MANAGING DIRECTOR
sugar mill panipat
Stackmonitoring system SPM Analizer and PTZ Camera
2026_HBC_547548_1
Stackmonitoring system SPM Analizer and PTZ Camera
Open Tender
Miscellaneous Goods
Supply
30 days
PANIPAT
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Exempted
23 Sept 2026
14 Sept 2026
21 Sept 2026
14 Sept 2026
21 Sept 2026
14 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation and commissioning of SPM Analyzer(NPL Approved) with PTZ Camera with telemetry system along with data transmission to CPCB/HSPCB Cloud Server for one year complete in all respect as per norms of CPCB/HSPCB.
Sensor for Continuous Stack Emission Monitoring System (OCEMS) with PTZ Camera
Model – System DUSTHUNTER SB30/SP30, Measuring Parameter – SPM, Measured Principle – Forward Light Scattering, Measuring Range – (0 7.5/15/45/75/150/225/375/1,000/3,000 mg/m3), Unit – mg/m3, mg/ Nm3, Process Temp. – Up to 200°C, Ambient Temp. Range – 0°C ... +60°C, Temp. – Up to 200°C, Temp. Measurement – Required for Normalization (mg/nm3), Pressure Measurement – Required for Normalization, Process Gas Humidity – Non-Condensing/Condensing as Per Site, Degree of Protection – Min Requirement IP66, Approval – NPL with Verification Certificate & Long-Life Validity, International Certification – TUV Germany, DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN 15859 (2010), DIN EN 14181 (2014), Product Safety – CE, Accurate Dust Measurement – Yes, DO (RS 485 MODBUS) – Yes, AO (4-20 mA) – Yes, Auto Zero Facility – Yes, Auto Span Facility – Yes, Data Connectivity to CPCB – Yes, Data Connectivity to HSPCB – Yes, Weatherproof Panel – Yes, Display Unit – Yes, Touch Screen
Make- Endress Hauser/Sintrol
Note: We required this NPL Certified Sensor for Continuous Stack Emission Motoring System with installation of PTZ Camera also as per CPCB Guidelines. Rate Should be inclusive of Installation/Erection and Commissioning.
Bidder also responsible for transfer stack data on CPCB/HSPCB server. | 1 | No | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.11 MB
BOQ_627222.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .