 Nos (d) MCCB TPN, 160 Amp, 25 KA, Make : H&T, Legrand, Scheineiders, Havells, ABB,C&S- 01 Nos Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing Cables shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed by Engr-in-Charge. Note: - (a) The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b) Prooning of all tree branches in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the job with in time as directed. (d) Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply. However full assistance will be provided by MES staff. (f) The contractor will provide proper tools and safety devices to his staff for prooning of trees.
LT panel, out door (Kiosk type), weather & vermin proof MS sheet housing 3.15mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 100 Amp, 25 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size,Including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing LT underground cable of following sizes, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts Including taking out existing unserviceable cable complete all as specified and directed by Engr-in-Charge. Note: - GI Tubing and earth work shall be measured and paid seperately under respective item of BOQ.
300 Sqmm 3.5 Core.
240 Sqmm 3.5 Core.
185 Sqmm 3.5 Core.
120 Sqmm 3.5 Core.
Straight through joint kit, heat shrinkable type, suitable for 50 to 95 Sqmm LT underground cables complete all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type, suitable for 120 to 185 Sqmm LT underground cables complete all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type, suitable for 240 Sqmm to 300 sqmm LT underground cables complete all as specified and directed by Engr-in-Charge.
ACB 4 pole, Ics=100%Icu- 50 KA, 415 Volts, 630 Amps (in replacement) with adjustable thermal and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make :- L&T, Legrand, Scheineiders, Havells, ABB,C&S
ACB 4 pole, Ics=100%Icu- 50 KA, 415 Volts, 1250 Amps ( in replacement) with adjustable thermal and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make :- L&T, Legrand, Scheineiders, Havells, ABB,C&S
MCCBs of following capacities/type/size with adjustable thermal and fixed magnetic setting suitable frame size, 4 Pole,Ics=100%Icu- 415 V, 50 Hz, 3 phase including extension terminals (Spadels) and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, including taking down existing unserviceable one complete all as specified and directed by Engr-in-Charge.
400 amp, 50 kA.
315/320 amp, 35/36 kA.
250 amp, 35/36 kA.
200 amp, 35/36 kA.
160 amp, 35/36 kA.
100 amp, 35/36 kA.
On load change over switch, 4 pole, conforming to IEC 947-3 of following capacities , including Taking down the old U/S change over switches complete all as specified and directed by Engr-in-Charge:- Make:- Havells / L&T/ Schneider
400 Amps, 4 pole
250 Amps, 4 pole
LT change over switch, Off load type, 100 Amps, 4 pole, 50 HZ including Taking down U/S change over switches ,complete all as specified and directed by Engr-in-Charge. Make:- Legrand/ L&T/Havells ,C&S,ABB
1100 Volts grade, heavy duty cable, PVC insulated, stranded, aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 10 Sqmm cable(in replacement) flat or round complete all as specified and directed by Engr-in-Charge.
Surface Dressing/Cleaning of various 33/11 KV sub-stations, free from vegetation of any type, including trimming of tree branches, bushes, creepers, etc. complete all as specified and directed by Engr-in-Charge. Note: The frequency of surface dressing shall not be less than 2 months.
Supply & fixing or laying galvanised steel water tubing, light grade, 100 mm dia (ISI marked) for protection of under ground cable on poles / walls/ under road crossing etc including dismantling & taking down existing unserviceable pipe complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle iron,embedded in PCC 1:2:4, type B-1, blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase, 4 wire, 415 volts, 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. Switchgears shall be measured & paid in the relevent items and same to be fixed by the bcontractor.The panel shall be suitable to accomodate the following equiptments :-
Supply only Change over switch, 630 Amps incomers for distribution conforms to IEC 6097-3/IS 13947-3, Rated Voltages 500V/690V, range having 40A to 2500A, 4 pole complete all as specified and directed by Engr-in-Charge. Make:- Schneider/Havells/Legrand/ L&T
Supply only MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/L&T/ Havells
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle iron,embedded in PCC 1:2:4, type B-1, blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase, 4 wire, 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. Switchgears shall be measured & paid in the relevent items and same to be fixed by the bcontractor.The panel shall be suitable to accomodate the following equiptments :-
Supply only Change over switche,1000 Amps incomers for distribution conforms to IEC 6097-3/IS 13947-3, Rated Voltages 500V/690V, range having 40A to 2500A, 4 pole complete all as specified and directed by Engr-in-Charge. Make:- Schneider/Havells/Legrand/L&T
Supply only MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/ L&T/Havells
Supply only ACB 4 pole , Ics=100%Icu- 50 KA, 415 Volts, 800 Amps , Manual draw out type complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/ L&T/Havells
Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle iron,embedded in PCC 1:2:4, type B-1, blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase, 4 wire, 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. Switchgears shall be measured & paid in the relevent items and same to be fixed by the bcontractor.The panel shall be suitable to accomodate the following equiptments :-
Supply only Change over switch, 400 Amps incomers for distribution conforms to IEC 6097-3/IS 13947-3, Rated Voltages 500V/690V, range having 40A to 2500A, 4 pole complete all as specified and directed by Engr-in-Charge. Make:- Schneider/Havells/Legrand/L&T
Supply only MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/ L&T/Havells
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle iron,embedded in PCC 1:2:4, type B-1, blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase, 4 wire, 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. Switchgears shall be measured & paid in the relevent items and same to be fixed by the by contractor.The panel shall be suitable to accomodate the following equiptments :-
Supply only Change over switch,400 Amps incomers for distribution conforms to IEC 6097-3/IS 13947-3, Rated Voltages 500V/690V, range having 40A to 2500A, 4 pole complete all as specified and directed by Engr-in-Charge. Make:- Schneider/Havells/Legrand/L&T
Supply only MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/ L&T/Havells
Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle iron,embedded in PCC 1:2:4, type B-1, blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase, 4 wire, 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. Switchgears shall be measured & paid in the relevent items and same to be fixed by the bcontractor.The panel shall be suitable to accomodate the following equiptments :-
Supply only Change over switch, 400 Amps incomers for distribution conforms to IEC 6097-3/IS 13947-3, Rated Voltages 500V/690V, range having 40A to 2500A, 4 pole complete all as specified and directed by Engr-in-Charge. Make:- Schneider/Havells/Legrand/L&T
Supply only MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider/ Legrand/ L&T/Havells
Replacement of earthing with Copper earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copper strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, common salt, charcoal dust, 40 mm dia, light grade, GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps ( in replacement) with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
Supply only MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 320 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider Cat No-EZC400H4320N or equivalent in Legrand/ L&T/Havells.
Supply only MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge. Make:- Schneider Cat No-EZC250H4250 or equivalent in Legrand/ L&T/Havells.
vijay kumar gupta and co
FANGALIA TRADERS
MOHAN LAL AND SONS
K S BUILDERS
proach associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .