| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC ALIPURDUAR | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.4 L+₹39,990 (2.85%)Rejected-Finance ALIPURDUAR ALIPURDUAR WEST BENGAL | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹14.6 L+₹57,470 (4.09%)Rejected-Finance ALIPURDUAR WEST BENGAL | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
22 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER COOCHBEHAR ELECTRICAL DIVISION
EXECUTIVE ENGINEER COOCHBEHAR ELECTRICAL DIVISION
WBPWD/EE/CED/e-NIQ-05/2022-23
2022_WBPWD_402030_1
WBPWD/ee/CED/e-NIQ-05/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Alipurduar
Please refer tender documents
6 documents required · 6 mandatory
₹25,000
Yes
5 Jan 2023
5 Sept 2022
26 Sept 2022
5 Sept 2022
22 Sept 2022
5 Sept 2022
Amount
Supply , delivery at site on foundation , commissioning of 100 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure including transportation, loading and unloading of the DG set, having following specifications :-
Engine:- Make : CUMMINS / KOEL GREEN/ MAHINDRA
Engine Type : 4 Stroke Diesel Engine
MoEF certified power : 159 BHP or Higher, Rated Output : 129 BHP or Higher
Duty : PRIME
Cooling : Liquid Cooled (EG Compleat 50:50)
Cylinder : 6
Aspiration : Turbocharged, Charge Air Cooled
Type of Governor : Electronic
Fuel Tank Capacity : As per manufacturer standard.
Fuel Consumption at 75% rated Load with Radiator or Fan : 18.32 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 24.60 Ltr./ Hr.
Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning / Shutdown, High Engine Water Temp. warning / Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low / High Battery Voltage and Weak Battery warning
Alternator Make : Stamford / Leroy Some/ KOEL GREEN
Rating : 415 V., 3Ph. 50 Hz., 100 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF Pane Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 100 KVA DG set having following specification / features.( Customize Panel)
i) 2 No. 200 A AC 3 duty, 4pole power contactor and U/V release etc. [make: ABB, Legrand, Schneider]
ii) 2 Nos. 200 A, 3pole, 35 KA MCCB with microprosser based LSIG protection. [make: Legrand]
iii) In Built By-Pass switch for rated capacity
iv) On -delay timer for load change over
v) On-delay timer for engine shut off
vi) Engine On-Off switch (Push button type)
viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
xi) Microprocessor based relay with composite meter for digital display of following.
Generator voltage / AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
Acoustic Enclosure The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-II norms.
Base Frame Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
Terms & Conditions
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer / OEM.
(vi) The entire set must be warranted at least 15 months from the date of Delivery / 12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years / 5000 Hrs, whichever is earlier.
(vii) During commissioning, the DG set has to be made to run for atleast six hours at a stretch on atleast 75% load at the cost (cost of fuel, operator and technical personnel) of the agency entrusted with the work and the agency will have to provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set. NOTE- If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Making PCC foundation (ratio 1:2:4) of weight 2.5 times of the operating weight of DG set and of approximate depth of 200 mm belowground surface and height of 150mm above ground surface with 3mm thick smooth cement finish to provide leveled surface for placement of the acoustic enclosure. The length and breadth of the platform shall be at least 250mm more than the size of the enclosure. Genset shall be mounted on AVMs inside the enclosure. The platform levels to be checked diagonally as well as across the length for even flatness. The platform shall be within +/-0.5 degree (angle) of any horizontal plane. The contractor shall submit the drawings for approval from the EIC and manufacturer recommendation. before proceeding with the work.
Supply & fixing of exhaust gas piping of suitable dia welded black MS class B pipe incl. all necessary bend supports , clamps, Rain protect Canopy, anti vibration mounting insulation of exhaust system with 50mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for above DG set as per direction of EIC.
S & Delivery of 200 Ltr. Capacity Container made of heavy guage PVC container.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Havells/Polycab/KEI/RR ] 4 Core 70 Sq. mm
Laying one no cable above 35sqmm and upto 185sqmm in underground trench 460mm wide x 760mm avg depth with brick protection on the top of the cable as per GS and also filling the soil levelling up etc.
S&F compression gland with brass glnad, ring & rubber ring for 4core 70 sqmm cable and finishing the ends of the cable with solderless socket (dowels make) with necy tapes, paste and jointing materials
Finishing the end of following XLPE/PVC armored cables by crimping method incl. supplying and fixing solder les socket (Dowels make), tapes, anticorrosive paste & jointing materials. a) 4 core 70 sq mm.
Earthing with 80 mm dia GI pipe (ISI-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Construction of blue scope roofing shade supported onsteel stuucture consisting of atleast 4(four) vertical supports and adequate horizontal support made up of iron pipes with water prof painting on primer, capable of providing protection against rain for the DG having dimension to cover the Genset from weather condition as per specification and as per direction of E.I.C .
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required for 50 mm dia.
M/S DUTTAROY TRADERS
M/S SEN ENTERPRISE
technical_789409.pdf
PDF • 0.37 MB
techsummary_789409.pdf
PDF • 0.20 MB
finance_789409.pdf
PDF • 0.39 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_789409.pdf
PDF • 0.20 MB
AOCBapi.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .