| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹32.3 L+₹3.3 L (11.4%)Rejected-AOC NO 228 3RD CROSS HRBR 3RD BLOCK NEAR JALVAYU VIHAR WEST GATE BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹35.5 L+₹6.5 L (22.2%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹37.0 L+₹8.0 L (27.6%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹37.6 L+₹8.6 L (29.6%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-AOC Higher bid value |
Tender Value
Refer Docs
EMD Value
₹91,520
Closing Date
13 Jun 2025, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR/MAINTENANCE TO LT PANEL LT CABLES MCCBs AND CONNECTED WORKS AT POCKET I AND II CHAF BANGALORE
2025_MES_708567_1
8340/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹91,520
2 Jul 2025
16 May 2025
16 Jun 2025
16 May 2025
13 Jun 2025
30 May 2025
17 May 2025 - 23 May 2025
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth and getting out in soft /loose soil for laying of cable complete all as specified and as directed by Engr-in-charge.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm complete all as specified and as directed by Engr-in-charge.
Removal of surplus soil (excavated soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for river sand, spread dry in trenches as in cable cushioning complete all as specified and as directed by Engr-in-charge. Note: Only punned thickness shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover class LV, type 1, flat, size 250x150x40mm laid in trenches as in protection of UG cables complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of straight through joints heat shrink type suitable for 10 to 16 sqmm of 3.5/4 core sizes of PVC/XLPE insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits complete for making joints complete all as specified and as directed by Engr-in-charge.
All as per item No.06 here-in-before but for 25 to 50 sqmm of 3.5/4 core.
All as per item No.06 here-in-before but for 70 to 150 sqmm of 3.5/4 core.
All as per item No.06 here-in-before but for 240 to 300 sqmm of 3.5/4 core.
Taking up or down unserviceable steel tubing and connections of sizes 50/80mm or above complete all as specified and as directed by Engr-in-charge.
Supply and fix for GI tubing light grade 50mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for GI tubing light grade 80mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for boring of holes under road pavement hard standing by manual boring including making good the disturbed surfaces complete all as specified and as directed by Engr-in-charge.
Taking up /down old unserviceable UG cable of any size complete all as specified and as directed by Engr-in-charge.
Material and labour for LT UG cable 4 core x 16 sqmm 1100 volts grade XLPE insulated, flat steel armoured, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete including taking down existing LT UG cable of any size complete all as specified and as directed by Engr-in-charge. Notes: (i) Excavation earth work and sand cushioning brick protection and connected work etc., shall be measured and paid separately under relevant item of schedule. (ii) Rate quoted deemed to include for cutting and removing of defective joints wherever required as directed.
All as per Item No.15 here-in-before but for 3.5 core x 25 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 35 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 50 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 70 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 95 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 120 sqmm.
All as per Item No.15 here-in-before but for 3.5 core x 240 sqmm.
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape unarmoured with galvanised steel tape and overall PVC sheathed 10 sqmm, 2 core nominal cross section in service connections complete all as specified and as directed by Engr-in-charge.
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape unarmoured with galvanised steel tape and overall PVC sheathed 10 sqmm, 4 core nominal cross section in service connections complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 16 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 25 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 35 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 50 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 70 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 95 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 120 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium cable lugs of size 240 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 16 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 25 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 35 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 50 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 70 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 95 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 120 sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement aluminium in-line connectors of size 240 sqmm complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 pole, 415 volts, 63 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 pole, 415 volts, 100 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCCB, 4 poles 415 Volts, 350 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of power contactor, 3/4 pole, 415 Volts, 265 Amps, 50 Hz, AC fixed in the existing ATS LT panel board including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of power contactor, 3/4 pole, 415 Volts, 315/330 Amps, 50 Hz, AC fixed in the existing ATS LT panel board including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacment of ON LOAD change over switch with sheet metal enclosure 415V, 4 pole of capacity 250 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacment of ON LOAD change over switch with sheet metal enclosure 415V, 4 pole of capacity 315/320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of sheet metal enclosure made out of 2mm thick CRCA sheet duly powder coated suitable for fixing /mounting MCCB of 160 Amps 4 pole duly fixed on wall with all fixing arangements complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of sheet metal enclosure made out of 2mm thick CRCA sheet duly powder coated suitable for fixing /mounting MCCB of 250 Amps 4 pole duly fixed on wall with all fixing arangements complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of MCB TPN 63 A, 'C' Curve, 10 KA rupturing capacity complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of MCB TPN 40 A, 'C' Curve, 10 KA rupturing capacity complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of MCB TPN 100 A, 'C' Curve, 10 KA rupturing capacity complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of RCCB 63 Amps TPN, 'C' Curve, 10 KA rupturing capacity having sensitivity 30mA complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of RCCB 100 Amps TPN, 'C' Curve, 10 KA rupturing capacity having sensitivity 30mA complete all as specified and as directed by Engr-in-charge.
Material and labour for cleaning, dusting and servicing LT panel, MCCBs, Bus bars tightening cable connections, replacing of worn out parts such as busbar spout suppourts, spacers, hinges, locks, glands and connected items/ mechanical parts etc., for its smooth functioning including applying becktrol red solution to the surface of the bus bars and spouts, applying monoplast compound at the bus bar joints after tightening of joints, cleaning the disturbed area beneath the LT panel and removing vegitation, debris etc., complete all as specified and as directed by Engr-in-charge. Note: Quoted rate deemed to include for removing and replacing of defective items such as insulators for busbar, separators, sleeves, hinges, bolts, nuts wherever required.
Material and labour for servicing of ACB 800/1200A rating by disconnecting and taking out the breaker after taking power shutdown of the respective panel and overhauling/ servicing the ACB by opening all parts and cleaning of electrical contacts with CTC/ rust remover, lubricating electrical moving parts with petrolium jelly and mechanical moving parts with grease and applying becktrol red solution to the surface of the bus bars and spouts, applying monoplast compound at the bus bar joints after tightening of joints and replacing defective spare parts like springs/ bolts/ nuts/ washers etc., including testing, calibrating, refixing the circuit breaker and make fuctional complete all as specified and as directed by Engr-in-charge.
Material and labour for painting the LT panel complete of any capacity after preparation of surface and applying two coats of synthetic enamel (smoke grey) paint and old steel surafce, replace the danger notice plate complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of APFC microcontroller relay 8 steps fixed to existing APFC panel including taking down the existing unserviceable relay complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of capacitor duty APFC contactor suitable to switching 15 KVAR capacitor, 3 pole, 415V rating fixed to existing capacitor bank by taking down the existing unserviceable contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of capacitor duty APFC contactor suitable to switching 20 KVAR capacitor, 3 pole, 415V rating fixed to existing capacitor bank by taking down the existing unserviceable contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power factor capacitors MPPH type of 5 KVAR rating, fixed to existing capacitor bank including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power factor capacitors MPPH type of 25 KVAR rating, fixed to existing capacitor bank including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power factor capacitors MPPH type of 20 KVAR rating, fixed to existing capacitor bank including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power factor capacitors MPPH type of 10 KVAR rating, fixed to existing capacitor bank including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of APFC copper HD harmonic reactor having Class 'H' insulation, low noise, low losses and high harmonic loading capability of 10 KVAR rating, 440V, fixed to existing APFC panel including taking down the existing unserviceable reactor and connecting up and including testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of APFC copper HD harmonic reactor having Class 'H' insulation, low noise, low losses and high harmonic loading capability of 12.5 KVAR rating, 440V, fixed to existing APFC panel including taking down the existing unserviceable reacter and connecting up and including testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of digital multifunctional panel meter for measuring voltage (0-500V min), current, PF, etc., including necessary PT and CT's with all connected acccessories complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of digital voltmeters 0-500V, with all connected accessories including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of digital ammeter 0-600A (min), with CT's, all connected accessories including connecting up and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of LED indicator lamp 240 V, with suitable colour Red /Blue /Yellow /Amber /Green and connected acccessories complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of push button switch with NO/NC contacts 415 V, 6A, with add on Aux contacts and connected acccessories complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power contactor AC coil 240V, 50 Hz suitable for MNX 70 contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power contactor AC coil 240V, 50 Hz suitable for MNX110/95/140 contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power contactor AC coil 240V, 50 Hz suitable for MNX300/MNX400 contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of power contactor AC coil 240V, 50 Hz suitable for MCX40/25/32 contactor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacment of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 250A, 4 way aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed by Engr-in-charge. Note: Quoted rate shall be inclusive for excavation, earth work and PCC work and complete connected work.
Supply and fix in replacment of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 400A, 6 way aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed by Engr-in-charge. Note: Quoted rate included for excavation, earth work and PCC work and complete connected work.
Supply and fix in replacment of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 800A, 6 way aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed by Engr-in-charge. Note: Quoted rate included for excavation, earth work and PCC work and complete connected work.
Supply and fix in replacement of saftey protection relay 415V AC, 3 Phase, 4 wire, 2 C/O with adjustable under voltage, over voltage, on delay, neutral fail protection for LT panel complete all as specified and as directed by Engr-in-charge.
Material and labour for repair /reconditioning of exisitng earth pit by removing damaged earth PCC chambers and excavated pit soil upto 25% of earth plate /electrode and adding alternate layers of charcoal, mixture of salt and copper sulphate upto 15cm above the earth plate /electrode and moist the mixture using water, cleaning /replacing of funnel with wire mesh where ever necessary, testing the earthing after reconditioning and earth resistance value must be within 1.5 Ohms, making good to distrubed surface complete all as specified and as directed by Engr-in-charge. Notes: (i) Quoted rate shall be including for excavation, returning filling and connected items. (ii) Salt, Charcoal, Copper Sulphate, Pit Chamber, Testing will be measured and paid seperatly.
Supply only pure charcoal granular/aggregate type having Ash content < 5%, stone free for earthing complete all as specified and as directed by Engr-in-charge.
Supply only iodine free pure common salt crystal (NaCl) for earthing complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement for laying earth continuity conductor GI strip 25x4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct /loop earthing with proper PVC/ porcelain insulator etc., complete all as specified and as directed by Engr-in-charge.
Material and labour in repair/ replacement of damaged earth chamber with premoulded PCC earth chamber with cast iron cover of size 300x300x50mm including provision of funnel, wire mesh necessary excavation and earth work in any type of soil including painting, marking of earth values with date complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of PVC polymer insulator for existing GI/ Aluminium/ copper strip support complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth strip of size 25x4mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No.3 of SSR part 1, connected to DB/ earthing test point including PCC chamber, RCC cover 50mm thick with 8mm dia bars, protection pipe, funnel etc., including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40mm bore light grade upto 7.5m including testing on completion complete all as specified and as directed by Engr-in-charge.
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4 Mpa working pressure complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth strip of size 32x6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No.3 of SSR part 1, connected to DB/ earthing test point including PCC chamber, RCC cover 50mm thick with 8mm dia bars, protection pipe, funnel etc., including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40mm bore light grade upto 7.5m including testing on completion complete all as specified and as directed by Engr-in-charge.
Material and labour for loose filling with aggregates of gauge 40mm filling in panel surrounding upto 1 to 3m as per ground availability of area, cleaning the area, making level, and filling the aggregate complete all as specified and as directed by Engr-in-charge.
Material and labour for testing of earthing resistance of existing earthing using calibrated 3/4 wire digital earth resistance tester and recording the earth resistance value in register obtaining the signature of user and MES executive after varification complete all as specified and as directed by Engr-in-charge. Note: Contractor has to provide digital earth resistance tester and should be available all the time during the contract period.
S SELVALAKSHMI ENGINEER AND CONTRACTOR (BID ID -3312653)
RRK PROJECTS (BID ID -3322531)
M/S - KRUPA ELECTRICALS (BID ID -3314651)
M/s BHOOMI ELECTRICALS (BID ID -3322128)
M/S J S PRAKASAM (BID ID -3312966)
Pacific Enterprises (BID ID -3312096)
SREE VARU ELECTRICALS (BID ID -3315389)
GKR and CO (BID ID -3322192)
kamadhenu Electricals (BID ID -3314875)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .